skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


This content will become publicly available on January 4, 2026

Title: Assessing the Integrity of N95 Mask Elastomer Straps With Decontamination and Reuse
The rapid progression of the COVID‐19 pandemic revealed an inability to meet increased demand for N95 respirators. These respirators are designed to be used once and disposed, but throughout the pandemic, there was a need for their decontamination and reuse. This research investigates the effect of various decontamination methods on the chemical and mechanical properties of N95 mask straps made of natural rubber to explore how these straps change after decontamination and what materials characterization techniques are well‐suited to evaluate these changes. Using results from ozone decontamination, tensile testing of mask strap assemblies is identified as the most reliable way to quantify changes in strap properties with decontamination and reuse when compared to other analytical techniques. Additionally, visible strap degradation often precedes both strap failure and material property changes and can be a reasonable indicator to discontinue use. Aside from ozone, decontamination with other methods such as heat and UV light appears to be less damaging to the tested materials. Beyond the specific results presented, this study provides insight on testing strategies that can be employed to move forward with evaluating new materials and decontamination methods for use in future pandemics or in more resource‐limited regions.  more » « less
Award ID(s):
2031545
PAR ID:
10570660
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
Wiley Periodicals LLC.
Date Published:
Journal Name:
Journal of Applied Polymer Science
ISSN:
0021-8995
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    The US CDC has recognized moist-heat as one of the most effective and accessible methods of decontaminating N95 masks for reuse in response to the persistent N95 mask shortages caused by the COVID-19 pandemic. However, it is challenging to reliably deploy this technique in healthcare settings due to a lack of smart technologies capable of ensuring proper decontamination conditions of hundreds of masks simultaneously. To tackle these challenges, we developed an open-source wireless sensor platform---VeriMask1 ---that facilitates per-mask verification of the moist-heat decontamination process. VeriMask is capable of monitoring hundreds of masks simultaneously in commercially available heating systems and provides a novel throughput-maximization functionality to help operators optimize the decontamination settings. We evaluate VeriMask in laboratory and real-scenario clinical settings and find that it effectively detects decontamination failures and operator errors in multiple settings and increases the mask decontamination throughput. Our easy-to-use, low-power, low-cost, scalable platform integrates with existing hospital protocols and equipment, and can be broadly deployed in under-resourced facilities to protect front-line healthcare workers by lowering their risk of infection from reused N95 masks. We also memorialize the design challenges, guidelines, and lessons learned from developing and deploying VeriMask during the COVID-19 Pandemic. Our hope is that by reflecting and reporting on this design experience, technologists and front-line health workers will be better prepared to collaborate for future pandemics, regarding mask decontamination, but also other forms of crisis tech. 
    more » « less
  2. Abstract Filtering facepiece respirators (FFRs) provide effective protection against diseases spread through airborne infectious droplets and particles. The widespread use of FFRs during the COVID-19 pandemic has not only led to supply shortages, but the disposal of single-use facemasks also threatens the environment with a new kind of plastic pollution. While limited reuse of filtering facepiece respirators has been permitted as a crisis capacity strategy, there are currently no standard test methods available for decontamination before their repeated use. The decontamination of respirators can compromise the structural and functional integrity by reducing the filtration efficiency and breathability. Digital segmentation of X-ray microcomputed tomography (microCT) scans of the meltblown nonwoven layers of a specific N95 respirator model (Venus-4400) after treatment with one and five cycles of liquid hydrogen peroxide, ultraviolet radiation, moist heat, and aqueous soap solution enabled us to perform filtration simulations of decontaminated respirators. The computed filtration efficiencies for 0.3 µm particles agreed well with experimental measurements, and the distribution of particle penetration depths was correlated with the structural changes resulting from decontamination. The combination of X-ray microCT imaging with numerical simulations thus provides a strategy for quantitative evaluation of the effectiveness of decontamination treatments for a specific respirator model. 
    more » « less
  3. null (Ed.)
    Abstract Decontamination of N95 respirators is being used by clinicians in the face of a global shortage of these devices. Some treatments for decontamination, such as some vaporized hydrogen peroxide methods or ultraviolet methods, had no impact on respiratory performance, while other treatments resulted in substantial damage to masks. 
    more » « less
  4. The pandemic of SARS-CoV-2/COVID-19 was reported in December 2019 in Wuhan, China. Pertaining to its high transmissibility and wide host adaptability, this unique human coronavirus spread across the planet inflicting 115 million people and causing 2.5 million deaths (as of March 3rd, 2021). Limited or negligible pre-existing immunity to multiple SARS-CoV-2 variants has resulted in severe morbidity and mortality worldwide, as well as a record-breaking surge in the use of medical-surgical supplies and personal protective equipment. In response to the global need for effective sterilization techniques, this study evaluated the virucidal efficacy of FATHHOME’s self-contained, ozone-based dry-sanitizing device, by dose and time response assessment. We tested inactivation of human coronavirus, HCoV-OC43, a close genetic model of SARS-CoV-2, on porous (N95 filtering facepiece respirator/FFR) and nonporous (glass) surfaces. We started our assays with 20 ppm-10 min ozone exposure, and effectively reduced 99.8% and 99.9% of virus from glass and N95 FFR surfaces, respectively. Importantly, the virus was completely inactivated, below the detection limit (over 6-log10 reduction) with 25 ppm-15 min ozone exposure on both tested surfaces. As expected, a higher ozone exposure (50 ppm-10 min) resulted in faster inactivation of HCoV-OC43 with 100% inactivation from both the surfaces, with no residual ozone present after completion of the 5-min post exposure recapture cycle and no measurable increase in ambient ozone levels. These results confirmed that FATHHOME’s device is suitable for rapid decontamination of SARS-CoV-2-from worn items, frequently touched items, and PPE including N95 FFRs, face shields, and other personal items. 
    more » « less
  5. With the recent emergence of highly transmissible variants of the novel coronavirus SARS-CoV-2, the demand for N95 respirators is expected to remain high. The extensive use of N95 respirators by the public is susceptible to demand‐supply gaps and raises concern about their disposal, threatening the environment with a new kind of plastic pollution. Herein, we investigated the filtration performance of the N95 respirator by specifically analyzing the structure in the key filtration layers of meltblown nonwoven after decontamination with one and five cycles of liquid hydrogen peroxide, ultraviolet radiation, moist heat, and aqueous soap solution treatments. With the aid of X-ray microcomputed tomography (microCT) analysis, the local structural heterogeneity of the meltblown nonwoven has been unfolded and subsequently correlated with their filtration performance at a face velocity that matched with speaking conditions (∼3.89 m/s). The filtration efficiency results of the N95 respirator remain unaltered after performing one cycle of treatment modalities (except autoclave). 
    more » « less