Submarine cables have become a vital component of modern infrastructure, but past submarine cable natural hazard studies have mostly focused on potential cable damage from landslides and tsunamis. A handful of studies examine the possibility of space weather effects in submarine cables. The main purpose of this study is to develop a computational model, using Python , of geomagnetic induction on submarine cables. The model is used to estimate the induced voltage in the submarine cables in response to geomagnetic disturbances. It also utilizes newly acquired knowledge from magnetotelluric studies and associated investigations of geomagnetically induced currents in power systems. We describe the Python-based software, its working principle, inputs/outputs based on synthetic geomagnetic field data, and compare its operational capabilities against analytical solutions. We present the results for different model inputs, and find: 1) the seawater layer acts as a shield in the induction process: the greater the ocean depth, the smaller the seafloor geoelectric field; and 2) the model is sensitive to the Ocean-Earth layered conductivity structure.
more »
« less
An Examination of Geomagnetic Induction in Submarine Cables
Abstract Submarine cables have experienced problems during extreme geomagnetic disturbances because of geomagnetically induced voltages adding or subtracting from the power feed to the repeaters. This is still a concern for modern fiber‐optic cables because they contain a copper conductor to carry power to the repeaters. This paper provides a new examination of geomagnetic induction in submarine cables and makes calculations of the voltages experienced by the TAT‐8 trans‐Atlantic submarine cable during the March 1989 magnetic storm. It is shown that the cable itself experiences an induced electromotive force (emf) and that induction in the ocean also leads to changes of potential of the land at each end of the cable. The process for calculating the electric fields induced in the sea and in the cable from knowledge of the seawater depth and conductivity and subsea conductivity is explained. The cable route is divided into 9 sections and the seafloor electric field is calculated for each section. These are combined to give the total induced emf in the cable. In addition, induction in the seawater and leakage of induced currents through the underlying resistive layers are modeled using a transmission line model of the ocean and underlying layers to determine the change in Earth potentials at the cable ends. The induced emf in the cable and the end potentials are then combined to give the total voltage change experienced by the cable power feed equipment. This gives results very close to those recorded on the TAT‐8 cable in March 1989.
more »
« less
- Award ID(s):
- 1935110
- PAR ID:
- 10522740
- Publisher / Repository:
- AGU
- Date Published:
- Journal Name:
- Space Weather
- Volume:
- 22
- Issue:
- 2
- ISSN:
- 1542-7390
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
By fusing data obtained from finely spaced continental-scale, magnetotelluric (MT) measurements used for geophysical imaging of the electrical conductivity variations of the Earth's crust and mantle, real-time data of the geomagnetic field variations at a sparse network of fixed geomagnetic observatory and variometer stations, power transmission system sensor data such as neutral ground return current, synchrophasor and other sensor data, information on power grid topology and state, and by applying algorithms we have developed to project the real-time stream of magnetic observatory and variometer data through the frequency-dependent tensor impedances derived from the MT data at each temporary station, we calculate the anomalous voltages on power transmission substations induced by geomagnetically induced currents. Our solution accounts for the first-order impacts on the induced voltages that are due to the effects of 3-D variations in ground (Earth's crust and upper mantle) electrical conductivity structure. These effects when convolved with the path integral of the induced vector ground electric field along the transmission lines are the dominant term in determining the intensity of the geomagnetically induced currents in the system; considerably more so than geomagnetic latitude scaling effects. We discuss integration of real-time geophysical estimates of geomagnetic disturbance induced substation voltages with DC and AC power flow simulations on increasingly realistic models of the topology and state of regional power grids. We are integrating our workflow with the open source PowerModelsGMD.jl power flow simulator developed at Los Alamos National Laboratory, and describe simulations of real-time assessments of stress on critical assets of the power grid including reactive power loss, phase deviations, transformer heating and other metrics of transmission system stress. Such efforts to provide a real-time assessment of risk to critical assets can also inform statistical assessments of system vulnerabilities to "100-yr" or "Carrington" level geomagnetic disturbances. We will discuss how such efforts are informing the development of updated standards that may impact the future regulatory environment that governs efforts to maintain a resilient power transmission system.more » « less
-
Abstract Geophysical sensing in the open ocean is both costly and technically challenging. Here we developed a novel distributed fiber optic sensing technique that employs microwave modulation for phase measurement in signals returned from submarine repeaters. We transformed a trans‐Atlantic telecom cable into an 81‐sensor array and measured sub‐millihertz strains. The strains correlate with ocean tide height variations in phase, suggesting a dominant factor of the cable's Poisson's effect. Large strains observed at fiber spans located in the shallow water match the strong variations of simulated seafloor temperature. This study presents the first experimental confirmation of detecting sub‐millihertz signals using trans‐oceanic distributed sensing with submarine cables at span‐wise spatial resolution (∼80 km), opening the potential for cost‐efficient tsunami early warning and long‐term ocean temperature monitoring compatible with active data‐carrying fibers.more » « less
-
null (Ed.)Seafloor geophysical instrumentation is challenging to deploy and maintain but critical for studying submarine earthquakes and Earth’s interior. Emerging fiber-optic sensing technologies that can leverage submarine telecommunication cables present an opportunity to fill the data gap. We successfully sensed seismic and water waves over a 10,000-kilometer-long submarine cable connecting Los Angeles, California, and Valparaiso, Chile, by monitoring the polarization of regular optical telecommunication channels. We detected multiple moderate-to-large earthquakes along the cable in the 10-millihertz to 5-hertz band. We also recorded pressure signals from ocean swells in the primary microseism band, implying the potential for tsunami sensing. Our method, because it does not require specialized equipment, laser sources, or dedicated fibers, is highly scalable for converting global submarine cables into continuous real-time earthquake and tsunami observatories.more » « less
-
Designing power cables that provide high power and low system mass is one of the major goals in achieving the future all-electric wide-body aircraft. Radiative and convective heat transfers from a cable's surface to the surrounding air determine how much current is permitted to flow through it. At a cruising altitude of 12.2 km (18.8 kPa) for wide-body aircraft, the limited heat transfer by convection poses thermal issues for the design of aircraft cables. These thermal challenges are exacerbated for bipolar electric power systems (EPS), which are usually made up of two power lines next to each other. The cable's surface area affects both convective and radiative heat transfers. Changing the shape of the cable is one technique to improve heat transfers and compensate for the reduced convective heat transfer caused by low air pressure. In comparison to cylindrical and cuboid cables, the rectangular geometry design gives a bigger contact area with the surrounding atmosphere for the same cross-section area, hence it is anticipated that the heat transfer would rise and as a result, the cable's maximum power-carrying capability will be higher. The purpose of this paper is to design ±5 kV bipolar MVDC power cables with rectangular geometry to raise the maximum current carrying capacity of the cable and analyze its performance with bipolar cylindrical and cuboid geometries.more » « less
An official website of the United States government

