skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Zero-crosstalk silicon photonic refractive index sensor with subwavelength gratings
Abstract Silicon photonic index sensors have received significant attention for label-free bio and gas-sensing applications, offering cost-effective and scalable solutions. Here, we introduce an ultra-compact silicon photonic refractive index sensor that leverages zero-crosstalk singularity responses enabled by subwavelength gratings. The subwavelength gratings are precisely engineered to achieve an anisotropic perturbation-led zero-crosstalk, resulting in a single transmission dip singularity in the spectrum that is independent of device length. The sensor is optimized for the transverse magnetic mode operation, where the subwavelength gratings are arranged perpendicular to the propagation direction to support a leaky-like mode and maximize the evanescent field interaction with the analyte space. Experimental results demonstrate a high wavelength sensitivity of − 410 nm/RIU and an intensity sensitivity of 395 dB/RIU, with a compact device footprint of approximately 82.8 μm2. Distinct from other resonant and interferometric sensors, our approach provides an FSR-free single-dip spectral response on a small device footprint, overcoming common challenges faced by traditional sensors, such as signal/phase ambiguity, sensitivity fading, limited detection range, and the necessity for large device footprints. This makes our sensor ideal for simplified intensity interrogation. The proposed sensor holds promise for a range of on-chip refractive index sensing applications, from gas to biochemical detection, representing a significant step towards efficient and miniaturized photonic sensing solutions. Graphical Abstract  more » « less
Award ID(s):
2144568
PAR ID:
10560468
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
Springer
Date Published:
Journal Name:
Nano Convergence
Volume:
11
Issue:
1
ISSN:
2196-5404
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Miller, Benjamin L.; Weiss, Sharon M.; Danielli, Amos (Ed.)
    Evanescent field silicon photonics in a silicon-on-insulator or silicon-nitride-on-insulator platforms have been effectively utilized to demonstrate chemical and biosensors over the past decade with applications in the detection of nucleic acids and protein biomarkers for cancers, viruses and infectious diseases, and environmental toxins. By balancing the requirements for efficient low-loss transmission through the waveguide and enhancing light-matter interaction such as with molecules binding on the high index material surfaces in resonant microcavities, slow light and interferometer geometries, various high sensitivity biosensors have been experimentally demonstrated down to few femtograms/ml. various slotted microcavities and waveguides have been experimentally demonstrated. In recent years, subwavelength waveguides have demonstrated high bulk spectral sensitivities approaching ~500nm/RIU (RIU=refractive index unit) in periodic structures with lattice constant (Λ) <<(λ/2n eff ) where n eff is the effective index at wavelength λ. While most experimental demonstrations have been in subwavelength ring resonator geometries, in this research, in addition to experimental demonstration of bulk spectral sensitivity ~775nm/RIU in subwavelength waveguides in interferometer configurations, we investigate optimized geometries that can reach sensitivities ~70,000nm/RIU in compact dimensions. In contrast to Mach-Zehnder interferometer (MZI) sensors of the same geometric interferometer arm lengths, the reflected path in Michelson interferometers (MI) doubles the optical path length, and thus effectively doubles the phase shift in the presence of an analyte. The interference fringe linewidths are narrowed compared to the equivalent MZI and would thus enable smaller changes in analyte concentration to be discerned from the fringe spectra. 
    more » « less
  2. The rapid growth of point-of-care tests demands for biomolecule sensors with higher sensitivity and smaller size. We developed an optofluidic metasurface that combined silicon photonics and nanofluidics to achieve a lateral flow-through biosensor to fulfill the needs. The metasurface consists of a 2D array of silicon nanoposts fabricated on a silicon-on-insulator substrate. The device takes advantage of the high-Q resonant modes associated with the optical bound state and the nanofluidic delivery of analyte to overcome the problem of diffusion-limited detection that occurs in almost all conventional biosensors and offer a high refractive index sensitivity. We used rigorous coupled wave analysis and finite element analysis to design and optimize the device. We will present its photonic band diagram to identify the optical bound state and high-Q resonance modes near 1550 nm. The device was fabricated using e-beam lithography followed by a lift-off and reactive ion etching process. Reflectance of the sensor was measured using a tunable laser and a photodetector. The preliminary result shows a refractive index sensitivity of 720 nm/RIU. Furthermore, we implemented the optical metasurface as a lateral flow-through biosensor by covering the nanoposts using a PDMS cover. The nanofluidic channels are formed between the nanoposts for the flow of samples. The lateral flow-through sensor was used to detect the epidermal growth factor receptor (ErbB2), a widely used protein biomarker for breast cancer screening. The results show that the device can quantitatively measure the binding of ErBb2 antibody and ErBb2 by the continuous monitoring of the resonant wavelength shift. 
    more » « less
  3. Abstract Refractive index (RI) sensors are of great interest for label-free optical biosensing. A tapered optical fiber (TOF) RI sensor with micron-sized waist diameters can dramatically enhance sensor sensitivity by reducing the mode volume over a long distance. Here, a simple and fast method is used to fabricate highly sensitive refractive index sensors based on localized surface plasmon resonance (LSPR). Two TOFs ( l  = 5 mm) with waist diameters of 5 µm and 12 µm demonstrated sensitivity enhancement at λ = 1559 nm for glucose sensing (5–45 wt%) at room temperature. The optical power transmission decreased with increasing glucose concentration due to the interaction of the propagating light in the evanescent field with glucose molecules. The coating of the TOF with gold nanoparticles (AuNPs) as an active layer for glucose sensing generated LSPR through the interaction of the evanescent wave with AuNPs deposited at the tapered waist. The results indicated that the TOF (Ø = 5 µm) exhibited improved sensing performance with a sensitivity of 1265%/RIU compared to the TOF (Ø = 12 µm) at 560%/RIU towards glucose. The AuNPs were characterized using scanning electron microscopy and ultraviolent-visible spectroscopy. The AuNPs-decorated TOF (Ø = 12 µm) demonstrated a high sensitivity of 2032%/RIU toward glucose. The AuNPs-decorated TOF sensor showed a sensitivity enhancement of nearly 4 times over TOF (Ø = 12 µm) with RI ranging from 1.328 to 1.393. The fabricated TOF enabled ultrasensitive glucose detection with good stability and fast response that may lead to next-generation ultrasensitive biosensors for real-world applications, such as disease diagnosis. 
    more » « less
  4. null (Ed.)
    Microsphere Photolithography (MPL) is a nanopatterning technique that utilizes a self-assembled monolayer of microspheres as an optical element to focus incident radiation inside a layer of photoresist. The microspheres produces a sub-diffraction limited photonic-jet on the opposite side of each microsphere from the illumination. When combined with pattern transfer techniques such as etching/lift-off, MPL provides a versatile, low-cost fabrication method for producing hexagonal close-packed metasurfaces. This article investigates the MPL process for creating refractive index (RI) sensors on the cleaved tips of optical fiber. The resonant wavelength of metal elements on the surface is dependent on the local dielectric environment and allows the refractive index of an analyte to be resolved spectrally. A numerical study of hole arrays defined in metal films shows that the waveguide mode provides good sensitivity to the analyte refractive index. This can be readily tuned by adjusting the MPL exposure and the simulation results guide the fabrication of a defect tolerant refractive index sensor on the tip of a fiber tip with a sensitivity of 613 nm/RIU. The conformal nature of the microsphere monolayer simplifies the fabrication process and provides a viable alternative to direct-write techniques such as Focused Ion Beam (FIB) milling 
    more » « less
  5. To elucidate the secretary function of immune cells, we develop a nanoplasmonic circular interferometric biosensor based on intensity interrogation for label-free and dynamic sensing of molecular secretion. Exceptional sensitivity has been demonstrated through coupling free light and surface plasmon polariton (SPPs) waves, which generates a constructive and deconstructive interference pattern with high contrast and narrow linewidth when illuminated by white light. Alternatively, by adopting a narrow-band LED source and a CCD camera in this work, the transmission intensity of multiple sensing units is monitored simultaneously with a simple collinear optical setup. This intensity-modulated sensing platform yields a resolution of 4.1 × 10 −5 refractive index unit (RIU) with a high temporal resolution of 1 s and a miniaturized footprint as small as 9.8 × 9.8 μm 2 for a single sensing unit. By integrating the signals from multiple sensor units, the resolution of a 12 × 12 sensor array was found to reach 7.3 × 10 −6 RIU. We apply this sensor array to detect matrix metalloproteinase 9 (MMP-9) secretion from human monocytic cells, THP-1, at different time points after lipopolysaccharide (LPS) simulation and the results are in good agreement with enzyme-linked immunosorbent assay (ELISA) tests, but without the need for labeling. The spatial, temporal and mass resolutions of the sensor array are found to exceed other label-free technologies. These biomolecular arrays, incorporated in a microfluidic sensor platform, hold great potential for the study the dynamics and interplay of cell secretion signals and achieving a better understanding of single cell functions. 
    more » « less