Title: Alternate materials for the capture and quantification of gaseous oxidized mercury in the atmosphere
Abstract. Methodologies for identifying atmospheric oxidized mercury (HgII) compounds, including particulate-bound HgII (HgII(p)) and gaseous oxidized mercury (HgII(g)), by mass spectrometry are currently under development. This method requires preconcentration of HgII for analysis due to high instrument detection limits relative to ambient HgII concentrations. The objective of this work was to identify and test materials for quantitative capture of HgII from the gas phase and to suggest potential surfaces onto which HgII can be collected, thermally desorbed, and characterized using mass spectrometry methods. From the literature, several compounds were identified as potential sorbent materials and tested in the laboratory for uptake of gaseous elemental mercury (Hg0) and HgII(g) (permeated from a HgBr2 salt source). Chitosan, α-Al2O3, and γ-Al2O3 demonstrated HgII(g) capture in ambient air laboratory tests, without sorbing Hg0 under the same conditions. When compared to cation exchange membranes (CEMs), chitosan captured a comparable quantity of HgII(g), while ≤90 % of loaded HgII(g) was recovered from α-Al2O3 and γ-Al2O3. When deployed in the field, the capture efficiency of chitosan decreased compared to CEMs, indicating that environmental conditions impacted the sorption efficiency of this material. The poor recovery of HgII from the tested materials compared to CEMs in the field indicates that further identification and exploration of alternative sorbent materials are required to advance atmospheric mercury chemistry analysis by mass spectrometry methods.  more » « less
Award ID(s):
2043042 2044537
PAR ID:
10588749
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
Copernicus Publications on behalf of the European Geosciences Union
Date Published:
Journal Name:
Atmospheric Measurement Techniques
Volume:
17
Issue:
21
ISSN:
1867-8548
Page Range / eLocation ID:
6397 to 6413
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Abstract. Reactive mercury (RM), the sum of both gaseous oxidized Hg and particulatebound Hg, is an important component of the global atmospheric mercury cycle,but measurement currently depends on uncalibrated operationally definedmethods with large uncertainty and demonstrated interferences and artifacts.Cation exchange membranes (CEMs) provide a promising alternative methodologyfor quantification of RM, but method validation and improvements are ongoing.For the CEM material to be reliable, uptake of gaseous elemental mercury(GEM) must be negligible under all conditions and RM compounds must becaptured and retained with high efficiency. In this study, the performance ofCEM material under exposure to high concentrations of GEM (1.43×106 to 1.85×106 pg m−3) and reactive gaseous mercurybromide (HgBr2 ∼5000 pg m−3) was explored using acustom-built mercury vapor permeation system. Quantification of totalpermeated Hg was measured via pyrolysis at 600 ∘C and detectionusing a Tekran® 2537A. Permeation tests wereconducted over 24 to 72 h in clean laboratory air, with absolute humiditylevels ranging from 0.1 to 10 g m−3 water vapor. GEM uptake by the CEMmaterial averaged no more than 0.004 % of total exposure for all testconditions, which equates to a non-detectable GEM artifact for typicalambient air sample concentrations. Recovery of HgBr2 on CEM filters wason average 127 % compared to calculated total permeated HgBr2 based onthe downstream Tekran® 2537A data. The lowHgBr2 breakthrough on the downstream CEMs (< 1 %) suggests thatthe elevated recoveries are more likely related to suboptimal pyrolyzerconditions or inefficient collection on the Tekran® 2537A gold traps. 
    more » « less
  2. null (Ed.)
    A method was developed to measure gaseous oxidized mercury (GOM) air-surface exchange using 2 replicated dynamic flux chambers (DFCs) in conjunction with cation exchange membrane (CEM) filters. The experimental design and method was developed and tested in a laboratory setting, using materials collected from industrial scale open pit gold mines in central Nevada, USA. Materials used included waste rock, heap leach ore, and tailings, with substrate concentrations ranging from 100 to 40000 ng g-1 total mercury (THg). CEM filters were used to capture GOM from the DFC sample lines while a Tekran® 2537A analyzer measured GEM concurrently. Previous and ongoing work has demonstrated that CEM do not collect GEM and efficiently collect multiple compounds of GOM. GOM emission rates up to 4000 pg m- 2 h-1 were measured from tailings materials with high Hg substrate concentrations, and this has significant implication with respect to air-Hg surface exchange. GOM flux was variable for lower Hg concentration substrates, with both emission and deposition observed, and this was affected by ambient air GOM concentrations. For substrates that experienced GOM deposition, deposition velocities were in the range 0.01 – 0.07 cm s-1. 
    more » « less
  3. Accurate measurement of atmospheric reactive mercury (RM) presents analytical challenges due to its reactivity and ultra-trace concentrations. In the last decade, use of the University of Nevada, Reno – Reactive Mercury Active System (RMAS) for RM measurements has increased since it has been shown to be more accurate than the industry standard, the Tekran 2537/1130/1135 system. However, RMAS measurements also have limitations, including long time resolution and sampling biases associated with membranes used for RM sampling. We therefore investigated the use of higher sampling flow rates to reduce sampling time and tested alternative membrane materials using both ambient air sampling and controlled laboratory experiments with a gaseous oxidized mercury (GOM) calibrator. Results indicated that increasing the RMAS sampling flow had a negative impact on determined RM concentrations. RM concentrations at 2 L min−1 were 10% and 30–50% lower than at 1 L min−1 in spring/summer and winter, respectively. However, the chemical composition of RM captured on membranes was not impacted by the increased flow rate. Membranes currently used in the RMAS performed better than numerous alternatives with similar composition, retaining Hg more efficiently. Both ambient air sampling and laboratory experiments revealed that membranes designed to retain only particulate-bound mercury (PBM) also retained significant amounts of GOM. PBM membranes based on borosilicate glass designs retained more than 70% of GOM. 
    more » « less
  4. Abstract. Mercury (Hg) is a global atmospheric pollutant. In its oxidized form (HgII), it can readily deposit to ecosystems, where it may bioaccumulate and cause severe health effects. High HgII concentrations are reported in the free troposphere, but spatiotemporal data coverage is limited. Underestimation of HgII by commercially available measurement systems hinders quantification of Hg cycling and fate. During spring–summer 2021 and 2022, we measured elemental (Hg0) and oxidized Hg using a calibrated dual-channel system alongside trace gases, aerosol properties, and meteorology at the high-elevation Storm Peak Laboratory (SPL) above Steamboat Springs, Colorado. Oxidized Hg concentrations displayed diel and episodic behavior similar to previous work at SPL but were approximately 3 times higher in magnitude due to improved measurement accuracy. We identified 18 multi-day events of elevated HgII (mean enhancement of 36 pg m−3) that occurred in dry air (mean ± SD of relative humidity = 32 ± 16 %). Lagrangian particle dispersion model (HYSPLIT–STILT, Hybrid Single-Particle Lagrangian Integrated Trajectory–Stochastic Time-Inverted Lagrangian Transport) 10 d back trajectories showed that the majority of transport prior to events occurred in the low to middle free troposphere. Oxidized Hg was anticorrelated with Hg0 during events, with an average (± SD) slope of −0.39 ± 0.14. We posit that event HgII resulted from upwind oxidation followed by deposition or cloud uptake during transport. Meanwhile, sulfur dioxide measurements verified that three upwind coal-fired power plants did not influence ambient Hg at SPL. Principal component analysis showed HgII consistently inversely related to Hg0 and generally not associated with combustion tracers, confirming oxidation in the clean, dry free troposphere as its primary origin. 
    more » « less
  5. Abstract. Oxygenated organic molecules (OOMs) play an important role in the formation of atmospheric aerosols. Due to various analytical challenges with respect to measuring organic vapors, uncertainties remain regarding the formation and fate of OOMs. The chemical ionization Orbitrap (CI-Orbitrap) mass spectrometer has recently been shown to be a powerful technique that is able to accurately identify gaseous organic compounds due to its greater mass resolution. Here, we present the ammonium-ion-based CI-Orbitrap (NH4+-Orbitrap) as a technique capable of measuring a wide range of gaseous OOMs. The performance of the NH4+-Orbitrap is compared with that of state-of-the-art mass spectrometers, including a nitrate-ion-based chemical ionization atmospheric pressure interface coupled to a time-of-flight mass spectrometer (NO3--LTOF), a new generation of proton transfer reaction-TOF mass spectrometer (PTR3-TOF), and an iodide-based CI-TOF mass spectrometer equipped with a Filter Inlet for Gases and AEROsols (I−-CIMS). The instruments were deployed simultaneously in the Cosmic Leaving OUtdoors Droplets (CLOUD) chamber at the European Organization for Nuclear Research (CERN) during the CLOUD14 campaign in 2019. Products generated from α-pinene ozonolysis under various experimental conditions were simultaneously measured by the mass spectrometers. The NH4+-Orbitrap was able to identify the widest range of OOMs (i.e., O ≥ 2), from less-oxidized species to highly oxygenated organic molecules (HOMs). Excellent agreement was found between the NH4+-Orbitrap and the NO3--LTOF with respect to characterizing HOMs and with the PTR3-TOF for the less-oxidized monomeric species. OOM concentrations measured by NH4+-Orbitrap were estimated using calibration factors derived from the OOMs with high time-series correlations during the side-by-side measurements. As with the other mass spectrometry techniques used during this campaign, the detection sensitivity of the NH4+-Orbitrap to OOMs is greatly affected by relative humidity, which may be related to changes in ionization efficiency and/or multiphase chemistry. Overall, this study shows that NH4+-ion-based chemistry associated with the high mass resolution of the Orbitrap mass analyzer can measure almost all inclusive compounds. As a result, it is now possible to cover the entire range of compounds, which can lead to a better understanding of the oxidation processes. 