Attention:The NSF Public Access Repository (PAR) system and access will be unavailable from 11:00 PM ET on Thursday, November 12th until 12:00 AM ET on Friday, November 13th due to maintenance. We apologize for the inconvenience.


Title: Characterization of Silicon Photomultiplier Photon Detection Efficiency at Liquid Nitrogen Temperature
Abstract The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect scintillation light either directly or after it has been wavelength-shifted. Maximizing the photon detection efficiency (PDE) of the SiPMs used in these experiments optimizes the sensitivity to new physics; however, the PDEs of commercial SiPMs, although well known at room temperature, are not well characterized at the cryogenic temperatures at which many experiments operate them. Here we present results from an experimental setup that measures the photon detection efficiencies of silicon photomultipliers at liquid nitrogen temperature, 77 K. Results from a KETEK PM3325-WB-D0 and a Hamamatsu S13360-3050CS silicon photomultiplier — of R&D interest to the LEGEND experiment — exhibit a decrease in photon detection efficiency greater than 20% at liquid nitrogen temperature relative to room temperature for 562 nm light.  more » « less
Award ID(s):
1812374 2209530
PAR ID:
10610891
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
IOP Publishing
Date Published:
Journal Name:
Journal of Instrumentation
Volume:
19
Issue:
12
ISSN:
1748-0221
Page Range / eLocation ID:
P12014
Subject(s) / Keyword(s):
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract The DarkSide-20k (DS-20k) experiment, currently under construction at the Gran Sasso National Laboratory (LNGS), represents a significant advancement in the field of direct Dark Matter (DM) detection. Utilizing a dual-phase Liquid Argon Time Projection Chamber (LArTPC) DS-20k is designed to extend the sensitivity limits in the search for Weakly Interacting Massive Particles (WIMPs), a leading DM candidate. A crucial component of the experiment is the active veto system, which acts as a shield against external and instrumental background sources, minimizing background and enhancing accuracy of DM detection. The system features innovative near-UV cryogenic Silicon PhotoMultipliers (SiPMs) for light readout. Universities and research institutes in the UK and Poland are responsible for producing and testing the veto Photon-Detection Units (vPDUs) that will be fitted on the Inner and Outer Veto. This paper presents the status of the production and characterization of the vPDUs, along with the quality assurance and quality control (QA/QC) procedures implemented to ensure the reliability and efficiency of the photon-detection systems. 
    more » « less
  2. Abstract Silicon photomultipliers (SiPMs) are a compelling alternative to photomultipliers in cryogenic ultra-low background applications, such as in dark matter direct search experiments. Working on the next generation of dark matter direct search experiments, the Global Argon Dark Matter Collaboration has committed to this technology, starting from their next programmed experiment: DarkSide-20k. The development of a cryogenic SiPM-based photon detector has been a challenging task due to the strict radiopurity requirements and cryogenic conditions imposed by the expected signature for dark matter signals. The R&D culminated with the design of the Photon Detector Unit (PDU), a modular photon detector of 20x20 cm2with 4 readout channels, based on a SiPM technology developed by Fondazione Bruno Kessler and cryogenic front-end electronics; more than 500 PDUs will be used to construct the two ∼10.5 m2optical planes of the massive two-phase argon time projection chamber (TPC) of DarkSide-20k and as photosensors for its veto systems. 
    more » « less
  3. Abstract The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (VBD), the SiPM gain (gSiPM), the rate of change ofgSiPMwith respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (PCA) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate VBDto tens of mV precision and DCR close to Poissonian error. The temperature dependence of VBDwas found to be 56 ± 2 mV K-1, andmon average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 103e-PE-1V-1. The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K-1corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of PCAwas estimated to be 4000 ± 1000 ppm K-1. PCAestimated from the average across all SiPMs is a better estimator than the PCAcalculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio. 
    more » « less
  4. The application of silicon photomultiplier (SiPM) technology for weak-light detection at a single photon level has expanded thanks to its better photon detection efficiency in comparison to a conventional photomultiplier tube (PMT). SiPMs with large detection area have recently become commercially available, enabling applications where the photon flux is low both temporarily and spatially. On the other hand, several drawbacks exist in the usage of SiPMs such as a higher dark count rate, many readout channels, slow response time, and optical crosstalk; therefore, users need to carefully consider the trade-offs. This work presents a SiPM-embedded compact large-area photon detection module. Various techniques are adopted to overcome the disadvantages of SiPMs so that it can be generally utilized as an upgrade from a PMT. A simple cooling component and recently developed optical crosstalk suppression method are adopted to reduce the noise which is more serious for larger-area SiPMs. A dedicated readout circuit increases the response frequency and reduces the number of readout channels. We favorably compare this design with a conventional PMT and obtain both higher photon detection efficiency and larger-area acceptance. 
    more » « less
  5. Abstract Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0 $$\nu \beta \beta $$ ν β β ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0 $$\nu \beta \beta $$ ν β β of $$^{136}$$ 136 Xe with projected half-life sensitivity of $$1.35\times 10^{28}$$ 1.35 × 10 28  yr. To reach this sensitivity, the design goal for nEXO is $$\le $$ ≤ 1% energy resolution at the decay Q -value ( $$2458.07\pm 0.31$$ 2458.07 ± 0.31  keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q -value for the nEXO design. 
    more » « less