Title: Strut-and-Tie Method for GFRP-RC Deep Members
Abstract The current code provisions in ACI 440.11 are based on the flexural theory that applies to slender members and may not represent the actual structural behavior when the shear span-to-reinforcement depth ratio is less than 2.5 (i.e., deep members). The Strut-and-tie method (STM) can be a better approach to design deep members; however, this chapter is not included in the code. Research has shown that STM models used for steel-reinforced concrete (RC) give satisfactory results when applied to glass fiber-reinforced polymer-reinforced (GFRP)-RC members with a/d less than 2.5. Therefore, this study is carried out to provide insights into the use of STM for GFRP-RC deep members based on the available literature and to highlight the necessity for the inclusion of a new chapter addressing the use of STM in the ACI 440.11 Code. It includes a design example to show the implications of ACI 440.11 code provisions when applied to GFRP-RC deep members (i.e., isolated footings) and compares it when designed as per STM provided in ACI 318-19. It was observed that current code provisions in ACI 440.11 required more concrete thickness (i.e.,h = 1.12 m) leading to implementation challenges. However, the required dimensions decreased (i.e.,h = 0.91 m) when the design was carried out as per STM. Due to the novelty of GFRP reinforcement, current code provisions may limit its extensive use in RC buildings, particularly in footings given the water table issues and excavation costs. Therefore, it is necessary to adopt innovative methods such as STM to design GFRP-RC deep members if allowed by the code.  more » « less
Award ID(s):
1916342
PAR ID:
10522541
Author(s) / Creator(s):
;
Publisher / Repository:
Springer Science + Business Media
Date Published:
Journal Name:
International Journal of Concrete Structures and Materials
Volume:
18
Issue:
1
ISSN:
2234-1315
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract The current provisions for development length in the ACI 440.11 code disregard the confinement effect provided by stirrups on the bond strength of longitudinal bars and require splice lengths that pose implementation challenges. Given the significant improvement in GFRP material properties, this study investigated the bond strength of sand-coated GFRP bars and proposed a new factor to include the effect of stirrup confinement on the bond-strength provisions. The experimental program involved 16 GFRP-reinforced concrete (RC) beams having a width of 300 mm, and depth 440 mm, consisting of two repetitions for every configuration, subjected to four-point loading. The test parameters comprised lap-splice length and stirrup spacing in the lap-spliced zone. Out of 16 GFRP-RC beams, two beams were reinforced with two M16 (No. 5) continuous bars and six with varying lap-splice lengths [i.e., 40, 60, and 80 bar diameters (db)] without confining stirrups. To evaluate the effect of confining stirrups, eight beams were reinforced with two M16 (No. 5) lap-spliced longitudinal bars (i.e., 40 and 60 db) and M13 (No. 4) stirrups spaced at 100 mm (4 in.) and 200 mm (8 in.) center-to-center. Based on experimental results, stirrup confinement clearly increased the bond strength, reduced longitudinal bar slippage, and increased splitting stress. The beams with a splice length of 60 dband stirrups on 100 mm (4 in.) centers achieved 57% higher capacity than those with the same lap-splice length but without stirrups. Further, the ACI 440.11 equation overestimated the bond strength of sand-coated GFRP bars but yielded conservative results with closely spaced stirrups. CSA S6:25 predicted bond-strength values that were close to the experimental results compared to CSA S6:19, and CSA S806:12. 
    more » « less
  2. Fiber reinforced polymer (FRP) waste is becoming an environmental concern due to the widespread use and non-biodegradable nature of FRP composites. Cutting FRP waste into discrete reinforce-ments (referred to as “needles” hereafter) as coarse aggregate in concrete has been suggested as a possible solution to FRP waste recycling. It has previously been observed in small specimens that FRP needles increase the tensile strength and energy absorption capacity of concrete. This paper presents an experimental investiga-tion into the effect of GFRP needles as coarse aggregate partial replacement in concrete on shear behavior of full-scale reinforced concrete (RC) beams. A total of 10 RC beams without steel stirrups in the critical zone were tested under four-point bending. The volume replacement ratio of the coarse aggregate and the surface type of GFRP needles were chosen as the test parameters. GFRP needles, with either smooth or helically wrapped surfaces, were added to the concrete mix to replace 5% or 10% of coarse aggregate by volume, respectively. All test beams failed in shear in a brittle manner with the ductility being slightly enhanced by the partial replace-ment of coarse aggregate using GFRP needles. An enhancement of 8%-10% in the load carrying capacity was observed in beams with helically wrapped needles, while beams with smooth needles showed a reduction in the load carrying capacity. 
    more » « less
  3. Abstract Glass fiber reinforced polymer (GFRP) bars are composite materials that, in the field of civil engineering, serve as an alternative for the internal steel reinforcement of concrete structures. The study and development of these material systems in construction are relatively new, requiring targeted research and development to achieve greater adoption. In this scenario, research and standardization play crucial roles. The development and publication of new test methods, material specifications, and other standards, as well as the improvement of the existing ones, allow for quality control, validation, and acceptance. One of these improvements is the evaluation of precision statements of the different ASTM standards related to the physical-mechanical and durability characterization of GFRP bars used as internal concrete reinforcement. Precision refers to how closely test results obtained under specific conditions agree with each other. A precision statement allows potential users to assess the test method’s general suitability for their intended applications. It should provide guidance on the type of variation that can be expected between test results when the method is used in one or more competent laboratories. The present study aims to enhance the precision statements in ASTM standards pertaining to the geometric, material, mechanical, and physical properties required for GFRP bars in concrete reinforcement, including ASTM standards like ASTM D7205M-21, Standard Test Method for Tensile Properties of Fiber Reinforced Polymer Matrix Composite Bars; ASTM D7617M-11(2017), Standard Test Method for Transverse Shear Strength of Fiber-Reinforced Polymer Matrix Composite Bars; and ASTM D7913M-14(2020), Standard Test Method for Bond Strength of Fiber-Reinforced Polymer Matrix Composite Bars to Concrete by Pullout Testing, while in accordance with the statistical procedures and calculation methods outlined in ASTM Practices ASTM E177-20, Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods, and ASTM E691-22, Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method. 
    more » « less
  4. Abstract Glass fiber-reinforced polymers (GFRP) are widely applied to enhance the strength of concrete columns due to their lightweight and high-strength characteristics. This study presents the development of a metaheuristics-guided machine learning (ML) model for predicting the compressive strength (CS) of GFRP-confined concrete columns (GFRP-CC). Traditional predictive models, primarily based on Linear or nonlinear regression, are often limited by narrow data scopes and methodological constraints. To address this gap, we propose an innovative ML model, leveraging an extensive database of 319 experimental results compiled from 41 peer-reviewed articles spanning 1991–2024. Using an artificial neural network (ANN) combined with five metaheuristic algorithms, the study aims to reduce the dependency on costly and time-intensive laboratory testing. The model development considered eight key parameters: diameter of the compression member (D), height of the compression member (H), compressive strength of unconfined concrete (f′co), GFRP reinforcement ratio (ρf), tensile modulus of elasticity of GFRP (Ef), ultimate tensile strength of GFRP (ff), nominal thickness of GFRP reinforcement (tf), and number of GFRP layers. Among the tested models, the Stochastic Paint Optimizer (SPO)-ANN model demonstrated the highest accuracy, achieving a coefficient of determination of 0.9630 with minimal error values. To ensure transparency and interpretability, SHapley Additive exPlanations (SHAP), Olden methodologies, and Partial dependence were employed to elucidate the relative importance of contributing features. Critical factors influencing the CS of GFRP-CC included the thickness of GFRP reinforcement, tensile strength, and layer count. A user-friendly graphical interface was developed to facilitate practical adoption, enabling researchers and practitioners to model CFRP-CC compressive strength efficiently. This work represents a paradigm shift in concrete research, emphasizing sophisticated, data-driven methodologies that bridge the gap between experimental data and practical applications. 
    more » « less
  5. Recycling glass fiber reinforced polymer (GFRP) composite materials has been proven to be challenging due to their high mechanical performance and high resistance to harsh chemical and thermal conditions. This work discusses the efforts made in the past to mechanically process GFRP waste materials by cutting them into large-sized (cm scale) pieces, as opposed to pulverization, for use in concrete mixtures. These pieces can be classified into two main categories—coarse aggregate and discrete reinforcement, here referred to as “needles.” The results from all the studies show that using GFRP coarse aggregate leads to significant reductions in the compressive strength and tensile strength of concrete. However, GFRP needles lead to sizable increases in the energy absorption capacity of concrete. In addition, if the glass fibers are longitudinally aligned within the needles, these elements can substantially increase the tensile strength of concrete. Processing GFRP waste into needles requires less energy and time than that for producing GFRP coarse aggregate. Also, compared to pulverized GFRP waste, which consists of broken and separate particles of glass and resin that at best can be used as low-quality fillers, GFRP needles are high strength composite elements 