skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


This content will become publicly available on December 10, 2025

Title: Comparative analysis of force sensitive resistor circuitry for use in force myography systems for hand gesture recognition
Wearable technologies for hand gesture classification are becoming increasingly prominent due to the growing need for more natural, human-centered control of complex devices. This need is particularly evident in emerging fields such as virtual reality and bionic prostheses, which require precise control with minimal delay. One method used for hand gesture recognition is force myography (FMG), which utilizes non-invasive pressure sensors to measure radial muscle forces on the skin’s surface of the forearm during hand movements. These sensors, typically force-sensitive resistors (FSRs), require additional circuitry to generate analog output signals, which are then classified using machine learning to derive corresponding control signals for the device. The performance of hand gesture classification can be influenced by the characteristics of this output signal, which may vary depending on the circuitry used. Our study examined three commonly used circuits in FMG systems: the voltage divider (VD), unity gain amplifier (UGA), and transimpedance amplifier (TIA). We first conducted benchtop testing of FSRs to characterize the impact of this circuitry on linearity, deadband, hysteresis, and drift, all metrics with the potential to influence an FMG system’s performance. To evaluate the circuit’s performance in hand gesture classification, we constructed an FMG band with 8 FSRs, using an adjustable Velcro strap and interchangeable circuitry. Wearing the FMG band, participants (N = 15) were instructed to perform 10 hand gestures commonly used in daily living. Our findings indicated that the UGA circuit outperformed others in minimizing hysteresis, drift and deadband with comparable results to the VD, while the TIA circuit excelled in ensuring linearity. Further, contemporary machine learning algorithms used to detect hand gestures were unaffected by the circuitry employed. These results suggest that applications of FMG requiring precise sensing of force values would likely benefit from use of the UGA. Alternatively, if hand gesture state classification is the only use case, developers can take advantage of benefits offered from using less complex circuitry such as the VD.  more » « less
Award ID(s):
2152260
PAR ID:
10609808
Author(s) / Creator(s):
; ; ; ;
Publisher / Repository:
Frontiers
Date Published:
Journal Name:
Frontiers in Electronics
Volume:
5
ISSN:
2673-5857
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Tigrini, Andrea (Ed.)
    Hand gesture classification is crucial for the control of many modern technologies, ranging from virtual and augmented reality systems to assistive mechatronic devices. A prominent control technique employs surface electromyography (EMG) and pattern recognition algorithms to identify specific patterns in muscle electrical activity and translate these to device commands. While being well established in consumer, clinical, and research applications, this technique suffers from misclassification errors caused by limb movements and the weight of manipulated objects, both vital aspects of how we use our hands in daily life. An emerging alternative control technique is force myography (FMG) which uses pattern recognition algorithms to predict hand gestures from the axial forces present at the skin’s surface created by contractions of the underlying muscles. As EMG and FMG capture different physiological signals associated with muscle contraction, we hypothesized that each may offer unique additional information for gesture classification, potentially improving classification accuracy in the presence of limb position and object loading effects. Thus, we tested the effect of limb position and grasped load on 3 different sensing modalities: EMG, FMG, and the fused combination of the two. 27 able-bodied participants performed a grasp and release task with 4 hand gestures at 8 positions and under 5 object weight conditions. We then examined the effects of limb position and grasped load on gesture classification accuracy across each sensing modality. It was found that position and grasped load had statistically significant effects on the classification performance of the 3 sensing modalities and that the combination of EMG and FMG provided the highest classification accuracy of hand gesture, limb position, and grasped load combinations (97.34%) followed by FMG (92.27%) and then EMG (82.84%). This points to the fact that the addition of FMG to traditional EMG control systems offers unique additional data for more effective device control and can help accommodate different limb positions and grasped object loads. 
    more » « less
  2. Carbon nanotube (CNT) field-effect transistors (CNFETs) promise significant energy efficiency benefits versus today's silicon-based FETs. Yet despite this promise, complementary (CMOS) CNFET analog circuitry has never been experimentally demonstrated. Here we show the first reported demonstration of full CNFET CMOS analog circuits. For characterization, we fabricate analog building block circuits: multiple instances of two-stage op-amps. These CNFET CMOS op-amps achieve gain >700 (maximum derivative of output voltage with respect to differential input voltage), operate at a scaled sub- 500 mV supply voltage, achieve high linearity (even when operating at these scaled voltages), and are robust over time (minimal drift over >10,000 cycled measurements over 12 hours). Additionally, we demonstrate a front-end analog sub-system that integrates a CNFET-based breath sensor with an analog sensor interface circuit (transimpedance amplifier followed by a voltage follower to convert resistance change of the chemoresistive CNFET sensor into a buffered output voltage). These experimental demonstrations are the first reports of CNFET CMOS analog functionality that is essential for a future CNT CMOS technology. 
    more » « less
  3. Abstract Objective. Intracortical brain–computer interfaces (iBCIs) have demonstrated the ability to enable point and click as well as reach and grasp control for people with tetraplegia. However, few studies have investigated iBCIs during long-duration discrete movements that would enable common computer interactions such as ‘click-and-hold’ or ‘drag-and-drop’.Approach. Here, we examined the performance of multi-class and binary (attempt/no-attempt) classification of neural activity in the left precentral gyrus of two BrainGate2 clinical trial participants performing hand gestures for 1, 2, and 4 s in duration. We then designed a novel ‘latch decoder’ that utilizes parallel multi-class and binary decoding processes and evaluated its performance on data from isolated sustained gesture attempts and a multi-gesture drag-and-drop task.Main results. Neural activity during sustained gestures revealed a marked decrease in the discriminability of hand gestures sustained beyond 1 s. Compared to standard direct decoding methods, the Latch decoder demonstrated substantial improvement in decoding accuracy for gestures performed independently or in conjunction with simultaneous 2D cursor control.Significance. This work highlights the unique neurophysiologic response patterns of sustained gesture attempts in human motor cortex and demonstrates a promising decoding approach that could enable individuals with tetraplegia to intuitively control a wider range of consumer electronics using an iBCI. 
    more » « less
  4. Abstract Objective. Muscle network modeling maps synergistic control during complex motor tasks. Intermuscular coherence (IMC) is key to isolate synchronization underlying coupling in such neuromuscular control. Model inputs, however, rely on electromyography, which can limit the depth of muscle and spatial information acquisition across muscle fibers.Approach. We introduce three-dimensional (3D) muscle networks based on vibrational mechanomyography (vMMG) and IMC analysis to evaluate the functional co-modulation of muscles across frequency bands in concert with the longitudinal, lateral, and transverse directions of muscle fibers. vMMG is collected from twenty subjects using a bespoke armband of accelerometers while participants perform four hand gestures. IMC from four superficial muscles (flexor carpi radialis, brachioradialis, extensor digitorum communis, and flexor carpi ulnaris) is decomposed using matrix factorization into three frequency bands. We further evaluate the practical utility of the proposed technique by analyzing the network responses to various sensor-skin contact force levels, studying changes in quality, and discriminative power of vMMG.Main results. Results show distinct topological differences, with coherent coupling as high as 57% between specific muscle pairs, depending on the frequency band, gesture, and direction. No statistical decrease in signal strength was observed with higher contact force.Significance. Results support the usability vMMG as a tool for muscle connectivity analyses and demonstrate the use of IMC as a new feature space for hand gesture classification. Comparison of spectrotemporal and muscle network properties between levels of force support the robustness of vMMG-based network models to variations in tissue compression. We argue 3D models of vMMG-based muscle networks provide a new foundation for studying synergistic muscle activation, particularly in out-of-clinic scenarios where electrical recording is impractical. 
    more » « less
  5. null (Ed.)
    This paper presents a motion-sensing device with the capability of harvesting energy from low-frequency motion activities that can be utilized for long-term human health monitoring. The energy harvester used in the proposed motion sensor is based on the mechanical modulation of liquid on an insulated electrode, which utilizes a technique referred to as reverse electrowetting-on-dielectric (REWOD). The generated AC signal from the REWOD is rectified to a DC voltage using a Schottky diode-based rectifier and boosted subsequently with the help of a linear charge-pump circuit and a low-dropout regulator (LDO). The constant DC voltage from the LDO (1.8 V) powers the motion-sensing read-out circuitry, which converts the generated charge into a proportional output voltage using a charge amplifier. After amplification of the motion data, a 5-bit SAR-ADC (successive-approximation register ADC) digitizes the signal to be transmitted to a remote receiver. Both the CMOS energy harvester circuit including the rectifier, the charge-pump circuit, the LDO, and the read-out circuit including the charge amplifier, and the ADC is designed in the standard 180 nm CMOS technology. The amplified amplitude goes up to 1.76 V at 10 Hz motion frequency, following linearity with respect to the frequency. The generated DC voltage from the REWOD after the rectifier and the charge-pump is found to be 2.4 V, having the voltage conversion ratio (VCR) as 32.65% at 10 Hz of motion frequency. The power conversion efficiency (PCE) of the rectifier is simulated as high as 68.57% at 10 Hz. The LDO provides the power supply voltage of 1.8 V to the read-out circuit. The energy harvester demonstrates a linear relationship between the frequency of motion and the generated output power, making it suitable as a self-powered wearable motion sensor. 
    more » « less