Attention:The NSF Public Access Repository (PAR) system and access will be unavailable from 5:00 PM ET until 8:00 PM ET on Friday, September 11 due to maintenance. We apologize for the inconvenience.


Title: Tuning Fork Scanning Electrochemical Cell Microscopy for Resolving Morphological and Redox Properties of Single Ag Nanowires
We report a Tuning Fork Scanning Electrochemical Cell Microscopy (TF-SECCM) technique for providing morphological and electrochemical information of single redox-active entities. This new operation configuration of SECCM utilizes an electrolyte-filled nanopipette tip mounted onto a tuning fork force sensor to obtain a precise tip-sample distance control and surface morphological mapping. Redox activities of regions of interest can be investigated by scanning electrode potential by moving the nanopipette to any target regions while maintaining the constant force engagement of the tip with the sample. Using silver nanowires (Ag NWs) as a model system due to their extensive utilization in energy and sensing devices, TF-SECCM provides not only the topography of single Ag NWs but also their distinctive redox activities and catalytic hydrogen evolution reaction (HER) activities and electrolyte anion adsorption/desorption features in contrast to NW bundles and supporting substrate (e.g., indium tin oxide).  more » « less
Award ID(s):
2113505
PAR ID:
10569482
Author(s) / Creator(s):
;
Publisher / Repository:
ACS
Date Published:
Journal Name:
The Journal of Physical Chemistry Letters
Volume:
16
Issue:
3
ISSN:
1948-7185
Page Range / eLocation ID:
818 to 825
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Not AvailableScanning electrochemical cell microscopy (SECCM) produces nanoscale-resolution electrochemical maps of electrode surfaces using the meniscus at the tip of an electrolyte-filled nanopipette as a mobile electrochemical cell. While the use and range of applications of SECCM have grown rapidly since its introduction, the pathway to performing SECCM measurements can be daunting to those without direct access to expert users. This work fills this expertise gap by providing a step-by-step guide to performing one’s first SECCM experiments, including troubleshooting strategies, videos/images, suggested parameters and experimental systems, and representative data (of both successful experiments and common problems). No background in SECCM is assumed and fundamentals are clearly explained at each stage with a rationale for the experimental steps provided. This work provides an entry point for the uninitiated to understand and use this powerful nanoscale electrochemical characterization technique. 
    more » « less
  2. Well-ordered nanoparticle arrays are attractive platforms for a variety of analytical applications, but the fabrication of such arrays is generally challenging. Here, it is demonstrated that scanning electrochemical cell microscopy (SECCM) can be used as a powerful, instantly reconfigurable tool for the fabrication of ordered nanoparticle arrays. Using SECCM, Ag nanoparticle arrays were straightforwardly fabricated via electrodeposition at the interface between a substrate electrode and an electrolyte-filled pipet. By dynamically monitoring the currents flowing in an SECCM cell, individual nucleation and growth events could be detected and controlled to yield individual nanoparticles of controlled size. Characterization of the resulting arrays demonstrate that this SECCM-based approach enables spatial control of nanoparticle location comparable with the terminal diameter of the pipet employed and straightforward control over the volume of material deposited at each site within an array. These results provide further evidence for the utility of probe-based electrochemical techniques such as SECCM as tools for surface modification in addition to analysis. 
    more » « less
  3. We present scanning electrochemical cell microscopy (SECCM) studies of Ag nucleation and growth on carbon and indium tin oxide (ITO) electrodes. 
    more » « less
  4. {"Abstract":["Scanning electrochemical cell microscopy (SECCM) produces\n nanoscale-resolution electrochemical maps of electrode surfaces using the\n meniscus at the tip of an electrolyte-filled nanopipette as a mobile\n electrochemical cell. While the use and range of applications of SECCM\n have grown rapidly since its introduction, the pathway to performing SECCM\n measurements can be challenging for those without direct access to expert\n users. This work fills this gap by providing a step-by-step guide to\n performing SECCM experiments, including troubleshooting strategies,\n videos/images, suggested parameters and experimental systems, and\n representative data (of both successful experiments and common problems).\n This work provides an entry point for the uninitiated to make use of this\n powerful nanoscale electrochemical characterization technique."],"TechnicalInfo":["# Data from: A tutorial for scanning electrochemical cell microscopy\n (SECCM) measurements: Step-by-Step instructions, visual resources, and\n guidance for first experiments Dataset DOI:\n [10.5061/dryad.3j9kd51v4](10.5061/dryad.3j9kd51v4) ## Description of the\n data and file structure This file contains the data presented in "A\n Tutorial for Scanning Electrochemical Cell Microscopy (SECCM)\n Measurements: Step-by-Step Instructions, Visual Resources, and Guidance\n for First Experiments". ### Files and variables #### File:\n Capacitive\\_current\\_vs\\_scan\\_rate\\_FigS5.txt **Description:** Data for\n Figure S5 Capacitive current vs scan rate ##### Variables * Scan rate\n (V/s): * Capacitive Current (pA): #### File: Clean\\_Detachment\\_Fig17.txt\n **Description: Data for Fig 17 clean detachment**  ##### Variables * z\n (micrometers) * Current (pA) #### File: CV\\_Fig\\_2iA.txt\n **Description:** CV data for Figure 2iA ##### Variables * Potential (mV) *\n Current (pA) #### File: CV\\_Fig\\_2iB.txt **Description:** CV data for\n Figure 2iB ##### Variables * Potential (mV) * Current (pA) #### File:\n CV\\_Fig\\_2iC.txt **Description:** CV data for Figure 2iC ##### Variables *\n Potential (mV) * Current (pA) #### File: CV\\_Fig\\_16A.txt\n **Description:** CV data for Figure 16A ##### Variables * Potential (mV) *\n Current (pA) #### File: CV\\_Fig156.txt **Description:** CV data for Figure\n 16B ##### Variables * Potential (mV) * Current (pA) #### File:\n Electrical\\_Characterization\\_CV\\_Fig12.txt **Description:** CV data for\n Figure 12 ##### Variables * Potential (V) * Current (nA) #### File:\n Electrical\\_Characterization\\_i\\_t\\_Fig11.txt **Description:** Current vs\n time data for figure 11 ##### Variables * Time (s) * Current (nA) ####\n File: OC\\_1Vpers\\_CV\\_Fig5B.txt **Description:** Open circuit 1 V/s CV\n data for figure 5B ##### Variables * Potential (mV) * Current (pA) ####\n File: OC\\_5Vpers\\_CV\\_Fig5B.txt **Description:** Open circuit 5 V/s CV\n data for figure 5B ##### Variables * Potential (mV) * Current (pA) ####\n File: OC\\_Fig\\_5A\\_NoisyOffset.txt **Description:** Open circuit Current\n vs time data for Noisy and offset data in Figure 5A ##### Variables * Time\n (s) * Current (pA) #### File: OC\\_10Vpers\\_CV\\_FigS5.txt\n **Description:** Open circuit 10 V/s CV data for figure S5 ##### Variables\n * Potential (mV) * Current (pA) #### File: OC\\_FigS4\\_DDPCA\n **Description:** Open circuit data DDPCA amplifier Figure S4 #####\n Variables * Potential (V) * Current (pA) #### File: OC\\_Fig5A\\_Desired.txt\n **Description:** Open circuit Current vs time data for desired data in\n Figure 5A ##### Variables * Time (s) * Current (pA) #### File:\n Extended\\_Adhesion\\_Fig17.txt **Description:** Extended adhesion data in\n Figure 17 ##### Variables * Z (micrometers): * Current (nA) #### File:\n OC\\_0.1Vpers\\_CV\\_Fig5B.txt **Description:** Open circuit 0.1 V/s CV data\n for figure 5B ##### Variables * Potential (mV) * Current (pA) #### File:\n SECCM\\_imap\\_Fig2ii.txt **Description:** SECCM Current Map Data Figure 2ii\n ##### Variables * x coordinate (micrometers) * y coordinate (micrometers)\n * Current (pA) #### File: OC\\_FigS4\\_DLPCA **Description:** Open circuit\n data DLPCA amplifier Figure S4 ##### Variables * Potential (V) * Current\n (pA) #### File: SECCM\\_imap\\_Fig16.txt **Description:** SECCM Current map\n data Figure 16 ##### Variables * X (micrometers) * Y (micrometers) *\n Current (pA) #### File: SECCM\\_Z\\_height\\_map\\_FigS15.txt\n **Description:** SECCM topography map data Figure S15 ##### Variables * X\n (micrometers) * Y (micrometers) * Z (micrometers) #### File:\n Resistor\\_Fig6\\_Flatline.tsv **Description:** Flatline response data\n Figure 6 ##### Variables  * Potential (V) * Current (nA) #### File:\n Undesirable\\_CV\\_FigS13B.txt **Description:** Undesirable CV data Figure\n S13B ##### Variables * Potential (mV) * Current (nA) #### File:\n Undesirable\\_CV\\_FigS13A.txt **Description:** Undesirable CV Figure S13A\n ##### Variables * Potential (mV) * Current (nA) #### File:\n SECCM\\_z\\_height\\_map\\_Fig2iii.txt **Description:** SECCM topography map\n data Figure 2iii ##### Variables * x coordinate (micrometers) * y\n coordinate (micrometers) * z height (micrometers) #### File:\n Resistor\\_Fig6\\_Offset.txt **Description:** Offset response data Figure 6\n ##### Variables * Potential (V) * Current (nA) #### File:\n Resistor\\_Fig6\\_Desired.tsv **Description:** Desired resistor response\n data Figure 6 ##### Variables: * Potential (V) * Current (nA) #### File:\n Resistor\\_Fig6\\_Lim\\_current\\_range.tsv **Description:** Limited current\n range data Figure 6 ##### Variables * Potential (V) * Current (nA)"]} 
    more » « less
  5. Bimetallic nanoparticles often show properties superior to their single-component counterparts. However, the large parameter space, including size, structure, composition, and spatial arrangement, impedes the discovery of the best nanoparticles for a given application. High-throughput methods that can control the composition and spatial arrangement of the nanoparticles are desirable for accelerated materials discovery. Herein, we report a methodology for synthesizing bimetallic alloy nanoparticle arrays with precise control over their composition and spatial arrangement. A dual-channel nanopipet is used, and nanofluidic control in the nanopipet further enables precise tuning of the electrodeposition rate of each element, which determines the final composition of the nanoparticle. The composition control is validated by finite element simulation as well as electrochemical and elemental analyses. The scope of the particles demonstrated includes Cu–Ag, Cu–Pt, Au–Pt, Cu–Pb, and Co–Ni. We further demonstrate surface patterning using Cu–Ag alloys with precise control of the location and composition of each pixel. Additionally, combining the nanoparticle alloy synthesis method with scanning electrochemical cell microscopy (SECCM) allows for fast screening of electrocatalysts. The method is generally applicable for synthesizing metal nanoparticles that can be electrodeposited, which is important toward developing automated synthesis and screening systems for accelerated material discovery in electrocatalysis. 
    more » « less