Title: Unfolding Textile-Based Pneumatic Actuators for Wearable Applications
Textile based pneumatic actuators have recently seen increased development for use in wearable applications thanks to their high strength to weight ratio and range of achievable actuation modalities. However, the design of these textile-based actuators is typically an iterative process due to the complexity of predicting the soft and compliant behavior of the textiles. In this work we investigate the actuation mechanics of a range of physical prototypes of unfolding textile-based actuators to understand and develop an intuition for how the geometric parameters of the actuator affect the moment it generates, enabling more deterministic designs in the future. Under benchtop conditions the actuators were characterized at a range of actuator angles and pressures (0 – 136 kPa), and three distinct performance regimes were observed, which we define as Shearing, Creasing, and Flattening. During Flattening, the effects of both the length and radius of the actuator dominate with maximum moments in excess of 80 Nm being generated, while during Creasing the radius dominates with generated moments scaling with the cube of the radius. Low stiffness spring like behavior is observed in the Shearing regime, which occurs as the actuator approaches its unfolded angle. A piecewise analytical model was also developed and compared to the experimental results within each regime. Finally, a prototype actuator was also integrated into a shoulder assisting wearable robot, and on-body characterization of this robot was performed on five healthy individuals to observe the behavior of the actuators in a wearable application. Results from this characterization highlight that these actuators can generate useful on-body moments (10.74 Nm at 90° actuator angle) but that there are significant reductions compared to bench-top performance, in particular when mostly folded and at higher pressures.  more » « less
Award ID(s):
2011754
PAR ID:
10499807
Author(s) / Creator(s):
; ; ; ;
Publisher / Repository:
Mary Ann Liebert Publishers
Date Published:
Journal Name:
Soft Robotics
Volume:
9
Issue:
1
ISSN:
2169-5172
Page Range / eLocation ID:
163 to 172
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Accurate and interpretable models are essential for understanding actuator behavior and enabling effective design and control of soft wearable robotics. We present the experimental analysis and data‐driven modeling of soft pneumatic actuators designed to assist upper‐extremity motion in a pediatric exosuit. Experiments used an infant‐sized upper‐body test rig equipped with load cells and joint encoders to collect force and angle data. Four soft pneumatic actuators, two for the shoulder (1‐cell and 2‐cell rectangular actuators) and two for the elbow (bellow‐type actuators with square and circular cells), were selected based on workspace and motion profile smoothness. Each actuator was tested independently, with one joint actuated per trial across multiple anchoring configurations and passive joint angles to explore how these influence the actuated joint angles and generated forces. Three data‐driven approaches, segmented polynomial, segmented sigmoid, and autoregressive model with exogenous input (ARX), were used to model the relationship between pressure, joint angle, and force. The ARX model provided the most accurate and comprehensive representation by incorporating temporal information, whereas the sigmoid and polynomial models captured saturation and overall trends, respectively. These findings provide a basis for selecting modeling strategies suited to specific actuators and control needs, and support actuator design and model‐based control. 
    more » « less
  2. This paper investigates the tradeoffs between design variables important for the development of a mobility support soft exoskeleton for horizontal shoulder adduction. The soft exoskeleton utilizes discreet shape memory alloy (SMA) spring actuators to generate the required torque to move the arm segment, while preserving the qualities of a soft, wearable garment solution. A pilot benchtop test involving varying power input, actuator anchor position, actuator orientation, and added weight, was investigated to evaluate their effects against the degree of motion the soft exoskeleton allows. The results show that the power input, actuator anchor position, and simulated limb weight each affect the ultimate horizontal adduction angle the exoskeleton is able to induce. Further, the project highlights a crucial point in regard to the tradeoffs between functionality and wearability: when actuator orientation was investigated, we found a decrement in functionality (as measured by maximum achievable horizontal adduction angle) when the actuators were constrained close to the body. This shows that when aiming to improve the hypothetical system’s wearability/usability, the effective torque that can be generated is reduced. Together these findings demonstrate important design considerations while developing a wearable, soft exoskeleton system that is capable of effectively supporting movement of the body while maintaining the comfort and discreetness of a regular garment. 
    more » « less
  3. This paper will investigate the effects of pennate angle on fluidic artificial muscle (FAM) bundles for a robot arm motion. Rising interest in soft fluidic actuators exists due to their prospective inherent compliance and safe human-robot interaction. The high force-to-weight ratio, innate flexibility, inexpensive construction, and muscle-like force-contraction behavior of McKibben FAMs make them an attractive type of soft fluidic actuator. Multi-unit architectures found in biological muscles tissues and geometric fiber arrangements have inspired the development of hierarchical actuators to enhance the total actuator performance and increase actuator functionality. Parallel, asymmetric unipennate, and symmetric bipennate are three muscle fiber arrangement types found in human skeletal muscle tissues. Unique characteristics of the pennate muscle tissue, with muscle fibers arranged obliquely from the line of muscle motion, enable passive regulation of effective transmission between the fibers and muscle. Prior studies developed an analytical model based on idealized assumptions to leverage this pennate topology in optimal fiber parameter design for FAM bundles under spatial bounds. The findings showed FAMs in the bipennate topology can be designed to amplify the muscle output force, contraction, and stiffness as compared to that of a parallel topology under equivalent spatial and operating constraints. This work seeks to extend upon previous studies by investigating the effects of pennate angle on actuation and system hydraulic efficiency for a robot arm with a more realistic FAM model. The results will progress toward tailoring actuator topology designs for custom compliant actuation applications. 
    more » « less
  4. null (Ed.)
    Abstract This review meta-analysis combines and compares the findings of previously published works in the field of soft wearable robots (SWRs) that provide active methods of actuation for assistive and augmentative purposes. A thorough investigation of major contributions in the field of an SWR is made to analyze trends in the field focused on fluidic and cable-driven systems, prevalent and successful approaches, and identify the future direction of SWRs and active actuation strategies. Types of soft actuators used in wearables are outlined, as well as general practices for fabrication methods of soft actuators and considerations for human–robot interface designs of garment-like exosuits. An overview of well-known and emerging upper body (UB)- and lower body (LB)-assistive technologies is categorized by the specific joints and degree of freedom (DoF) assisted and which actuator methodology is provided. Different use cases for SWRs are addressed, as well as implementation strategies and design applications. 
    more » « less
  5. Sensing and actuation are intricately connected in soft robotics, where contact may change actuator mechanics and robot behavior. To improve soft robotic control and performance, proprioception and contact sensors are needed to report robot state without altering actuation mechanics or introducing bulky, rigid components. For bioinspired McKibben-style fluidic actuators, prior work in sensing has focused on sensing the strain of the actuator by embedding sensors in the actuator bladder during fabrication, or by adhering sensors to the actuator surface after fabrication. However, material property mismatches between sensors and actuators can impede actuator performance, and many soft sensors available for use with fluidic actuators rely on costly or labor-intensive fabrication methods. Here, we demonstrate a low-cost and easy-to manufacture-tubular liquid metal strain sensor for use with soft actuators that can be used to detect actuator strain and contact between the actuator and external objects. The sensor is flexible, can be fabricated with commercial-off-the-shelf components, and can be easily integrated with existing soft actuators to supplement sensing, regardless of actuator shape or size. Furthermore, the soft tubular strain sensor exhibits low hysteresis and high sensitivity. The approach presented in this work provides a low-cost, soft sensing solution for broad application in soft robotics. 
    more » « less