Metasurfaces have been studied and widely applied to optical systems. A metasurface-based flat lens (metalens) holds promise in wave-front engineering for multiple applications. The metalens has become a breakthrough technology for miniaturized optical system development, due to its outstanding characteristics, such as ultrathinness and cost-effectiveness. Compared to conventional macro- or meso-scale optics manufacturing methods, the micro-machining process for metalenses is relatively straightforward and more suitable for mass production. Due to their remarkable abilities and superior optical performance, metalenses in refractive or diffractive mode could potentially replace traditional optics. In this review, we give a brief overview of the most recent studies on metalenses and their applications with a specific focus on miniaturized optical imaging and sensing systems. We discuss approaches for overcoming technical challenges in the bio-optics field, including a large field of view (FOV), chromatic aberration, and high-resolution imaging.
more »
« less
Inverse-designed large field-of-view polychromatic metalens for tri-color scanning fiber endoscopy
Abstract Metalenses, with their ultrathin thicknesses and their ease for achieving ultra small diameters, offer a promising alternative to refractive lenses in miniaturized imaging systems, such as endoscopes, potentially enabling applications in tightly confined spaces. However, traditional metalenses suffer from strong chromatic aberrations, limiting their utility in multi-color imaging. To address this limitation, here we present an inverse-designed polychromatic metalens with a diameter of 680 μm, focal length of 400 μm, and low dispersion across 3 distinct wavelengths at 643 nm, 532 nm, and 444 nm. The metalens collimates and steers light emitted from a scanning fiber tip, generating scanning beams across a 70° field-of-view to provide illumination for a scan-based imaging. The metalens provides a close-to-diffraction-limited 0.5° angular resolution, only restricted by the effective aperture of the system. The average relative efficiency among three design wavelengths is around 32% for on-axis angle and 13% averaged across the entire field-of-view. This work holds promise for the application of metalenses in endoscopes and other miniaturized imaging systems.
more »
« less
- Award ID(s):
- 2025489
- PAR ID:
- 10578188
- Publisher / Repository:
- Nature Publishing Group
- Date Published:
- Journal Name:
- Communications Engineering
- Volume:
- 4
- Issue:
- 1
- ISSN:
- 2731-3395
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Miniature handheld imaging devices and endoscopes based on coherent Raman scattering are promising for label-free in vivo optical diagnosis. Toward the development of these small-scale systems, a challenge arises from the design and fabrication of achromatic and high-end miniature optical components for both pump and Stokes laser wavelengths. Here, we report a metasurface converting a low-cost plano–convex lens into a water-immersion, nearly diffraction-limited and achromatic lens. The metasurface comprising amorphous silicon nanopillars is designed in a way that all incident rays arrive at the focus with the same phase and group delay, leading to corrections of monochromatic and chromatic aberrations of the refractive lens, respectively. Compared to the case without the metasurface, the hybrid metasurface-refractive lens has higher Strehl ratios than the plano–convex lens and a tighter depth of focus. The hybrid metasurface-refractive lens is utilized in spectroscopic stimulated Raman scattering and coherent anti-Stokes Raman scattering imaging for the differentiation of two different polymer microbeads. Subsequently, the hybrid metalens is harnessed for volumetric coherent Raman scattering imaging of bead and tissue samples. Finally, we discuss possible approaches to integrate such hybrid metalens in a miniature scanning system for label-free coherent Raman scattering endoscopes.more » « less
-
Theoretical bounds are commonly used to assess the limitations of photonic design. Here we introduce a more active way to use theoretical bounds, integrating them into part of the design process and identifying optimal system parameters that maximize the efficiency limit itself. As an example, we consider wide-field-of-view high-numerical-aperture metalenses, which can be used for high-resolution imaging in microscopy and endoscopy, but no existing design has achieved a high efficiency. By choosing aperture sizes to maximize an efficiency bound, setting the thickness according to a thickness bound, and then performing inverse design, we come up with high-numerical-aperture (NA=0.9) metalens designs with, to our knowledge, record-high 98% transmission efficiency and 92% Strehl ratio across all incident angles within a 60° field of view, reaching the maximized bound. This maximizing-efficiency-limit approach applies to any multi-channel system and can help a wide range of optical devices reach their highest possible performance.more » « less
-
We report a novel ultra-thin metalens design based on photonic crystal slab (PCS) resonance modes. We experimentally verified with a metalens structure based on amorphous silicon on a quartz material platform by implementing the optical guided resonance on the PCS. The PCS metalens designs feature an ultra-thin device layer of about 160 nm at an operation wavelength of 940 nm. A full 2π transmission phase transition is realized by varying the air hole sizes at the design wavelength. Metalens devices with different phase change gradients were designed and fabricated to achieve different NAs. A maximum of 86.4% focusing efficiency is achieved. Imaging capabilities are characterized, and clear images are observed within the field of view. The PC resonance-based phase modulation design can be applied to optical beam manipulation, phase plate design, imaging, and laser beam formation applications.more » « less
-
Head-mounted miniaturized two-photon microscopes are powerful tools to record neural activity with cellular resolution deep in the mouse brain during unrestrained, free-moving behavior. Two-photon microscopy, however, is traditionally limited in imaging frame rate due to the necessity of raster scanning the laser excitation spot over a large field-of-view (FOV). Here, we present two multiplexed miniature two-photon microscopes (M-MINI2Ps) to increase the imaging frame rate while preserving the spatial resolution. Two different FOVs are imaged simultaneously and then demixed temporally or computationally. We demonstrate large-scale (500×500 µm2 FOV) multiplane calcium imaging in visual cortex and prefrontal cortex in freely moving mice during spontaneous exploration, social behavior, and auditory stimulus. Furthermore, the increased speed of M-MINI2Ps also enables two-photon voltage imaging at 400 Hz over a 380×150 µm2 FOV in freely moving mice. M-MINI2Ps have compact footprints and are compatible with the open-source MINI2P. M-MINI2Ps, together with their design principles, allow the capture of faster physiological dynamics and population recordings over a greater volume than currently possible in freely moving mice, and will be a powerful tool in systems neuroscience. # Data for: Multiplexed miniaturized two-photon microscopy (M-MINI2Ps) Dataset DOI: [10.5061/dryad.kd51c5bkp](10.5061/dryad.kd51c5bkp) ## Description of the data and file structure Calcium and Voltage imaging datasets from Multiplexed Miniaturized Two-Photon Microscopy (M-MINI2P) ### Files and variables #### File: TM_MINI2P_Voltage_Cranial_VisualCortex.zip **Description:** Voltage imaging dataset acquired in mouse primary visual cortex (V1) using the TM-MINI2P system through a cranial window preparation. This .zip file contains two Tif files, corresponding to the top field of view (FOV) and the bottom field of view (FOV) of the demultiplexed recordings. #### File: TM_MINI2P_Calcium_GRIN_PFC_Auditory_Free_vs_Headfix.zip **Description:** Volumetric calcium imaging dataset from mouse prefrontal cortex (PFC) using the TM-MINI2P system with a GRIN lens implant, comparing neural responses during sound stimulation versus quiet periods, under both freely moving and head-fixed conditions. This .zip file contains 12 Tif files: top and bottom fields of view (FOVs) of the multiplexed recordings at three imaging depths (100 μm, 155 μm, and 240 μm from the end of the implanted GRIN lens), with six files from freely moving conditions and six files from head-fixed conditions. #### File: CM_MINI2P_Calcium_Cranial_VisualCortex_SocialBehavior.zip **Description:** Calcium imaging dataset from mouse primary visual cortex (V1) using the CM-MINI2P system through a cranial window, recorded during social interaction and isolated conditions. This .zip file contains 6 Tif files: multiplexed recordings from the top and bottom fields of view (FOVs), and single-FOV recordings at two imaging depths (170 µm and 250 µm). #### File: TM_MINI2P_Calcium_Cranial_VisualCortex.zip **Description:** Multi-depth calcium imaging dataset from mouse primary visual cortex (V1) using the TM-MINI2P system through a cranial window during spontaneous exploration. This .zip file contains 6 Tif files: demultiplexed recordings from two fields of view (FOV1 and FOV2) at three imaging depths (110 µm, 170 µm, and 230 µm). ## Code/software All datasets are in .tiff format and ImageJ can be used for visualization. Analysis of calcium imaging data and voltage imaging data were analyzed using CaImAn and Volpy, respectively, which are open-source packages available at [https://github.com/flatironinstitute/CaImAn](https://github.com/flatironinstitute/CaImAn).more » « less
An official website of the United States government