Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract We have experimentally investigated the collisionless shock acceleration of ions via the interaction of a relativistic intensity (3 × 1019W/cm2), 1.053 µm wavelength laser pulse with an underdense plasma. This plasma is formed through the use of a novel cluster jet design that allows for control of the plasma peak density and front scale length without the use of additional plasma-forming laser pulses. When the front density scale length of the target plasma is less than 60 µm, the laser pulse (1 J, 400 fs) is capable of launching an electrostatic shock wave that accelerates a proton beam. This beam is shown to have a narrow divergence angle of 0.8°, a peak flux of 14 × 106protons/sr with an ion energy exceeding 440 keV. Particle-in-cell simulations indicate this narrow ion beam is produced by converging shocks generated via filamentation of the laser pulse in high-density (near critical) plasma.more » « less
-
We have designed a new filter pack array to measure angular variations in x-ray spectra during a single shot. The filter pack was composed of repeating identical columns of aluminum and copper filters of varying thicknesses. These columns were located at different positions to measure the spectrum at each corresponding angle. This array was utilized in an experiment to measure the energy evolution of betatron x rays in a laser wakefield accelerator by curving the wakefield with a transverse density gradient, streaking the x rays across the array in front of an x-ray charge-coupled device (CCD) camera. After subtracting the background and “flattening” the image to remove spatial nonuniformities, a critical energy was calculated for each position that produced the best agreement with the measured signal. There was a clear change in critical energy with angle, shedding light on the dynamics of the electrons that traveled through the accelerator. These angles correspond to distinct emission times, covering a timescale of tens of picoseconds. The filter pack was capable of recovering these angular details without the impact of errors introduced by shot-to-shot variability.more » « less
An official website of the United States government
