skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Reduced graphene oxide-modified electrodes via fused deposition modeling 3D printing for hydrogen peroxide sensor
Abstract Fused deposition modeling 3D printing provides a cost-effective and streamlined method for producing electrochemical sensors, overcoming the challenges associated with material selection, complex fabrication processes, and reproducibility issues. This study introduces an innovative approach utilizing a dual-printer setup to simplify the manufacturing of sensor electrodes. A critical enhancement in this process is the surface modification with reduced graphene oxide (rGO), which not only improves the electrochemical characteristics but also induces a wrinkled structure on the 3D printed surface. These wrinkles significantly increase the surface area, directly boosting the electrode’s electrochemical performance. Comprehensive characterization of the electrode surfaces, both before and after rGO modification, demonstrates a substantial increase in sensitivity, with a fortyfold improvement observed in hydrogen peroxide (H2O2) amperometric measurements. This breakthrough paves the way for advanced applications in 3D printed electrochemical sensors.  more » « less
Award ID(s):
1762792
PAR ID:
10559097
Author(s) / Creator(s):
; ; ; ; ;
Publisher / Repository:
IOPScience
Date Published:
Journal Name:
2D Materials
Volume:
11
Issue:
4
ISSN:
2053-1583
Page Range / eLocation ID:
045008
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract 3D continuous mesoscale architectures of nanomaterials possess the potential to revolutionize real‐time electrochemical biosensing through higher active site density and improved accessibility for cell proliferation. Herein, 3D microporous Ti3C2TXMXene biosensors are fabricated to monitor antibiotic release in tissue engineering scaffolds. The Ti3C2TX‐coated 3D electrodes are prepared by conformal MXene deposition on 3D‐printed polymer microlattices. The Ti3C2TXMXene coating facilitates direct electron transfer, leading to the efficient detection of common antibiotics such as gentamicin and vancomycin. The 3D microporous architecture exposes greater electrochemically active MXene surface area, resulting in remarkable sensitivity for detecting gentamicin (10–1 mM) and vancomycin (100–1 mM), 1000 times more sensitive than control electrodes composed of 2D planar films of Ti3C2TXMXene. To characterize the suitability of 3D microporous Ti3C2TXMXene sensors for monitoring drug elution in bone tissue regeneration applications, osteoblast‐like (MG‐63) cells are seeded on the 3D MXene microlattices for 3, 5, and 7 days. Cell proliferation on the 3D microporous MXene is tracked over 7 days, demonstrating its promising biocompatibility and its clinical translation potential. Thus, 3D microporous Ti3C2TXMXene can provide a platform for mediator‐free biosensing, enabling new applications for in vivo monitoring of drug elution. 
    more » « less
  2. Abstract Light addressable electrochemical (LAE) sensors have seen great utility in the past several years because they enable multiple localized electrochemical measurements to be performed on a single macroscopic electrode, opening up applications in imaging, biosensing, surface patterning, and multiplexing. In this study, we investigated the effects of electrodeposition on the formation of LAE sensors formed between n‐Si and electrodeposited Pt. We prepared sensors by electrodepositing Pt onto freshly‐etched n‐Si under a variety of conditions, varying the Pt precursor concentration, electrodeposition time, supporting electrolyte, and potential waveform. We characterized the sensors using a combination of atomic force microscopy, electrochemical impedance spectroscopy, and cyclic voltammetry. This study shows that the electrodeposition parameters have a dramatic impact on the morphology of the electrodeposited surfaces, sensor stability, and sensitivity towards H2O2. Specifically, we observed that continuous Pt films prepared with a higher Pt precursor concentration were more stable and had better linearity, higher sensitivity, and broader dynamic range than those prepared with a lower Pt precursor concentration. The stability and increased H2O2sensing performance correlate strongly with an increase in the Pt islands which make up the film. These data highlight that the morphology of the metal in semiconductor/metal junction LAE sensors has an impact on important performance metrics like stability and sensitivity. They also demonstrate the need for semiconductor/metal LAE sensors to be studied using micro‐ and nanoscale imaging techniques in order to more deeply understand their performance characteristics. 
    more » « less
  3. 3D-printed microdevices have become increasingly important to the advancement of point-of-care (POC) immunoassays. Despite its great potential, using 3D-printed surfaces on the solid support for immunorecognition has been limited due to the non-ideal adsorption properties for many photocurable resins. In this work, we report a simple surface modification protocol that works for diverse commercial photocurable resins, improving ELISAs performed directly on 3D-printed devices. This surface modification strategy involves surface activation via air plasma followed by the one-step incubation of GLYMO-labeled streptavidin. We successfully immobilized biotinylated anti-activin A antibodies on the 3D-printed surfaces and performed the complete ELISA protocol on the 3D-printed surfaces. We demonstrated that this protocol achieved an improved performance over passive adsorption for ELISAs. The present method is also compatible with diverse commercial resins and works with both microwells and microchannels. Finally, this method demonstrated a comparable limit of detection to the ELISA performed using commercial microwells. We believe the simplicity and broad compatibility of the present surface modification strategy will facilitate the development of 3D-printed POC ELISA devices. 
    more » « less
  4. In this paper, we report the development of tailored 3D-structured (engineered) polymer-metal interfaces to create enhanced ‘engineered ionic polymer metal composite’ (eIPMC) sensors towards soft, self-powered, high sensitivity strain sensor applications. We introduce a novel advanced additive manufacturing approach to tailor the morphology of the polymer-electrode interfaces via inkjet-printed polymer microscale features. We hypothesize that these features can promote inhomogeneous strain within the material upon the application of external pressure, responsible for improved compression sensing performance. We formalize a minimal physics-based chemoelectromechanical model to predict the linear sensor behavior of eIPMCs in both open-circuit and short-circuit sensing conditions. The model accounts for polymer-electrode interfacial topography to define the inhomogeneous mechanical response driving electrochemical transport in the eIPMC. Electrochemical experiments demonstrate improved electrochemical properties of the inkjet-printed eIPMCs as compared to the standard IPMC sensors fabricated from Nafion polymer sheets. Similarly, compression sensing results show a significant increase in sensing performance of inkjet-printed eIPMC. We also introduce two alternative methods of eIPMC fabrication for sub-millimeter features, namely filament-based fused-deposition manufacturing and stencil printing, and experimentally demonstrate their improved sensing performance. Our results demonstrate increasing voltage output associated to increasing applied mechanical pressure and enhanced performance of the proposed eIPMC sensors against traditional IPMC based compression sensors. 
    more » « less
  5. In this paper, we report the development of tailored 3D-structured (engineered) polymer-metal interfaces to create enhanced 'engineered ionic polymer metal composite' (eIPMC) sensors towards soft, self-powered, high sensitivity strain sensor applications. We introduce a novel advanced additive manufacturing approach to tailor the morphology of the polymer-electrode interfaces via inkjet-printed polymer microscale features. We hypothesize that these features can promote inhomogeneous strain within the material upon the application of external pressure, responsible for improved compression sensing performance. We formalize a minimal physics-based chemoelectromechanical model to predict the linear sensor behavior of eIPMCs in both open-circuit and short-circuit sensing conditions. The model accounts for polymer-electrode interfacial topography to define the inhomogeneous mechanical response driving electrochemical transport in the eIPMC. Electrochemical experiments demonstrate improved electrochemical properties of the inkjet-printed eIPMCs as compared to the standard IPMC sensors fabricated from Nafion polymer sheets. Similarly, compression sensing results show a significant increase in sensing performance of inkjet-printed eIPMC. We also introduce two alternative methods of eIPMC fabrication for sub-millimeter features, namely filament-based fused-deposition manufacturing and stencil printing, and experimentally demonstrate their improved sensing performance. Our results demonstrate increasing voltage output associated to increasing applied mechanical pressure and enhanced performance of the proposed eIPMC sensors against traditional IPMC based compression sensors. 
    more » « less