skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Geometric analysis of airway trees shows that lung anatomy evolved to enable explosive ventilation and prevent barotrauma in cetaceans
Two new biomechanical challenges faced cetacean lungs compared to their terrestrial ancestors. First, hydrostatic pressures encountered during deep dives are sufficient to cause nearly full lung collapse, risking substantial barotrauma during surfacing if air is trapped in the fragile smaller airways. Second, rapid ventilation in large cetaceans requires correspondingly high ventilatory flow rates. In order to investigate how airway geometry evolved in response to these challenges, we characterized airway geometry from 12 species of cetaceans that vary in common dive depth and ventilatory behavior and a domestic pig using computed tomography. After segmenting the major airways, we generated centerline networks models for the larger airways and computed geometric parameters for each tree including mean branching angle, percent volume fraction, and Strahler branching, diameter, and length ratios. When airway geometry was regressed against ventilatory and diving parameters with phylogenetic least squares, neither average branching angle, percent volume fraction, Strahler length ratio or Strahler branching ratio significantly varied with common ventilatory mode or common diving depth. Higher Strahler diameter ratios were associated with slower ventilation and deeper diving depth, suggesting that cetacean lungs have responded to biomechanical pressures primarily with changes in airway diameter. High Strahler diameter ratios lungs in deeper diving species may help to facilitate more complete collapse of the delicate terminal airways by providing for a greater incompressible volume for air storage at depth. On the other hand, lungs with low Strahler diameter ratios would be better for fast ventilation because the gradual decrease in diameter moving distally should keep peripheral flow resistance low, maximizing ventilatory flow rates.  more » « less
Award ID(s):
2010666
PAR ID:
10570533
Author(s) / Creator(s):
; ; ; ;
Publisher / Repository:
bioRxiv
Date Published:
Format(s):
Medium: X
Institution:
bioRxiv
Sponsoring Org:
National Science Foundation
More Like this
  1. We investigate the influence of bifurcation geometry, asymmetry of daughter airways, surfactant distribution, and physicochemical properties on the uniformity of airway recruitment of asymmetric bifurcating airways. To do so, we developed microfluidic idealized in vitro models of bifurcating airways, through which we can independently evaluate the impact of carina location and daughter airway width and length. We explore the uniformity of recruitment and its relationship to the dynamic surface tension of the lining fluid and relate this behavior to the hydraulic (P Hyd ) and capillary (P Cap ) pressure drops. These studies demonstrate the extraordinary importance of P Cap in stabilizing reopening, even in highly asymmetric systems. The dynamic surface tension of pulmonary surfactant is integral to this stability because it modulates P Cap in a velocity-dependent manner. Furthermore, the surfactant distribution at the propagating interface can have a very large influence on recruitment stability by focusing surfactant preferentially to specific daughter airways. This implies that modification of the surfactant distribution through novel modes of ventilation could be useful in inducing uniformly recruited lungs, aiding in gas exchange, and reducing ventilator-induced lung injury. NEW & NOTEWORTHY The dynamic surface tension of pulmonary surfactant is integral to the uniformity of asymmetric bifurcation airway recruitments because it modulates capillary pressure drop in a velocity-dependent manner. Also, the surfactant distribution at the propagating interface can have a very large influence on recruitment stability by focusing surfactant preferentially to specific daughter airways. This implies that modification of the surfactant distribution through novel modes of ventilation could be useful in inducing uniformly recruited lungs, reducing ventilator-induced lung injury. 
    more » « less
  2. Neonatal respiratory distress syndrome is a potentially life-threatening condition that is often treated with the delivery of exogenous surfactants through a process called surfactant replacement therapy. This therapy includes the administration of the liquid surfactant through an endotracheal tube and mechanical ventilation. Due to the difficulty of imaging neonate lungs during this therapy, the success of surfactant delivery is often determined by observational techniques and evaluation of blood oxygen levels. The limitation of imaging creates challenges in evaluating the distribution of surfactant in airways. To address this limitation, we designed a computational, eight-generation, asymmetric neonate lung model using morphometric data to mimic the geometric structure of the human airway tree and fabricated it using an additive manufacturing technique. We used our model to study two-aliquot delivery of a clinically rated liquid surfactant under two different orientations to evaluate its distribution in airways. Our study offers a complex lung airway tree design that mimics the native geometry of the human airway tree to enable studies of therapeutics transport in airways. 
    more » « less
  3. The mechanics of ventilation in elasmobranchs have been described as a two-pump system which is dependent on the generation of differential pressures between the orobranchial and parabranchial cavities. However, this general model does not take into account sources of variation in parabranchial form and function. For example, the relative pressures that drive flow in each parabranchial chamber during ventilation remain largely unexplored. To address this gap, parabranchial pressures were collected from the Pacific spiny dogfish (Squalus suckleyi, n = 12) during routine ventilation using transducers inserted into parabranchial chambers 2, 3, and 5, numbered anteriorly to posteriorly. Pressure amplitudes collected from the three chambers displayed an attenuation of pressure amplitudes posteriorly, as well as differential, modular use of parabranchial chamber five. These observations have implications for the functioning of the ventilatory pump and indicate distinct ventilatory modes, leading us to propose a new model to describe ventilation in Squalus suckleyi. 
    more » « less
  4. Modeling aerosol dynamics in the airways is challenging, and most modern personalized in vitro tools consider only a single inhalation maneuver through less than 10% of the total lung volume. Here, we present an in vitro modeling pipeline to produce a device that preserves patient-specific upper airways while approximating deeper airways, capable of achieving total lung volumes over 7 liters. The modular system, called TIDAL, includes tunable inhalation and exhalation breathing capabilities with resting flow rates up to 30 liters per minute. We show that the TIDAL system is easily coupled with industrially and clinically relevant devices for aerosol therapeutics. Using a vibrating mesh nebulizer, we report central-to-peripheral (C:P) aerosol deposition measurements aligned with both in vivo and in silico benchmarks. These findings underscore the effectiveness of the TIDAL model in predicting airway deposition dynamics for inhalable therapeutics. 
    more » « less
  5. null (Ed.)
    ABSTRACT Anthropogenic noise can alter marine mammal behaviour and physiology, but little is known about cetacean cardiovascular responses to exposures, despite evidence that acoustic stressors, such as naval sonars, may lead to decompression sickness. Here, we measured heart rate and movements of two trained harbour porpoises during controlled exposure to 6–9 kHz sonar-like sweeps and 40 kHz peak-frequency noise pulses, designed to evoke acoustic startle responses. The porpoises initially responded to the sonar sweep with intensified bradycardia despite unaltered behaviour/movement, but habituated rapidly to the stimuli. In contrast, 40 kHz noise pulses consistently evoked rapid muscle flinches (indicative of startles), but no behavioural or heart rate changes. We conclude that the autonomous startle response appears decoupled from, or overridden by, cardiac regulation in diving porpoises, whereas certain novel stimuli may motivate oxygen-conserving cardiovascular measures. Such responses to sound exposure may contribute to gas mismanagement for deeper-diving cetaceans. 
    more » « less