- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Chen, Dexian (1)
-
Curtius, Joachim (1)
-
Donahue, Neil M. (1)
-
Finkenzeller, Henning (1)
-
He, Xu-Cheng (1)
-
Hofbauer, Victoria (1)
-
Iyer, Siddharth (1)
-
Kirkby, Jasper (1)
-
Kulmala, Markku (1)
-
Kurtén, Theo (1)
-
Maier, Norbert (1)
-
Rissanen, Matti (1)
-
Shen, Jiali (1)
-
Simon, Mario (1)
-
Sipilä, Mikko (1)
-
Tham, Yee Jun (1)
-
Volkamer, Rainer (1)
-
Wang, Mingyi (1)
-
Worsnop, Douglas R. (1)
-
#Tyler Phillips, Kenneth E. (0)
-
- Filter by Editor
-
-
null (1)
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Measurement of iodine species and sulfuric acid using bromide chemical ionization mass spectrometersnull (Ed.)Abstract. Iodine species are important in the marine atmosphere foroxidation and new-particle formation. Understanding iodine chemistry andiodine new-particle formation requires high time resolution, highsensitivity, and simultaneous measurements of many iodine species. Here, wedescribe the application of a bromide chemical ionization mass spectrometer(Br-CIMS) to this task. During the iodine oxidation experiments in theCosmics Leaving OUtdoor Droplets (CLOUD) chamber, we have measured gas-phaseiodine species and sulfuric acid using two Br-CIMS, one coupled to aMulti-scheme chemical IONization inlet (Br-MION-CIMS) and the other to aFilter Inlet for Gasses and AEROsols inlet (Br-FIGAERO-CIMS). From offlinecalibrations and intercomparisons with other instruments, we havequantified the sensitivities of the Br-MION-CIMS to HOI, I2, andH2SO4 and obtained detection limits of 5.8 × 106,3.8 × 105, and 2.0 × 105 molec. cm−3,respectively, for a 2 min integration time. From binding energycalculations, we estimate the detection limit for HIO3 to be1.2 × 105 molec. cm−3, based on an assumption of maximumsensitivity. Detection limits in the Br-FIGAERO-CIMS are around 1 order ofmagnitude higher than those in the Br-MION-CIMS; for example, the detectionlimits for HOI and HIO3 are 3.3 × 107 and 5.1 × 106 molec. cm−3, respectively. Our comparisons of the performanceof the MION inlet and the FIGAERO inlet show that bromide chemicalionization mass spectrometers using either atmospheric pressure or reducedpressure interfaces are well-matched to measuring iodine species andsulfuric acid in marine environments.more » « less
An official website of the United States government
