Title: Combined Additive and Laser-Induced Processing of Functional Structures for Monitoring under Deformation
This research introduces a readily available and non-chemical combinatorial production approach, known as the laser-induced writing process, to achieve laser-processed conductive graphene traces. The laser-induced graphene (LIG) structure and properties can be improved by adjusting the laser conditions and printing parameters. This method demonstrates the ability of laser-induced graphene (LIG) to overcome the electrothermal issues encountered in electronic devices. To additively process the PEI structures and the laser-induced surface, a high-precision laser nScrypt printer with different power, speed, and printing parameters was used. Raman spectroscopy and scanning electron microscopy analysis revealed similar results for laser-induced graphene morphology and structural chemistry. Significantly, the 3.2 W laser-induced graphene crystalline size (La; 159 nm) is higher than the higher power (4 W; 29 nm) formation due to the surface temperature and oxidation. Under four-point probe electrical property measurements, at a laser power of 3.8 W, the resistivity of the co-processed structure was three orders of magnitude larger. The LIG structure and property improvement are possible by varying the laser conditions and the printing parameters. The lowest gauge factor (GF) found was 17 at 0.5% strain, and the highest GF found was 141.36 at 5%.  more » « less
Award ID(s):
1735968
PAR ID:
10525160
Author(s) / Creator(s):
; ;
Publisher / Repository:
Polymers
Date Published:
Journal Name:
Polymers
Volume:
15
Issue:
2
ISSN:
2073-4360
Page Range / eLocation ID:
443
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. This study aimed to explore lignin as a naturally occurring aromatic precursor for the synthesis of LIG and further fabrication of ultrasensitive strain sensors for the detection of small deformations. One-step direct laser writing (DLW) induced high quality porous graphene, so called laser induced graphene (LIG), from kraft lignin under the conditions optimized for laser power, focus distance, and lignin loading. An electrode based on the resulting LIG was facilely fabricated by transferring LIG onto an elastomeric substrate ( i.e. , Dragon Skin™). The novel LIG transfer was facilitated by spin coating followed by water lifting, leading to the full retention of porous graphene onto the elastomeric substrate. The strain sensor was shown to be highly sensitive to small human body motions and tiny deformations caused by vibrations. It had a working range of up to 14% strain with a gauge factor of 960 and showed high stability as evidenced by repetitive signals over 10 000 cycles at 4% strain. The sensor was also successfully demonstrated for detecting human speaking, breath, seismocardiography (SCG), and movement of pulse and eye. Overall, the lignin-derived LIG can serve as excellent piezoresistive materials for wearable, stretchable, and ultrasensitive strain sensors with applications in human body motion monitoring and sound-related applications. 
    more » « less
  2. null (Ed.)
    Structural health monitoring of fiber-reinforced composite materials is of critical importance due to their use in challenging structural applications where low density is required and the designs typically use a low factor of safety. In order to reduce the need for external sensors to monitor composite structures, recent attention has turned to multifunctional materials with integrated sensing capabilities. This work use laser induced graphene (LIG) to create multifunctional structure with embedded piezoresistivity for the simultaneous and in-situ monitoring of both strain and damage in fiberglass-reinforced composites. The LIG layers are integrated during the fabrication process through transfer printing to the surface of the prepreg before being laid up into the ply stack, and are thus located in the interlaminar region of the fiberglass-reinforced composite. The methods used in this work are simple and require no treatment or modification to the commercial fiberglass prepreg prior to LIG transfer printing which is promising for industrial scale use. The performance of the piezoresistive interlayer in monitoring both strain and damage in-situ are demonstrated via three-point bend and tensile testing. Additionally, the interlaminar properties of the fiberglass composites were observed to be largely maintained with the LIG present in the interlaminar region of the composite, while the damping properties were found to be improved. This work therefore introduces a novel multifunctional material with high damping and fully integrated sensing capabilities through a cost-effective and scalable process. 
    more » « less
  3. Structural health monitoring of fiber-reinforced composite materials is of critical importance due to their use in challenging structural applications where low density is required and the designs typically use a low factor of safety. In order to reduce the need for external sensors to monitor composite structures, recent attention has turned to multifunctional materials with integrated sensing capabilities. This work use laser induced graphene (LIG) to create multifunctional structure with embedded piezoresistivity for the simultaneous and in-situ monitoring of both strain and damage in fiberglass-reinforced composites. The LIG layers are integrated dur-ing the fabrication process through transfer printing to the surface of the prepreg before being laid up into the ply stack, and are thus located in the interlaminar region of the fiberglass-reinforced composite. The methods used in this work are simple and require no treatment or modification to the commercial fiberglass prepreg prior to LIG transfer printing which is promising for industrial scale use. The performance of the piezoresistive interlayer in monitoring both strain and damage in-situ are demonstrated via three-point bend and tensile testing. Addi-tionally, the interlaminar properties of the fiberglass composites were observed to be largely maintained with the LIG present in the interlaminar region of the composite, while the damping properties were found to be improved. This work therefore introduces a novel multifunctional material with high damping and fully inte-grated sensing capabilities through a cost-effective and scalable process. 
    more » « less
  4. Abstract The accurate, continuous analysis of healthcare-relevant gases such as nitrogen oxides (NO x ) in a humid environment remains elusive for low-cost, stretchable gas sensing devices. This study presents the design and demonstration of a moisture-resistant, stretchable NO x gas sensor based on laser-induced graphene (LIG). Sandwiched between a soft elastomeric substrate and a moisture-resistant semipermeable encapsulant, the LIG sensing and electrode layer is first optimized by tuning laser processing parameters such as power, image density, and defocus distance. The gas sensor, using a needlelike LIG prepared with optimal laser processing parameters, exhibits a large response of 4.18‰ ppm −1 to NO and 6.66‰ ppm −1 to NO 2 , an ultralow detection limit of 8.3 ppb to NO and 4.0 ppb to NO 2 , fast response/recovery, and excellent selectivity. The design of a stretchable serpentine structure in the LIG electrode and strain isolation from the stiff island allows the gas sensor to be stretched by 30%. Combined with a moisture-resistant property against a relative humidity of 90%, the reported gas sensor has further been demonstrated to monitor the personal local environment during different times of the day and analyze human breath samples to classify patients with respiratory diseases from healthy volunteers. Moisture-resistant, stretchable NO x gas sensors can expand the capability of wearable devices to detect biomarkers from humans and exposed environments for early disease diagnostics. 
    more » « less
  5. null (Ed.)
    The continuous monitoring of strain in fiber-reinforced composites while in service typically requires bonding a network of sensors to the surface of the composite structure. To eliminate such needs, and to reduce bulk and limit additional weight, this work utilizes the transfer printing of laser induced graphene (LIG) strain gauges onto the surface of commercial fiberglass prepreg for the in situ self-sensing of strain. The resultant embedded strain sensor is entirely integrated within the final composite material, therefore reducing weight and eliminating limitations due to external bonding compared to current alternatives. Additionally, the simple printing process used here allows for the customization of the size and sensing requirements for various applications. The LIG strain sensor is shown to be capable of tracking monotonic cyclic strain as shown during tensile loading and unloading of the host composite, while also proving capable of tracking the dynamic motion of the composite which is characterized via frequency response and sinusoidal base excitation. The LIG strain gauge in this work can thus be used for tracking either quasi-static or dynamic variations in strain for the determination of the deformation experienced by the material, as well as the frequency content of the material for structural health monitoring purposes. 
    more » « less