Falsified antimalarial pharmaceuticals are a worldwide problem with negative public health implications. Here, we develop a surface-enhanced Raman scattering (SERS) protocol to recognize substandard and falsified antimalarial drugs present in commercially available tablets. After recording SERS spectra for pure chloroquine, primaquine, and doxycycline, SERS is used to measure these drugs formulated as active pharmaceutical ingredients (APIs) in the presence of common pharmaceutical caplet excipients. To demonstrate the viability of our approach, a red team study was also performed where low-quality and falsified formulations of all three drugs presented as unknowns were identified. These data in conjunction with promising results from a portable Raman spectrometer suggest that SERS is a viable technique for on-site analysis of drug quality.
more »
« less
This content will become publicly available on August 19, 2026
Disintegration Fingerprinting: A low-cost and easy-to-use tool for identifying substandard and falsified medicines
There is an urgent need for low-cost and simple-to-use tools for identifying substandard and falsified medicines. In this work we demonstrate “Disintegration Fingerprinting” (DF), a technique that identifies pills, tablets, caplets, and other solid-dosage drugs based on how the drug disintegrates and dissolves in liquid. The DF hardware consists of a water-filled transparent plastic cup atop a conventional magnetic stirrer. An inexpensive sensor mounted on the outside of the cup shines infrared light into the cup and measures the amount of light that is reflected back to the sensor. When a pill is added to the stirred water, the pill begins to disintegrate into particles that swirl around inside the cup. Whenever one of these particles passes near the infrared sensor, the particle reflects additional light back to the sensor and creates a millisecond-duration peak in a plot of sensor output vs. time. The number of particles in the water changes over time as the particles continue to disintegrate and (in some cases) eventually dissolve away. By plotting the number of particles detected vs. time, we create a Disintegration Fingerprint that can be used to identify the drug product. In a proof-of-concept study, we used DF to analyze 96 pills from 32 different drug products (including antibiotics, opioid and non-opioid analgesics, antidepressants, anti-inflammatories, antiemetics, antihistamines, decongestants, muscle relaxants, expectorants, sleep aids, cold medicines, antacids, hormonal birth control, and dietary supplements, as well as a simulated falsified drug product). We found that DF correctly identified 90% of these pills, and the technique can even distinguish name-brand and generic versions of the same drug. By providing a fast (60-minute), inexpensive ($33 USD), and easy-to-use tool for identifying substandard and falsified medicines, Disintegration Fingerprinting can play an important role in the fight against fake drugs.
more »
« less
- PAR ID:
- 10638794
- Publisher / Repository:
- medRxiv
- Date Published:
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Substandard and falsified pharmaceuticals, prevalent in low- and middle-income countries, substantially increase levels of morbidity, mortality and drug resistance. Regulatory agencies combat this problem using post-market surveillance by collecting and testing samples where consumers purchase products. Existing analysis tools for post-market surveillance data focus attention on the locations of positive samples. This article looks to expand such analysis through underutilized supply-chain information to provide inference on sources of substandard and falsified products. We first establish the presence of unidentifiability issues when integrating this supply-chain information with surveillance data. We then develop a Bayesian methodology for evaluating substandard and falsified sources that extracts utility from supply-chain information and mitigates unidentifiability while accounting for multiple sources of uncertainty. Using de-identified surveillance data, we show the proposed methodology to be effective in providing valuable inference.more » « less
-
This research paper describes the design of a device that can assist seniors or people with physical or cognitive limitations to take their prescribed medications that are in the form of pills on time while verifying that such pills have been actually consumed. The design consists of a portable smart pill dispenser that will rest on a base, allowing it to dispense pills into a smart cup. The smart pill dispenser uses a stepper motor to rotate to a desired pills based on a specific time slot/day of the week. The smart cup attached to the pill box uses an accelerometer, gyroscope, and an IR proximity sensor to detect if a user is taking the medication by how much the smart cup is lifted and tilted. The smart cup will inform the smart pill dispenser if the pills are properly consumed or not, thus, allowing the device to potentially aid the patients to have a healthier life.more » « less
-
ABSTRACT: Near-infrared (NIR) spectroscopy is a promising technique for field identification of substandard and falsified drugs because it is portable, rapid, nondestructive, and can differentiate many formulated pharmaceutical products. Portable NIR spectrometers rely heavily on chemometric analyses based on libraries of NIR spectra from authentic pharmaceutical samples. However, it is difficult to build comprehensive product libraries in many low- and middle-income countries due to the large numbers of manufacturers who supply these markets, frequent unreported changes in materials sourcing and product formulation by the manufacturers, and general lack of cooperation in providing authentic samples. In this work, we show that a simple library of lab-formulated binary mixtures of an active pharmaceutical ingredient (API) with two diluents gave good performance on field screening tasks, such as discriminating substandard and falsified formulations of the API. Six data analysis models, including principal component analysis and supportvector machine classification and regression methods and convolutional neural networks, were trained on binary mixtures of acetaminophen with either lactose or ascorbic acid. While the models all performed strongly in cross-validation (on formulations similar to their training set), they individually showed poor robustness for formulations outside the training set. However, a predictive algorithm based on the six models, trained only on binary samples, accurately predicts whether the correct amount of acetaminophen is present in ternary mixtures, genuine acetaminophen formulations, adulterated acetaminophen formulations, and falsified formulations containing substitute APIs. This data analytics approach may extend the utility of NIR spectrometers for analysis of pharmaceuticals in low-resource settings.more » « less
-
PURPOSE A postmarket evaluation of chemotherapy dosage forms in Ethiopia was conducted to test the accuracy of the chemoPAD, a paper analytical device for drug quality screening. MATERIALS AND METHODS In September of 2018 in Addis Ababa, Ethiopia, 41 anticancer drug dosage forms (representing 4 active ingredients, 5 brands, and 7 lot numbers) were collected and were rapidly screened for quality using a chemotherapy paper analytical device (chemoPAD). Confirmatory analysis via high performance liquid chromatography was conducted. RESULTS The chemoPAD showed that the correct active pharmaceutical ingredient was present in doxorubicin, methotrexate, and oxaliplatin injectable dosage forms. However, 11 of 20 cisplatin samples failed the screening test. Confirmatory assay by high-performance liquid chromatography showed that all 20 cisplatin samples—comprising three lot numbers of a product stated to be Cisteen—were substandard, containing on average 54% ± 6% of the stated cisplatin content. Inductively coupled plasma optical emission spectroscopy analysis of five representative samples found 57% to 71% of the platinum that should have been present. The sensitivity of the chemoPAD for detection of falsified products could not be measured (as none were present in these samples), but the selectivity was 100% (no false positives). The sensitivity for detection of substandard products was 55%, and the selectivity was 100% (no false positives). CONCLUSION Although instrumental analysis by pharmacopeia methods must remain the gold standard for assessing overall drug quality, these methods are time consuming and patients could be exposed to a bad-quality drug while clinical workers wait for testing to be performed. The chemoPAD technology could allow clinicians to check at the point of use for serious problems in the quality of chemotherapy drugs on a weekly or monthly schedule.more » « less