High-voltage transmission lines are the backbone of modern power systems, facilitating the delivery of electricity from diverse generation sources, including conventional power plants and renewable energy systems, to consumers. As the electricity demand grows, the expansion of transmission infrastructure becomes essential to connecting new consumers with power suppliers. However, traditional transmission lines require significant right-of-way, posing challenges related to land use and environmental impact, as well as limited loadability. To address this issue, compact unconventional High Surge Impedance Loading (HSIL) transmission lines offer a viable solution by reducing right-of-way requirements while enhancing line natural power, mainly leading to less voltage drop. Before the implementation of the new unconventional HSIL lines, it is crucial to assess key parameters, such as magnetic field distribution under the lines, to ensure compliance with environmental and safety standards. This paper presents a numerical analysis of the magnetic field characteristics of compact unconventional HSIL transmission lines with different subconductor configurations. The results show that the proposed HSIL designs can reduce the magnetic field at ground level by up to 71.74% compared to a conventional 500 kV line near the center, as well as by up to 74% at the right-of-way edge, while maintaining magnetic field levels well below the limits set by ICNIRP and state-specific regulations. This study evaluates the magnetic field distribution within the right-of-way, providing insights into the electromagnetic performance and potential implications for transmission line design.
more »
« less
Determining the Minimum Phase‐to‐Phase Gap Distance for Unconventional Transmission Lines Using Numerical Method
ABSTRACT With the increasing demand for power transmission, compact, high surge impedance loading (HSIL) high‐voltage transmission lines have emerged as a viable solution due to their reduced land acquisition costs and higher power delivery capability. The compactness of a transmission line depends on effective insulation coordination, particularly in determining the phase‐to‐phase clearance, which is governed by the critical flashover voltage under switching and lightning overvoltage conditions. Traditional methods for phase‐to‐phase clearance rely on empirical formulas derived from experimental data, which are convenient for conventional high‐voltage lines. However, unconventional HSIL lines require a faster and more adaptable evaluation method, as they involve optimized conductor positioning to reduce right‐of‐way requirements while enhancing natural power loadability. This study presents a simplified numerical approach to determine the minimum phase‐to‐phase gap, utilizing arc propagation viability curves, and offers an efficient alternative to conventional empirical methods. The proposed method was successfully applied to a 500 kV conventional line as well as 500 and 735 kV unconventional line designs, demonstrating its capability in accurately assessing insulation requirements. Results reveal that the method can support reduced gap clearances while still maintaining reliability, thereby validating its usefulness in optimizing compact transmission line configurations.
more »
« less
- Award ID(s):
- 2306098
- PAR ID:
- 10644477
- Publisher / Repository:
- DOI PREFIX: 10.1049
- Date Published:
- Journal Name:
- IET Generation, Transmission & Distribution
- Volume:
- 19
- Issue:
- 1
- ISSN:
- 1751-8687
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Transmission expansion planning (TEP) plays a vital role in ensuring the reliable and efficient operation of power systems, especially with the growing demand for electricity and the integration of renewable energy sources. This paper focuses on applying unconventional high surge impedance loading (HSIL) lines in transmission expansion planning and compares their outcomes with conventional line-based transmission expansion planning. Starting with a 17 bus- 500 kV power system connected by a conventional transmission line, the objective is to connect a new load located in a new bus, bus #18, to the existing 17-bus power system via two approaches: using conventional lines and incorporating unconventional HSIL lines. By comparing the number of lines required for the conventional and unconventional approaches, maintaining almost identical conductor volume per circuit, the effectiveness of unconventional HSIL lines in TEP is evaluated where using only two unconventional HSIL lines is sufficient to connect 1000 MW load demand at bus 18 while three lines are required when using the conventional design.more » « less
-
Transmission expansion planning (TEP) is crucial for maintaining the reliable and efficient operation of the power systems, particularly in the face of increasing electricity demand and the integration of renewable energy sources. This paper aims to investigate the application of unconventional high surge impedance loading (HSIL) lines in TEP and presents a comparative analysis of their outcomes against conventional line-based TEP approaches. Starting with a 17-bus 500 kV test system, which can operate well under normal operating condition as well as all single contingency conditions, the objective is to connect a new load located in a new bus, bus #18, to the existing test system via two approaches: using conventional lines and incorporating unconventional HSIL lines. By comparing the number of lines required for the conventional and unconventional approaches, maintaining identical conductor weight per circuit, the effectiveness of unconventional HSIL lines in TEP is evaluated where using only two unconventional HSIL lines is sufficient to connect 1250 MW load demand at bus 18 while three transmission lines are required when using the conventional line. Finally, a thorough economic analysis has been conducted on both TEP scenarios, revealing that implementing unconventional HSIL lines leads to remarkable cost savings and thus can be considered a promising option for TEP studies.more » « less
-
This paper presents a 17-bus 500 kV test system for transmission expansion planning (TEP) studies. An actual 500 kV transmission line geometry was used for the overhead lines of this system. Although many test systems have been introduced for different types of power system analysis, those especially for TEP studies at a transmission voltage level, not distribution voltage level, are few. To the best of our knowledge, the introduced test systems for TEP studies, either those combined with electricity market problems or those used to connect a new load or generation to an existing power grid, consider the studies under only normal condition. However, for TEP studies it is needed that a test system meets voltage drop and line loading limits criteria under normal condition as well as all single contingencies, and in this regard, addressing the latter, all single contingencies, is challenging. This paper addresses this technical gap, introducing a 17-bus test system at a transmission voltage level, 500 kV, that meets requirements under normal condition as well as all single contingencies. In addition to presenting all details of this new test system, load flow results under normal condition as well as the worst single contigency are presented. For studies on the TEP, this test system can be an invaluable resource.more » « less
-
This paper introduces a 17-bus 500 kV test system intended for transmission expansion planning (TEP) studies. The overhead lines used in the system are based on an actual 500 kV transmission line geometry. Although several test systems have been developed for various forms of power system analysis, few are specifically tailored for TEP studies at the transmission voltage level, as opposed to the distribution voltage level. Current test systems for TEP studies are limited to single loading conditions only for normal operating conditions, and the majority of these systems are intertwined with issues related to the energy market or devised specifically for integrating new generations and loads into the existing power systems. However, ensuring a test system satisfies both voltage drop and line loading criteria during both normal and all single contingency operations is crucial in TEP studies, and addressing these issues under contingency conditions poses notable challenges. Moreover, practical TEP scenarios involve varied loadings, including peak load and dominant loading (60% of peak load) scenarios, while the existing test systems are configured solely for single loading conditions. To address these technical gaps, this paper introduces the 17-bus test system operating at a transmission voltage level of 500 kV, meeting technical requirements under normal and all single contingency operations for both peak load and dominant load scenarios. Detailed specifications of the proposed test system and load flow analysis at both normal and contingency conditions for different loading conditions are presented. This test system serves as an invaluable resource for TEP studies.more » « less
An official website of the United States government