skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


This content will become publicly available on April 9, 2026

Title: Ligand design for 227 Ac extraction by active learning and molecular topology
An active learning workflow that combines electronic structure and molecular topology was developed for the in silico design of organic ligands for actinium capture in solution.  more » « less
Award ID(s):
2143354
PAR ID:
10617537
Author(s) / Creator(s):
;
Publisher / Repository:
RSC
Date Published:
Journal Name:
Digital Discovery
Volume:
4
Issue:
4
ISSN:
2635-098X
Page Range / eLocation ID:
1100 to 1112
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. We report on spectroscopic measurements on the 4f76s28S7/2−4f7(8S)6s6p(1P)8P5/2,7/2transitions at 466.32 nm and 462.85 nm, respectively, in neutral europium-151 and europium-153. The center of gravity frequencies for the 151 and 153 isotopes for both transitions are reported for the first time using saturated absorption spectroscopy. For the 6s6p(1P)8P5/2state, the center of gravity frequencies were found to be 642,894,493.3(4) MHz and 642,891,693.3(9) MHz for the 151 and 153 isotopes, respectively. The hyperfine constants for the upper state were found to beA(151)=−157.01(3)MHz,B(151)=74.5(4)MHz andA(153)=−69.43(14)MHz,B(153)=191.0(26)MHz. These hyperfine values are all consistent with previously published results except forB(151) that has a small discrepancy. The isotope shift was found to be 2799.54(20) MHz, a small discrepancy with previously published results. For the 6s6p(1P)8P7/2state, the center of gravity frequencies were found to be 647,708,930.6(6) MHz and 647,705,958.4(26) MHz for the 151 and 153 isotopes, respectively. The hyperfine constants for the upper state were found to beA(151)=−218.66(4)MHz,B(151)=−293.4(8)MHz andA(153)=−97.15(13)MHz,B(153)=−750(3)MHz. These values are all consistent with previously published results except forA(151) that has a small discrepancy. The isotope shift was found to be 2972.8(5) MHz, a small discrepancy with previously measured results. 
    more » « less
  2. Abstract We calculate cross sections for fine-structure transitions of Ne+, Ar+, Ne2+, and Ar2+in collisions with atomic hydrogen by using quantum-mechanical methods. Relaxation rate coefficients are calculated for temperatures up to 10,000 K. The temperature-dependent critical densities for the relaxation of Ne+, Ar+, Ne2+, and Ar2+in collisions with H have been determined and compared to the critical densities for collisions with electrons. The present calculations will be useful for studies utilizing the infrared lines [Neii] 12.8, [Neiii] 15.6, [Neiii] 36.0, [Arii] 6.99, [Ariii] 8.99, and [Ariii] 21.8μm as diagnostics of, for example, planetary nebulae and star formation. 
    more » « less
  3. Abstract The abundance and distribution of44Ti tells us about the nature of the core-collapse supernovae explosions. There is a need to understand the nuclear reaction network creating and destroying44Ti in order to use it as a probe for the explosive mechanism. The44Ti(α, p)47V reaction is a very important reaction and it controls the destruction of44Ti. Difficulties with direct measurements have led to an attempt to study this reaction indirectly. Here, the first step of the indirect study which is the identification of levels of the compound nucleus48Cr is presented. A 100-MeV proton beam was incident on a50Cr target. States in48Cr were populated in the50Cr(p, t)48Cr reaction. The tritons were momentum-analysed in the K600 Q2D magnetic spectrometer at iThemba LABS. 
    more » « less
  4. Abstract Multiplex imaging in the second near‐infrared window (NIR‐II, 1000–1700 nm) provides exciting opportunities for more precise understanding of biological processes and more accurate diagnosis of diseases by enabling real‐time acquisition of images with improved contrast and spatial resolution in deeper tissues. Today, the number of imaging agents suitable for this modality remains very scarce. In this work, we have synthesized and fully characterized, including theoretical calculations, a series of dimeric LnIII/GaIIImetallacrowns bearing RuIIpolypyridyl complexes,LnRu‐3(Ln=YIII, YbIII, NdIII, ErIII). Relaxed structures ofYRu‐3in the ground and the excited electronic states have been calculated using dispersion‐corrected density functional theory methods. Detailed photophysical studies ofLnRu‐3have demonstrated that characteristic emission signals of YbIII, NdIIIand ErIIIin the NIR‐II range can be sensitized upon excitation in the visible range through RuII‐centered metal‐to‐ligand charge transfer (MLCT) states. We have also showed that these NIR‐II signals are unambiguously detected in an imaging experiment using capillaries and biological tissue‐mimicking phantoms. This work opens unprecedented perspectives for NIR‐II multiplex imaging using LnIII‐based molecular compounds. 
    more » « less
  5. Jeans, D; Tian, J (Ed.)
    Our recent work has shown that a novel much higher granularity forward calorimetry concept can enable much more detailed and precise reconstruction than the baseline designs based on LEP luminometers, along with the capability of electron/positron/photon separation. This new calorimeter concept is designed primarily to maximize the acceptance for e+e→ γγ as an alternative luminosity process, where it serves to define the inner edge of the acceptance (there is no outer edge, as the complete detector is used in the measurement), while continuing to provide the standard luminosity measurement from small-angle Bhabha scattering (SABS). It will also serve as a general forward electromagnetic calorimeter helping ensure hermeticity and detecting individual electrons, positrons, and photons. In this contribution we highlight the Bhabha rejection capability in the context of the e+e→ γγ luminosity measurement and motivate the utility of a Bhabha “mini-tracker” consisting of a few planes of upstream thin silicon detectors. This could further refine the e+/epolar angle measurement, aid with charge measurement, improve Bhabha rejection (for γγ), and, last-but-not-least, help mitigate the beam-induced electromagnetic deflection that biases the Bhabha acceptance by providing high precision longitudinal vertex information in Bhabha events, which can be used to diagnose this effect of the beam on the final-state electron and positron. 
    more » « less