skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Enhanced penetration depth in optical coherence tomography and photoacoustic microscopy in vivo enabled by absorbing dye molecules
The scattering and absorption of light within biological tissue severely limits the penetration depth of optical imaging techniques. Recently, it has been found that water-soluble, strongly absorbing dye molecules, such as tartrazine, can achievein vivotissue transparency by increasing the refractive index of aqueous components in tissue, as predicted by the Lorentz oscillator model and Kramers–Kronig relations. In this study, we topically applied absorbing dye molecules to the abdominal skin of pigmented and nonpigmented mice to enhance the penetration depth of optical coherence tomography (OCT) and photoacoustic microscopy (PAM). In both types of mice, the penetration depth of OCT was significantly improved using tartrazine and 4-aminoantipyrine. As predicted by the Kramers–Kronig relations and absorption spectra of the dyes, mice treated with 4-aminoantipyrine showed significantly improved penetration depth compared to mice treated with tartrazine for the PAM system with 532 nm excitation. These findings further demonstrate the use of absorbing dye molecules for achieving tissue transparency to enhance the penetration depth of depth-resolved optical imaging modalities in skin, thus accelerating the translation of these technologies in clinical areas, such as dermatology.  more » « less
Award ID(s):
2144788
PAR ID:
10565532
Author(s) / Creator(s):
; ; ; ; ; ; ;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Optica
Volume:
12
Issue:
1
ISSN:
2334-2536
Format(s):
Medium: X Size: Article No. 24
Size(s):
Article No. 24
Sponsoring Org:
National Science Foundation
More Like this
  1. For many clinical applications, such as dermatology, optical coherence tomography (OCT) suffers from limited penetration depth due primarily to the highly scattering nature of biological tissues. Here, we present a novel implementation of dual-axis optical coherence tomography (DA-OCT) that offers improved depth penetration in skin imaging at 1.3 µm compared to conventional OCT. Several unique aspects of DA-OCT are examined here, including the requirements for scattering properties to realize the improvement and the limited depth of focus (DOF) inherent to the technique. To overcome this limitation, our approach uses a tunable lens to coordinate focal plane selection with image acquisition to create an enhanced DOF for DA-OCT. This improvement in penetration depth is quantified experimentally against conventional on-axis OCT using tissue phantoms and mouse skin. The results presented here suggest the potential use of DA-OCT in situations where a high degree of scattering limits depth penetration in OCT imaging. 
    more » « less
  2. The anisotropic optical absorption edge of β-Ga2O3 follows a modified Beer–Lambert law having two effective absorption coefficients. The absorption coefficient of linearly polarized light reduces to the least absorbing direction beyond a critical penetration depth, which itself depends on polarization and wavelength. To understand this behavior, a Stokes vector analysis is performed to track the polarization state as a function of depth. The weakening of the absorption coefficient is associated with a gradual shift of linear polarization to the least absorbing crystallographic direction in the plane, which is along the a-exciton within the (010) plane or along the b-exciton in the (001) plane. We show that strong linear dichroism near the optical absorption edge causes this shift in β-Ga2O3, which arises from the anisotropy and spectral splitting of the physical absorbers, i.e., excitons. The linear polarization shift is accompanied by a variation in the ellipticity due to the birefringence of β-Ga2O3. Analysis of the phase relationship between the incoming electric field to that at a certain depth reveals the phase speed as an effective refractive index, which varies along different crystallographic directions. The critical penetration depth is shown to be correlated with the depth at which the ellipticity is maximal. Thus, the anisotropic Beer–Lambert law arises from the interplay of both the dichroic and birefringent properties of β-Ga2O3. 
    more » « less
  3. Abstract Small organic molecules absorbing and emitting in the shortwave infrared (SWIR, 1000–2000 nm) region are desirable for biological imaging applications due to low auto‐fluorescence, reduce photon scattering, and good tissue penetration depth of photons which allows forin vivoimaging with high resolution and sensitivity. Si‐substituted xanthene‐based fluorophores with indolizine donors have demonstrated some of the longest wavelengths of absorption and emission from organic dyes. This work seeks to compare an indolizine heterocyclic nitrogen with dimethyl aniline nitrogen donors on otherwise identical Si‐substituted xanthene fluorophoresviaoptical spectroscopy, computational chemistry and electrochemistry. Three donors are compared including an indolizine donor, a ubiquitous dimethyl aniline donor, and a vinyl dimethyl aniline group that keeps the number of π‐bonds consistent with indolizine. Significantly higher quantum yields and molar absorptivity are observed in these studies for a dimethylamine‐based donor relative to a simple indolizine donor absorbing and emitting at similar wavelengths (~1312 nm emission). Substantially longer wavelengths are obtainable by appending aniline‐based groups to the indolizine donor (~1700 nm) indicating longer wavelengths can be accessed with indolizine donors while stronger emitters can be accessed with anilines in place of indolizine. 
    more » « less
  4. Fluorescence and photoacoustic imaging techniques offer valuable insights into cell- and tissue-level processes. However, these optical imaging modalities are limited by scattering and absorption in tissue, resulting in the low-depth penetration of imaging. Contrast-enhanced imaging in the near-infrared window improves imaging penetration by taking advantage of reduced autofluorescence and scattering effects. Current contrast agents for fluorescence and photoacoustic imaging face several limitations from photostability and targeting specificity, highlighting the need for a novel imaging probe development. This review covers a broad range of near-infrared fluorescent and photoacoustic contrast agents, including organic dyes, polymers, and metallic nanostructures, focusing on their optical properties and applications in cellular and animal imaging. Similarly, we explore encapsulation and functionalization technologies toward building targeted, nanoscale imaging probes. Bioimaging applications such as angiography, tumor imaging, and the tracking of specific cell types are discussed. This review sheds light on recent advancements in fluorescent and photoacoustic nanoprobes in the near-infrared window. It serves as a valuable resource for researchers working in fields of biomedical imaging and nanotechnology, facilitating the development of innovative nanoprobes for improved diagnostic approaches in preclinical healthcare. 
    more » « less
  5. Abstract Epidural anesthesia helps manage pain during different surgeries. Nonetheless, the precise placement of the epidural needle remains a challenge. In this study, we developed a probe based on polarization‐sensitive optical coherence tomography (PS‐OCT) to enhance the epidural anesthesia needle placement. The probe was tested on six porcine spinal samples. The multimodal imaging guidance used the OCT intensity mode and three distinct PS‐OCT modes: (1) phase retardation, (2) optic axis, and (3) degree of polarization uniformity (DOPU). Each mode enabled the classification of different epidural tissues through distinct imaging characteristics. To further streamline the tissue recognition procedure, convolutional neural network (CNN) were used to autonomously identify the tissue types within the probe's field of view. ResNet50 models were developed for all four imaging modes. DOPU imaging was found to provide the highest cross‐testing accuracy of 91.53%. These results showed the improved precision by PS‐OCT in guiding epidural anesthesia needle placement. 
    more » « less