Search for: All records

Creators/Authors contains: "Hu, Han"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Abstract: The ned3-019-BoilingHysteresis10kPa dataset contains five extended-heating saturated pool-boiling experiments on a flat copper surface at approximately 10 kPa and 60 W. Unlike the 30 standard tests, in which the heater was turned off shortly after CHF detection, these experiments intentionally prolonged heating after CHF to produce progressively higher post-CHF maximum surface temperatures, from approximately 75.6 to 250.1 °C. Each case includes native and processed thermal and pressure measurements, reconstructed heat-flux and surface-temperature histories, high-speed side-view video, hydrophone signals, acoustic-emission data, synchronization metadata, and derived plots. The dataset was developed to examine how post-CHF thermal history affects the return to nucleate boiling and boiling hysteresis, and serves as an external protocol-validation dataset rather than an independent set of fitting cases. This dataset is the five-case protocol-perturbation dataset used to test the boiling-hysteresis correlation in: *Pressure-Adjusted Post-CHF Apparent Base-Wall Superheat Correlates with Boiling Hysteresis in Subatmospheric Pool Boiling.* The dataset has DOI [10.5281/zenodo.22235808](https://doi.org/10.5281/zenodo.22235808) and is released under the [Creative Commons Attribution 4.0 International license](https://creativecommons.org/licenses/by/4.0/). The companion 30-case standard dataset is stored separately in `ned3-013_SubatmosphericBoiling`. The standard cases use one transient for each of three copper surfaces and ten nominal pressures. The present five cases use flat copper at approximately 10 kPa and intentionally extend the heating period after the CHF indication to produce different post-CHF maximum wall temperatures. They were excluded from fitting and used only as withheld protocol-validation cases. ## Cases and experimental design | Directory | Case identifier in raw/plot filenames | Nominal condition | Measured maximum surface temperature | |---|---|---|---:| | `1-Tmax_at_CHF` | `Boiling-420` | baseline; approximately 10 kPa; 60 W | 75.6 degC | | `2_Tmax_100C` | `Boiling-421` | approximately 100 degC target; approximately 10 kPa; 60 W | 101.7 degC | | `3_Tmax_150C` | `Boiling-422` | approximately 150 degC target; approximately 10 kPa; 60 W | 150.5 degC | | `4_Tmax_200C` | `Boiling-423` | approximately 200 degC target; approximately 10 kPa; 60 W | 198.7 degC | | `5_Tmax_250C` | `Boiling-424` | approximately 250 degC target; approximately 10 kPa; 60 W | 250.1 degC | The temperatures in the last column are derived values read from the retained processed summaries. The target temperature and the measured maximum temperature are not identical for every case. Use the measured value for quantitative analysis. 
    more » « less
  2. Abstract: This dataset contains 30 transient saturated pool-boiling experiments with deionized water on flat copper, straight-microchannel copper, and square-micropillar copper surfaces at nominal vapor-space pressures of 10, 20, 30, 40, 50, 60, 70, 80, 90, and 100 kPa. One transient is provided for each surface-pressure combination. In each standard test, a single electrical-heating step was applied until a CHF-related thermal excursion was identified, after which the heater was turned off and the cooling/recovery response was recorded. The archive includes native thermocouple and pressure records, processed thermal histories, reconstructed surface temperature, heat flux, wall superheat, heat-transfer coefficient, selected boiling-event fields, side-view high-speed videos, NumPy data archives, and selected image-derived BubbleID quantities. The data support analysis of CHF, post-CHF recovery, boiling hysteresis, thermal history, pressure effects, and surface-structure effects. The boiling-hysteresis ratio used in the companion manuscript is $$H=q''_{NBR}/q''_{CHF}$$, where NBR denotes the sustained return to the nucleate-boiling branch. Reconstructed thermal quantities and event labels are derived outputs, while projected vapor fraction and bubble counts are side-view image metrics rather than volumetric void fraction or wall dry-area measurements. The dataset is not a replicated performance database and should be analyzed with condition-aware methods because pressure sequence, surface history, and run order were not fully randomized. The companion analysis and figure-generation workflow is available in BoilingLab (https://github.com/UARK-NED3/BoilingLab/tree/main/manuscripts/boiling_hysteresis_subatmospheric). 
    more » « less
  3. Abstract: Overview    BoilingBench-CV is a benchmark dataset package for evaluating computer-vision methods for two-dimensional bubble instance segmentation and per-frame bubble morphometry. It is designed to measure within-domain performance and generalization across water and HFE-7100 imaging domains. This package does not yet establish a tracking or bubble-dynamics benchmark. Per-image contours do not encode reviewed temporal bubble identities, coalescence/breakup events, or departure times. Contents - `raw/`: immutable copies of source annotated-image subsets and their original annotation formats. - `derived/`: canonical COCO-style annotations and manifests generated from the raw data. - `splits/`: immutable grouped benchmark partitions. - `metadata/`: source, rights, annotation, and quality-assurance records. - `docs/`: data-card and release notes. The source video collections are deliberately not duplicated here. The benchmark uses annotated still images; original videos remain in their source archives. Data domains The initial pool-boiling component includes FCu-H2O, PCu-H2O, PSi-HFE, and SSi-HFE annotated subsets. They form a valuable but compound domain shift: fluid, surface, image geometry, optical arrangement, and facility may differ. Water-versus-HFE results must not be interpreted as a fluid-only causal effect. Use rules 1. Preserve `raw/` unchanged. 2. Use only the supplied grouped split files for reported benchmark results. 3. Do not split frames from the same `(regime, source video/power condition)` across partitions. 4. Report performance by regime, not only a pooled score. 5. Treat annotations flagged in `metadata/annotation_qa.md` according to the    benchmark evaluator's documented ignore policy. Attribution When using the package, cite the BoilingBench-CV dataset version and the source dataset records listed in `metadata/data_sources.csv`, together with the assigned Zenodo DOI: [10.5281/zenodo.22264378](https://doi.org/10.5281/zenodo.22264378). 
    more » « less
  4. As advances in semiconductor technology drive higher power densities, thermal management is becoming increasingly crucial to maintaining the performance and reliability of devices. In recent decades, computational fluid dynamics (CFD) has been widely used for thermal management system design. However, the computational requirement of CFD makes it impractical for iterative design-optimization, which requires thousands of high-fidelity simulations. Data-driven surrogate models address the speed limitations of CFD but are often treated as black boxes whose predictions lack physical interpretability. Neural networks (NN) combined with proper orthogonal decomposition (POD) constrain the predictions to dominant modes that have the potential to align with physical features of the underlying system. The interpretability of POD-NN learned representations remains largely unexplored. This work demonstrates a POD-NN surrogate model framework to predict 2D thermal fields for a liquid-cooled dual-chip cold plate with the goal of establishing it as a trusted model for future multi-objective cold plate design optimization. The resultant model achieves a per-sample speedup over CFD that depends on batch size, ranging from approximately {10}^3\times for single-sample inference to over {10}^6\times at large batch sizes. This range supports use across both iterative design optimization and real-time digital twin or control applications. An error decomposition analysis quantifies POD truncation and NN regression error contributions across dataset sizes, identifying a POD-truncation error floor that defines the surrogate's accuracy ceiling. A Pearson correlation analysis is used to link all four POD coefficients to identifiable thermal features demonstrating that the surrogate’s predictions are physically grounded and that prediction errors can be attributed to interpretable physical modes rather than to opaque latent dimensions. Latent space mapping further demonstrates that thermal resistance varies along physically meaningful gradients. Together, these results characterize POD-NN as a fast, interpretable, and trustworthy forward model suitable for use in subsequent optimization and digital twin studies. 
    more » « less
    Free, publicly-accessible full text available June 1, 2027
  5. Free, publicly-accessible full text available June 2, 2027
  6. Abstract: Flow boiling in microchannel heat sinks is promising for next-generation electronics cooling but it implementation is limited by the associated interfacial instabilities, flow oscillations, vapor choking, and local dryout. Existing diagnostics for two-phase flows primarily rely on optical visualization and temperature/pressure measurements, which lack the capability for real-time detection of transient flow events in compact or visually inaccessible systems. This work investigates the use of acoustic emission (AE) sensing as a nonintrusive diagnostic tool for identifying phase-change events and characterizing two-phase flow behavior in a microchannel heat sink. A multimodal experimental facility integrating synchronized acoustic emission sensing, microphone measurements, thermofluidic measurements, and optical imaging was developed for flow boiling experiments under controlled heating conditions. Representative experiments comparing single-phase flow and two-phase flow conditions demonstrate that the onset of boiling produces substantial increases in AE amplitude and AE hit rate. The results suggest that acoustic sensing can provide a sensitive indicator of bubble nucleation, vapor transport, and transient interfacial dynamics in confined boiling flows. The presented framework sets a foundation for future development of physics-informed acoustic diagnostics and machine-learning-assisted monitoring of two-phase thermal management systems. TechnicalInfo: # Data from: Acoustic signatures of two-phase flows in a microchannel heat sink Dataset DOI: [10.5061/dryad.kwh70rzm3](https://doi.org/10.5061/dryad.kwh70rzm3) ## Description of the data and file structure ##### ned-012_FlowBoilingAE.zip: This file includes four folders: DataAcquisition, MicrochannelHeatSinkCAD for design files of the microchannel heat sink and test section, and test data for a representative single-phase flow case (SinglePhase-01) and a representative two-phase flow case (TwoPhase-02). ###### DataAcquisition:  This folder includes an Arduino sketch file "Flow_Loop_Data_Collection.ino" for the acquisition of temperature, flow rate, and pressure drop data from the flow tests.  ###### MicrochannelHeatSinkCAD:  This folder includes the CAD model for the straight microchannel heat sink tested in this work. * MC - test section.V1.SLDPRT file is the CAD model of the straight microchannel heat sink used in the present work. * MC - test section.V1.STEP file is the CAD model of the straight microchannel heat sink used in the present work. ###### SinglePhase-01: This folder include six files for a representative single-phase flow test:  * Acoustic_singlephase_roomtemperature_01.DTA: Source file for AE sensing, generated by MISTRAS AEWin. * Acoustic_singlephase_roomtemperature_01.txt: AE hit file generated from the source file using MISTRAS AEWin. This file reports AE hit parameters, including time of the hit (s), AE amplitude (dB), AE rise (μs), AE count (dimensionless), AE energy (pVs), and AE duration (μs).  * Heater 5V 440mA inlet set 87C Pump 8V Test 1.txt: Temperature, flow rate, and pressure drop data recorded using Arduino, including date, time, flow rate (L/min), the fluid temperatures at the inlet and outlet of the test section (°C), pressure drop (psi), and the heater temperature (°C) at a power load of 2.2 W (voltage: 5V, current: 440 mA). * Microphone.lvm: LabVIEW measurement file recording microphone data (note that this file has flaws due to data requisition - it has time gaps where no data is registered). * Video_singlephase-01.mp4: Video file for the single-phase flow test. * multimodal_analysis_singlephase_v8.m: MATLAB code to analyze and plot the acoustic data.  ###### TwoPhase-04: This folder include six files for a representative single-phase flow test:  * Acoustic_twophase_roomtemperature_04.DTA: Source file for AE sensing, generated by MISTRAS AEWin. * Acoustic_twophase_roomtemperature_04.txt: AE hit file generated from the source file using MISTRAS AEWin. This file reports AE hit parameters, including time of the hit (s), AE amplitude (dB), AE rise (μs), AE count (dimensionless), AE energy (pVs), and AE duration (μs).  * Heater 25V 1810mA inlet set 87C Pump 8V Test 4.txt: Temperature (°C) data recorded using Arduino, including date, time, flow rate (L/min), the fluid temperatures at the inlet and outlet of the test section (°C), pressure drop (psi), and the heater temperature (°C) at a power load of 45.3 W (voltage: 25V, current: 1810 mA). * Microphone_04.lvm: LabVIEW measurement file recording microphone data (note that this file has flaws due to data requisition - it has time gaps where no data is registered). * Video_twophase_04.mp4: Video file for the two-phase flow test. * multimodal_analysis_twophase_v8.m: MATLAB code to analyze and plot the acoustic data.  ## Accessibility * The source files for AE sensing (.DTA) can be opened using MISTRAS AEWin software or MistrasDTA, an open-source package on GitHub ([https://github.com/d-cogswell/MistrasDTA](https://github.com/d-cogswell/MistrasDTA)). * The LabView measurement files (.lvm) can be opened using Notepad or pandas ([https://pandas.pydata.org/](https://pandas.pydata.org/)). * The Aduino sketch file (.ino) can be opened using a standard text editor (Notepad, Sublime Text, etc.), Arduino IDE, or VS Code.  - The SolidWorks CAD files can be opened using SolidWorks or Autodesk Viewer (free: [https://viewer.autodesk.com/](https://viewer.autodesk.com/)). - The .STEP CAD files can be opened using FreeCAD ([https://www.freecad.org/](https://www.freecad.org/)) or online STEP viewers such as [https://mantle3d.com/free-online-step-and-stl-cad-file-viewer-no-downloads-needed/](https://mantle3d.com/free-online-step-and-stl-cad-file-viewer-no-downloads-needed/) and [https://imagetostl.com/view-stp-online](https://imagetostl.com/view-stp-online) 
    more » « less
  7. Abstract: Overview   This dataset supports the manuscript *BubbleID-Flow: Machine-Vision Quantification of Vapor Area Fraction in Subcooled Flow Boiling*. It contains high-speed optical images, manually annotated images, thermal workbooks, acoustic-emission (AE) records, and the fine-tuned Mask R-CNN checkpoint used in the reported analysis. The experiments used FC-72 in a rectangular flow passage that was 2.5 mm wide and 5.0 mm high. The bottom wall was electrically heated over 114.6 mm. High-speed images were acquired with a FASTCAM SA-Z at 1024 x 1024 pixels and 3000 frames/s. The manuscript reports a two-dimensional, near-wall vapor area fraction measured from the image-plane union of predicted vapor masks. It is not a volumetric vapor fraction or void fraction. Contents ```text AnnotatedImages/   130 paired BMP images and LabelMe JSON annotation files. ModelWeights/   model_final.pth                 Fine-tuned one-class Mask R-CNN checkpoint. MultimodalData/   Images/                         Raw high-speed images and camera metadata.   FlowLoopThermalData/            Thermal workbooks and derived thermal plots.   AcousticDatta/                  AE event, continuous, waveform, and plot files. Videos/   BubbleID-Flow_45V_raw_vs_segmented.mp4                                   Derived 16-second presentation video.   BubbleID-Flow_45V_raw_vs_segmented.json   Video frame-selection and inference manifest.   BubbleID-Flow_45V_raw_top_segmented_bottom.mp4                                   Derived 16-second presentation video.   BubbleID-Flow_45V_raw_top_segmented_bottom.json                                   Video frame-selection and inference manifest. ``` `AnnotatedImages` contains 130 valid LabelMe JSON files paired with 130 BMP images. The annotation labels are `bubble` and `bubble_cluster`; the BubbleID-Flow model merges both labels into one vapor-region class for union-mask vapor-area-fraction analysis. `MultimodalData/Images` contains 3,977 BMP images and 37 `.cihx` camera metadata files. `MultimodalData/FlowLoopThermalData` contains three Excel workbooks per case: `.xlsx`, `_IN_with_units.xlsx`, and `_u_with_units.xlsx`. The PNG files under `Plot Images` and the AE `Plot_Hit` and `Plot_Time` folders are derived visualizations, not primary measurement inputs. `Videos/BubbleID-Flow_45V_raw_vs_segmented.mp4` is a derived presentation output. It shows 20 uniformly sampled frames from the 45 V state of each case at 5 frames/s (16 seconds total), with a raw near-wall view and the corresponding Mask R-CNN union-mask overlay. Its JSON sidecar records the selected filenames, checkpoint checksum, ROI, score threshold, and detection cap. Case Map | Canonical case ID | Nominal mass flow | Nominal inlet subcooling | Optical image folder | Thermal folder | AE folder | | --- | ---: | ---: | --- | --- | --- | | `5gs_22C` | 5 g/s | 22 degC | `MultimodalData/Images/5gs_22C` | `MultimodalData/FlowLoopThermalData/5gs_22C` | `MultimodalData/AcousticDatta/5gs_22C` | | `10gs_22C` | 10 g/s | 22 degC | `MultimodalData/Images/10gs_22C` | `MultimodalData/FlowLoopThermalData/10gs_22C` | `MultimodalData/AcousticDatta/10gs_22C` | | `15gs_20C` | 15 g/s | 20 degC | `MultimodalData/Images/15gs_20C` | `MultimodalData/FlowLoopThermalData/15gs_20C` | `MultimodalData/AcousticDatta/15gs_22C` (archive alias) | | `25gs_20C` | 25 g/s | 20 degC | `MultimodalData/Images/25gs_20C` | `MultimodalData/FlowLoopThermalData/25gs_20C` | `MultimodalData/AcousticDatta/25gs_22C` (archive alias) | Archive naming notes - `AcousticDatta` is the current directory name in this archive. - The AE directories `15gs_22C` and `25gs_22C` are aliases only. Their contained HIT, TIME, DTA, and WFS filenames identify the canonical `15gs_20C` and `25gs_20C` cases. Use the canonical IDs in analyses and citations. - Optical folder labels such as `25_ONSET`, `55 CHF`, and `59CHF` are source acquisition labels. They are not independently validated onset or critical-heat-flux labels. Modality Details Optical images The image folders are organized as `/`. The study uses a fixed near-wall region of interest (ROI) beginning at pixel coordinate `(0, 485)` with size `1024 x 70` pixels. Spatial calibration and registration between this ROI, the heated surface, and the seven temperature locations were not available. Therefore, this archive does not support calibrated bubble-size measurements, local optical-thermal registration, or volumetric void-fraction calculation. Thermal data The thermal workbooks contain time, mass flow, voltage, electrical power, inlet subcooling, inlet/outlet temperature, pressure, and seven test-section surface-temperature streams. The manuscript derives heat flux from electrical power and the documented heated area and derives mass flux from the measured flow area. Reported standard deviations characterize temporal variability within selected windows; they are not instrument uncertainty estimates. For each canonical case, the BubbleID-Flow manuscript pipeline uses both: - `.xlsx` for thermal variables; and - `_IN_with_units.xlsx` to obtain voltage and define/match state windows. Acoustic-emission data Each AE case directory contains: - `HIT_.TXT`: event-level hit data; - `TIME_.TXT`: continuous time-domain summary data; - `Raw Data/.wfs`: raw waveform file; - `Raw Data/.DTA`: acquisition/export file; - `notes.txt`: available operator notes; and - `Plot_Hit` and `Plot_Time`: derived diagnostic figures. The optical, thermal, and AE systems do **not** have a verified common hardware trigger. The manuscript's supplementary 10 g/s AE screen uses a 25.395 s archive-start timestamp offset for descriptive state comparison only. These data do not establish optical-acoustic synchronization, causal coupling, source localization, flow-regime classification, or calibrated AE energy. Annotations and model checkpoint The model was fine-tuned on 130 manually annotated images. The published reconstruction evaluation uses a deterministic same-sequence split: every fifth sorted image is assigned to holdout, yielding 104 training images and 26 holdout images. This is not an experiment-held-out generalization test; the source-sequence proximity between training and holdout images must be considered when interpreting performance. The included checkpoint is: ```text ModelWeights/model_final.pth SHA-256: 6f60969ce876f57a78b53fc61895c99b92cb2e1b6f0e0b30f01fa301236042cd ``` 
    more » « less
  8. Abstract: BoilingBench-Multimodal Lite is a versioned, machine-learning-oriented release from the NED³ Laboratory at the University of Arkansas. It contains seven related benchmark tracks covering pool boiling, bubble-image annotation, acoustic sensing, and infrared immersion cooling. BoilingBench-1 through BoilingBench-4 contain multimodal boiling experiments; BoilingBench-5 contains human-annotated boiling images; BoilingBench-6 is a hydrophone-focused pool-boiling dataset; and BoilingBench-7 is an infrared immersion-cooling dataset. This Lite profile omits original Phantom `.cine` recordings to reduce distribution size. It retains the released raw files, processed analysis products, annotations, manifests, plots, and machine-readable exports included in the directory. The complete archive and any omission details are documented in the accompanying README and release manifest. Raw acquisition files are measurements or source observations. Heat flux, reconstructed surface temperature, synchronization records, spectra, spectrograms, event times, hysteresis metrics, and other analysis products are derived data unless explicitly identified otherwise. BoilingLab-generated heat-flux products require users to inspect thermocouple locations, geometry, calibration, material assumptions, time alignment, sign convention, and quality fields before treating them as labels. BoilingBench-3 and BoilingBench-4 use legacy MISTRAS USB AE acquisition and do not contain continuous AE waveform exports. BoilingBench-3 contains microphone data. BoilingBench-1 and BoilingBench-2 contain continuous AE waveform products where documented. Users must split examples by independent experiment/run or physical condition rather than randomly splitting adjacent temporal windows. The dataset is intended for reproducible research in heat-transfer prediction, multimodal sensing, boiling-regime and transition analysis, bubble-image analysis, acoustic heat-flux estimation, sequence regression, and cross-domain generalization. It is not a clinical, personal, or safety-certified dataset. 
    more » « less
  9. Abstract: Medium-voltage silicon carbide (SiC) power modules are central to high-power-density converters for electrified transportation, aerospace propulsion, renewable energy systems, and medium-voltage motor drives. However, the elevated heat fluxes generated by high-voltage SiC devices impose stringent thermal management requirements while system-level mass constraints increasingly motivate lightweight cooling solutions. Prior work demonstrated a multi-tier liquid cooling architecture for a 10 kV SiC MOSFET power module featuring stacked substrates and an additively manufactured metallic cooler. Building upon this platform, this work investigates a lightweight hybrid liquid cooler that replaces the aluminum manifold with a 3D-printed nylon manifold while retaining the AlSi10Mg heat transfer core. The hybrid cooler is experimentally evaluated against the original fully metallic cooler using pressure drop measurements, thermal resistance characterization, and infrared thermography. Results show that replacing the aluminum manifold with nylon reduces the cooler mass by 51% while maintaining similar hydraulic performance across the tested flow range. The thermal resistance increases moderately due to the reduced thermal conductivity of the polymer structure and reduced parasitic thermal spreading through the manifold. The results demonstrate the feasibility of hybrid polymer-metal cooling architectures for medium-voltage power electronics applications where gravimetric thermal performance is a critical design consideration, including electrified aircraft propulsion systems and mobile power converters. TechnicalInfo: # Data from: Additively manufactured lightweight hybrid multi-tier liquid cooler for 10 kV SiC MOSFET power module Dataset DOI: [10.5061/dryad.2rbnzs84t](https://doi.org/10.5061/dryad.2rbnzs84t) ## Description of the data and file structure This dataset includes the CAD models and thermal testing data of a multi-tier liquid cooler for a 10 kV SiC MOSFET power module. This dataset includes data for two prototypes, i.e., i) a fully metallic Al-AlSi~10~Mg multi-tier liquid cooler with a CNC-milled aluminum 6061-T6 manifold and a 3D-printed (DMLS) AlSi~10~Mg heat sink core, and ii) a hybrid nylon-AlSi~10~Mg multi-tier liquid cooler with a 3D-printed (SLS) carbon-filled nylon 12 (PA12) manifold and a 3D-printed (DMLS) AlSi~10~Mg heat sink core. ### Files and variables #### File: ned-011_MultiTierColdPlate.zip **Description:**  This file contains five folders, including "Cooler Design Files," "10kV Module 150W Al-AlSi10Mg Heat Sink," "10kV Module 150W Nylon-AlSi10Mg Heat Sink," "IR Videos," and "Pictures." ###### Cooler Design Files: This folder includes three subfolders, i.e., "eDrawings_CAD," "SolidWorks_CAD," and "STEP." The "eDrawings_CAD" includes the .EPRT and .EASM files of the manifold, heat sink core, and the assembly. The "SolidWorks_CAD" subfolder includes the SoildWorks version of the same files. The "STEP" folder includes the .STEP version of the manifold and the heat sink core. ###### 10kV Module 150W Al-AlSi10Mg Heat Sink: This folder includes 11 LabVIEW measurement files (.lvm) for thermal testing data of an Al-AlSi~10~Mg multi-tier liquid cooler at a power load of 150 W and flow rates of 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, and 600 mL/min. The Al-AlSi10Mg is a fully metallic heat sink with a CNC-milled aluminum manifold and a 3D-printed (DMLS) AlSi~10~Mg heat sink core.  ###### 10kV Module 150W Nylon-AlSi10Mg Heat Sink: This folder includes 11 LabVIEW measurement files (.lvm) for thermal testing data of a nylon-AlSi~10~Mg multi-tier liquid cooler at a power load of 150 W and flow rates of 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, and 600 mL/min. The nylon-AlSi10Mg is a hybrid heat sink with a 3d-printed nylon manifold and a 3D-printed (DMLS) AlSi~10~Mg heat sink core.  ###### IR Videos: This folder includes four representative IR videos (.seq) captured using a FLIR A655sc IR camera, namely,  * Al-AlSi10Mg_150W_150mLpm: Al-AlSi~10~Mg metallic liquid cooler, power load of 150 W, water flow rate of 150 mL/min * Al-AlSi10Mg_150W_550mLpm: Al-AlSi~10~Mg metallic liquid cooler, power load of 150 W, water flow rate of 550 mL/min * Nylon-AlSi10Mg_150W_150mLpm: nylon-AlSi~10~Mg hybrid liquid cooler, power load of 150 W, water flow rate of 150 mL/min * Nylon-AlSi10Mg_150W_550mLpm: nylon-AlSi~10~Mg hybrid liquid cooler, power load of 150 W, water flow rate of 550 mL/min ###### Pictures:  This folder includes photographs of the Al-AlSi~10~Mg metallic liquid cooler and nylon-AlSi~10~Mg hybrid liquid cooler, and two representative IR images. ## Accessibility The IR videos (.seq) can be opened using FLIR Thermo Studio (Starter is free: [https://www.flir.com/instruments/thermal-studio-plan-selection/](https://www.flir.com/instruments/thermal-studio-plan-selection/)) or flirpy ([https://github.com/LJMUAstroecology/flirpy](https://github.com/LJMUAstroecology/flirpy)) The LabView measurement files (.lvm) can be opened using Notepad or pandas ([https://pandas.pydata.org/](https://pandas.pydata.org/)) The SolidWorks CAD files can be opened using SolidWorks or AutoDesk Viewer (free: [https://viewer.autodesk.com/](https://viewer.autodesk.com/)) The .STEP CAD files can be opened using FreeCAD ([https://www.freecad.org/](https://www.freecad.org/)) or online STEP viewers such as [https://mantle3d.com/free-online-step-and-stl-cad-file-viewer-no-downloads-needed/](https://mantle3d.com/free-online-step-and-stl-cad-file-viewer-no-downloads-needed/) and [https://imagetostl.com/view-stp-online](https://imagetostl.com/view-stp-online) The eDrawing files can be opened using eDrawings Pro or eDrawings Viewer (Viewer is free: [https://www.edrawingsviewer.com/download-edrawings](https://www.edrawingsviewer.com/download-edrawings)) 
    more » « less