Healthy human locomotion functions with good gait symmetry depend on rhythmic coordination of the left and right legs, which can be deteriorated by neurological disorders like stroke and spinal cord injury. Powered exoskeletons are promising devices to improve impaired people's locomotion functions, like gait symmetry. However, given higher uncertainties and the time-varying nature of human-robot interaction, providing personalized robotic assistance from exoskeletons to achieve the best gait symmetry is challenging, especially for people with neurological disorders. In this paper, we propose a hierarchical control framework for a bilateral hip exoskeleton to provide the adaptive optimal hip joint assistance with a control objective of imposing the desired gait symmetry during walking. Three control levels are included in the hierarchical framework, including the high-level control to tune three control parameters based on a policy iteration reinforcement learning approach, the middle-level control to define the desired assistive torque profile based on a delayed output feedback control method, and the low-level control to achieve a good torque trajectory tracking performance. To evaluate the feasibility of the proposed control framework, five healthy young participants are recruited for treadmill walking experiments, where an artificial gait asymmetry is imitated as the hemiparesis post-stroke, and only the ‘paretic’ hip joint is controlled with the proposed framework. The pilot experimental studies demonstrate that the hierarchical control framework for the hip exoskeleton successfully (asymmetry index from 8.8% to − 0.5%) and efficiently (less than 4 minutes) achieved the desired gait symmetry by providing adaptive optimal assistance on the ‘paretic’ hip joint.
more »
« less
Characterization of Hip Abduction Exoskeleton for Assistance During Gait Perturbations
Robotic lower limb exoskeletons have been shown to successfully provide joint torques to assist human subjects during walking. Assisting the wearer during gait perturbations to prevent falls still poses a challenge due to specific requirements of the device, and complex bipedal dynamics of recovery. In this study, we present a hip exoskeleton device with pneumatically actuated abduction/adduction motion to provide hip torque for assisting with lateral balance. The device was designed to be wearable, allow integration with previously developed wearable gait perturbation detection system and knee exoskeleton, and produce fast actuation to provide assistive joint torque during gait perturbations. We present the results of the experimental benchtop tests of the device. The maximum torque output and rate of torque development were characterized using a load cell. The maximum angular displacement, with added weights to simulate the leg inertia, was recorded using an inertial measurement unit sensor. Lastly, a preliminary test on a human subject demonstrated that the device, when exerting instantaneous hip abduction torque during swing walking gait, can effectively modify foot placement in the lateral direction. This work contributes towards developing exoskeleton control strategies for assistance during gait perturbations to prevent falls.
more »
« less
- Award ID(s):
- 2301816
- PAR ID:
- 10629904
- Publisher / Repository:
- IEEE
- Date Published:
- ISSN:
- 2159-6255
- ISBN:
- 979-8-3503-5536-9
- Page Range / eLocation ID:
- 70 to 75
- Format(s):
- Medium: X
- Location:
- Boston, MA, USA
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Robot assisted gait retraining is an increasingly common method for supporting restoration of walking function after neurological injury. Gait speed, an indicator of walking function, is correlated with propulsive force, a measure modulated by the posture of the trailing limb at push-off. With the ultimate goal of improving efficacy of robot assisted gait retraining, we sought to directly target gait propulsion, by exposing subjects to pulses of joint torque applied at the hip and knee joints to modulate push-off posture. In this work, we utilized a robotic exoskeleton to apply pulses of torque to the hip and knee joints, during individual strides, of 16 healthy control subjects, and quantified the effects of this intervention on hip extension and propulsive impulse during and after application of these pulses. We observed significant effects in the outcome measures primarily at the stride of pulse application and generally no after effects in the following strides. Specifically, when pulses were applied at late stance, we observed a significant increase in propulsive impulse when knee and/or hip flexion pulses were applied and a significant increase in hip extension angle when hip extension torque pulses were applied. When pulses were applied at early stance, we observed a significant increase in propulsive impulse associated with hip extension torque.more » « less
-
High-performance actuators are crucial to enable mechanical versatility of wearable robots, which are required to be lightweight, highly backdrivable, and with high bandwidth. State-of-the-art actuators, e.g., series elastic actuators (SEAs), have to compromise bandwidth to improve compliance (i.e., backdrivability). We describe the design and human-robot interaction modeling of a portable hip exoskeleton based on our custom quasi-direct drive (QDD) actuation (i.e., a high torque density motor with low ratio gear). We also present a model-based performance benchmark comparison of representative actuators in terms of torque capability, control bandwidth, backdrivability, and force tracking accuracy. This paper aims to corroborate the underlying philosophy of “design for control“, namely meticulous robot design can simplify control algorithms while ensuring high performance. Following this idea, we create a lightweight bilateral hip exoskeleton to reduce joint loadings during normal activities, including walking and squatting. Experiments indicate that the exoskeleton is able to produce high nominal torque (17.5 Nm), high backdrivability (0.4 Nm backdrive torque), high bandwidth (62.4 Hz), and high control accuracy (1.09 Nm root mean square tracking error, 5.4% of the desired peak torque). Its controller is versatile to assist walking at different speeds and squatting. This work demonstrates performance improvement compared with state-of-the-art exoskeletons.more » « less
-
Powered exoskeletons for gait rehabilitation and mobility assistance are currently available for the adult population and hold great promise for children with mobility limiting conditions. Described here is the development and key features of a modular, lightweight and customizable powered exoskeleton for assist-as-needed overground walking and gait rehabilitation. The pediatric lower-extremity gait system (PLEGS) exoskeleton contains bilaterally active hip, knee and ankle joints and assist-as-needed shared control for young children with lower-limb disabilities such as those present in the Cerebral Palsy, Spina Bifida and Spinal Cord Injured populations. The system is comprised of six joint control modules, one at each hip, knee and ankle joint. The joint control module, features an actuator and motor driver, microcontroller, torque sensor to enable assist-as-needed control, inertial measurement unit and system monitoring sensors. Bench-testing results for the proposed joint control module are also presented and discussed.more » « less
-
Abstract Series elastic actuators (SEAs) are increasingly popular in wearable robotics due to their high fidelity closed-loop torque control capability. Therefore, it has become increasingly important to characterize its performance when used in dynamic environments. However, the conventional design approach does not fully capture the complexity of the entire exoskeleton system. These limitations stem from identifying design criteria with inadequate biomechanics data, utilizing an off-the-shelf user interface, and applying a benchtop-based proportional-integral-derivative control for actual low-level torque tracking. While this approach shows decent actuator performance, it does not consider human factors such as the dynamic back-driving nature of human-exoskeleton systems as well as soft human tissue dampening during the load transfer. Using holistic design guidelines to improve the SEA-based exoskeleton performance during dynamic locomotion, our final system has an overall mass of 4.8 kg (SEA mass of 1.1 kg) and can provide a peak joint torque of 108 Nm with a maximum velocity of 5.2 rad/s. Additionally, we present a user state-based feedforward controller to further improve the low-level torque tracking for diverse walking conditions. Our study results provide future exoskeleton designers with a foundation to further improve SEA-based exoskeleton’s torque tracking response for maximizing human-exoskeleton performance during dynamic locomotion.more » « less
An official website of the United States government