- Award ID(s):
- 1841558
- PAR ID:
- 10519023
- Publisher / Repository:
- MDPI
- Date Published:
- Journal Name:
- Sensors
- Volume:
- 23
- Issue:
- 17
- ISSN:
- 1424-8220
- Page Range / eLocation ID:
- 7627
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
null (Ed.)To increase the production of crops, chemical fertilizers are used in crop fields. However, underuse or overuse cannot increase crop yields but even decrease them and cause severe environmental problems. Thus, the detection and monitoring of chemical concentration are increasingly important. To build up and monitor a data-based system for a large area, such a method is costly and time-consuming. In this research, we developed a conductive polymer-based sensor to detect nitrate concentrations in soil water. Conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) was used as our sensing material. To increase its conductivity, we used the vacuum phase polymerization method to achieve a high conductive and stable polymer film. The conductivity of the polymer film is 500 S/cm. Our results have demonstrated that the conductive polymer-based sensors have high sensitivity to nitrate solution. The response to 1000 ppm nitrate solution is 47.2% (Response = (Initrate - IDIwate) / IDIwater). The sensors can detect nitrate range from 1ppm to 1000 ppm. The response time is less than 1 minute. This impedance-based sensor will eventually be integrated with the surface acoustic wave sensors, combined with an antenna and a GPR unit for low maintenance, autonomous, and in-situ soil nutrient sensing.more » « less
-
null (Ed.)To increase the production of crops, chemical fertilizers are used in crop fields. However, underuse or overuse cannot increase crop yields but even decrease them and cause severe environmental problems. Thus, the detection and monitoring of chemical concentration are increasingly important. To build up and monitor a data-based system for a large area, such a method is costly and time-consuming. In this research, we developed a conductive polymer-based sensor to detect nitrate concentrations in soil water. Conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) was used as our sensing material. To increase its conductivity, we used the vacuum phase polymerization method to achieve a high conductive and stable polymer film. The conductivity of the polymer film is 500 S/cm. Our results have demonstrated that the conductive polymer-based sensors have high sensitivity to nitrate solution. The response to 1000 ppm nitrate solution is 47.2% (Response = (Initrate - IDIwate) / IDIwater). The sensors can detect nitrate range from 1ppm to 1000 ppm. The response time is less than 1 minute. This impedance-based sensor will eventually be integrated with the surface acoustic wave sensors, combined with an antenna and a GPR unit for low maintenance, autonomous, and in-situ soil nutrient sensingmore » « less
-
Abstract Current potentiometric sensing methods are limited to detecting nitrate at parts-per-billion (sub-micromolar) concentrations, and there are no existing potentiometric chemical sensors with ultralow detection limits below the parts-per-trillion (picomolar) level. To address these challenges, we integrate interdigital graphene ion-sensitive field-effect transistors (ISFETs) with a nitrate ion-sensitive membrane (ISM). The work aims to maximize nitrate ion transport through the nitrate ISM, while achieving high device transconductance by evaluating graphene layer thickness, optimizing channel width-to-length ratio (
R WL), and enlarging total sensing area. The captured nitrate ions by the nitrate ISM induce surface potential changes that are transduced into electrical signals by graphene, manifested as the Dirac point shifts. The device exhibits Nernst response behavior under ultralow concentrations, achieving a sensitivity of 28 mV/decade and establishing a record low limit of detection of 0.041 ppt (4.8 × 10−13M). Additionally, the sensor showed a wide linear detection range from 0.1 ppt (1.2 × 10−12M) to 100 ppm (1.2 × 10−3M). Furthermore, successful detection of nitrate in tap and snow water was demonstrated with high accuracy, indicating promising applications to drinking water safety and environmental water quality control. -
The concentration of nitrate (NO3−) in Narragansett Bay has been shown to undergo considerable temporal and spatial variation. However, the dynamics of this flux has never been monitored on a fine-scale (<100 m, < 1 d) or in real-time. Whole-cell bio-reporters are promising candidates for low cost environmental sensing of bioavailable nutrients. Yet difficulties remain in creating sensors for long term deployment in the marine environment. This paper describes the creation and validation of a low-cost sensor using a self-bioluminescent strain of the cyanobacteria Synechococcus elongatus pcc 7942 for the direct measurement of bioavailable nitrate. Nitrate bioavailability was measured by monitoring light emission from a luxAB based promotor fusion to glnA using a light to frequency sensor and single board microcontroller. Sensor designs are presented in this manuscript with specific focus on storage, cell viability, and compatibility with the marine environment. Sensors were able to consistently assess nitrate standards as low as 1 ppm (16.3 μM). Using a wavelet denoising approach to reduce white noise and hardware noise, nitrate detection of standards as low as 0.037 ppm (0.65 μM) was achieved. Good sensitivity and low cost make these sensors ideal candidates for continuous monitoring of biological nitrates in estuarine systems.more » « less
-
null (Ed.)The effect of UV illumination on the room temperature electrical detection of ammonium nitrate vapor was examined. The sensor consists of a self-assembled ensemble of silica nanosprings coated with zinc oxide. UV illumination mitigates the baseline drift of the resistance relative to operation under dark conditions. It also lowers the baseline resistance of the sensor by 25% compared to dark conditions. At high ammonium nitrate concentrations (120 ppm), the recovery time after exposure is virtually identical with or without UV illumination. At low ammonium nitrate concentrations (20 ppm), UV illumination assists with refreshing of the sensor by stimulating analyte desorption, thereby enabling the sensor to return to its baseline resistance. Under dark conditions and low ammonium nitrate concentrations, residual analyte builds up with each exposure, which inhibits the sensor from returning to its original baseline resistance and subsequently impedes sensing due to permanent occupation of absorption sites.more » « less