Title: Microfluidic Biosensor for the In Vitro Electrophysiological Characterization of Actin Bundles
The essential cytoskeletal protein actin and its func- tions are paramount for motility, communication, and locomotive processes in eukaryotic cells. Detection and quantification of actin protein is of great interest for in vitro studies potentially eluci- dating unknown cellular mechanisms affecting drug responses with an extension to the study of disease states (e.g., study of neurodegenerative disorders). To this end, development of biomedical platforms and biosensors plays an important role in providing reliable and sensitive devices to study such intracellular constructs. Here, we present for the first time the microfabrica- tion, characterization, testing, and electrical/interfacial modeling of a microfluidic biosensor for actin protein characterization. The device allows for the interaction and characterization of actin bundles using electrochemical impedance spectroscopy (EIS). The device was tested with 1 μM and 8 μM actin bundles concentrations producing shifts in impedance response in the significant biological frequency of 1 kHz from 17 to 30 kOhm (k). Interfacial capacitance and electrical modeling showed that at increasing actin bundles concentrations, the distance from the electrode to the diffusion region (Debye length) was reduced from 386 to 136, and from 1526 to 539 Å. Inter- facial capacitance was evaluated for 1 μM concentration at two dielectric constants (εr = 5 and 78) resulting in 3.8 and 15.6 mF/m2 respectively. Similarly, for 8 μM concentration, interfacial capacitance resulted in 10.1 and 43.3 mF/m2 for the same values of εr. Based on these theoretical calculations, the interface model could accurately predict the quantification of the actin bundles previously elucidated by the experimental EIS method.  more » « less
Award ID(s):
1943266
PAR ID:
10528069
Author(s) / Creator(s):
; ; ; ;
Publisher / Repository:
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS
Date Published:
Journal Name:
Journal of Microelectromechanical Systems
Volume:
33
Issue:
3
ISSN:
1057-7157
Page Range / eLocation ID:
350 to 361
Subject(s) / Keyword(s):
Actin, electrochemical impedance spectroscopy (EIS), interdigitated electrodes (IDE), interfacial capacitance, microfluidic biosensor, interface modeling
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Electrical Impedance Spectroscopy (EIS) has been widely used as a label-free and rapid characterization method for the analysis of cells in clinical research. However, the related work on exosomes (40–150 nm) and the particles of similar size has not yet been reported. In this study, we developed a new Lab-on-a-Chip (LOC) device to rapidly entrap a cluster of sub-micron particles, including polystyrene beads, liposomes, and small extracellular vesicles (exosomes), utilizing an insulator-based dielectrophoresis (iDEP) scheme followed by measuring their impedance utilizing an integrated electrical impedance sensor. This technique provides a label-free, fast, and non-invasive tool for the detection of bionanoparticles based on their unique dielectric properties. In the future, this device could potentially be applied to the characterization of pathogenic exosomes and viruses of similar size, and thus, be evolved as a powerful tool for early disease diagnosis and prognosis. 
    more » « less
  2. Khalil, Khalil Abdelrazek (Ed.)
    Electrical Impedance Spectroscopy (EIS) is a non-invasive and label-free technology that can characterize and discriminate cells based on their dielectric properties at a wide range of frequency. This characterization method has not been utilized for small extracellular vesicles (exosomes) with heterogenous and nano-scale size distribution. Here, we developed a novel label-free microelectronic impedance spectroscopy for non-invasive and rapid characterization of exosomes based on their unique dielectric properties. The device is comprised of an insulator-based dielectrophoretic (iDEP) module for exosomes isolation followed by an impedance spectroscopy utilizing the embedded micro-electrodes. This device is capable of distinguishing between exosomes harvested from different cellular origins as the result of their unique membrane and cytosolic compositions at a wide range of frequency. Therefore, it has the potential to be further evolved as a rapid tool for characterization of pathogenic exosomes in clinical settings. 
    more » « less
  3. Extracellular vesicles (EVs) have gained considerable attention as vital circulating biomarkers since their structure and composition resemble the originating cells. The investigation of EVs’ biochemical and biophysical properties is of great importance to map them to their parental cells and to better understand their functionalities. In this study, a novel frequency-dependent impedance measurement system has been developed to characterize EVs based on their unique dielectric properties. The system is composed of an insulator-based dielectrophoretic (iDEP) device to entrap and immobilize a cluster of vesicles followed by utilizing electrical impedance spectroscopy (EIS) to measure their impedance at a wide frequency spectrum, aiming to analyze both their membrane and cytosolic charge-dependent contents. The EIS was initially utilized to detect nano-size vesicles with different biochemical compositions, including liposomes synthesized with different lipid compositions, as well as EVs and lipoproteins with similar biophysical properties but dissimilar biochemical properties. Moreover, EVs derived from the same parental cells but treated with different culture conditions were characterized to investigate the correlation of impedance changes with biochemical properties and functionality in terms of pro-inflammatory responses. The system also showed the ability to discriminate between EVs derived from different cellular origins as well as among size-sorted EVs harbored from the same cellular origin. This proof-of-concept approach is the first step towards utilizing EIS as a label-free, non-invasive, and rapid sensor for detection and characterization of pathogenic EVs and other nanovesicles in the future. 
    more » « less
  4. Abstract Printable and wearable plant sensors offer an approach for collecting critical environmental data at high spatial resolution to understand plant conditions and aid land management practices. Here, screen printed capacitive devices that can measure relative humidity (RH) directly at the plant‐environment interface, are demonstrated in an ultra‐thin (<6 µm) form factor. Using screen printing and a temporary tattoo transfer process, a simple technique is established to: 1) enclose printed electronic features between two layers of ethyl cellulose (EtC), 2) mount printed microparticle carbon‐based electronics onto a variety of plant structures, and 3) dramatically increase the capacitance and sensitivity for humidity sensors when compared to unencapsulated devices. This sandwich tattoo capacitor (STC) platform exhibits an RH sensitivity up to 1000 pF/%RH and stability while mounted to living plant leaves over several days. Electrochemical impedance spectroscopy (EIS) validates the formation of electric double layers within the EtC films that encapsulate the printed electrodes providing tunable capacitance values based on the ionic concentration of the device transfer fluid. 
    more » « less
  5. In this work we investigate the electrical properties of phospholipid bilayer membranes (LBMs) formed from phosphatidylserine by analyzing two experimental setups. The Electrochemical Impedance Spectra (EIS) of phosphatidylserine show that a lipid bilayer membrane formed from this phospholipid has an average specific electrical resistance of 3.466 k Ω.cm 2 and an average capacitance of 0.385 µF/cm 2 . Some of the major factors that affect the LBM resistance include electroporation, the method of deposition, and the surface tension in microchannels for supported LBMs. Therefore, wide apertures remain the most accurate method for supporting LBMs. 
    more » « less