  1. Abstract As the need for high-performance computing grows, data center operators have the challenge of regulating the increasing heat densities produced by current information technology equipment. Conventional air-based cooling systems are inadequate for dissipating the heat generated by high-power servers, prompting the exploration of alternative cooling techniques. The implementation of liquid cooling, particularly liquid-to-liquid cooling systems, has been identified as a potentially advantageous solution to addressing these issues. There are four distinct forms of liquid cooling technologies used in data centers. These include single-phase immersion cooling, two-phase immersion cooling, direct-to-chip liquid cooling employing single-phase microfin routed cold plates, and direct-to-chip liquid cooling employing two-phase cold plates. The coolant distribution unit (CDU) is an essential component of the liquid cooling system used in direct-to-chip liquid cooling technology. The CDU comprises a heat exchanger, circulating pumps, coolant monitoring sensors, and a programable logic controller that receives inputs and feedback from all coolant monitoring devices. The major function of the CDU is to circulate the fluid, dissipate heat, and regulate the coolant's supply temperature at a specific flowrate within the system. Alternatively, the CDU is tasked with regulating the temperature of the refrigerant supply. Defining the desired optimal efficiency level in real-world cases, in terms of percentage efficiency, would be more effective to ensure that the CDU performs at the desired level after installation. This article aims to outline several tests conducted on a CDU to evaluate its functionality and verify its proper operation. A coolant distributing unit is examined with a closed-loop cooling system. The cooling system consists of two row manifolds, eight rack manifolds, and 32 cooling loops equipped on each of the 32 Thermal test vehicles. Thermal energy may be used to power the TTVersus to a maximum of 200 KW. A suggested cleaning technique is followed to commission the CDU with the coolants at the start of the process. The tests involve operating the CDU in a variety of modes, such as pressure differential mode and flow control mode, at a range of coolant inlet temperatures that are suggested by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). An analysis is conducted on several real-time case scenarios, such as pump failure, low load operations, high load operations, and the response time of leak detection integrated into the CDU system. Accrediting liquid-to-liquid in-row coolant distribution systems is crucial to ensure the reliable and efficient functioning of high-power data centers. These advanced cooling technologies enhance data center performance, energy efficiency, and environmental sustainability in the current era of demanding computer workloads. They achieve this by effectively addressing thermal management-related challenges. 
    more » « less
    Free, publicly-accessible full text available December 1, 2026
  2. Abstract Flushing is a crucial step performed on the cooling equipment utilized in single phase liquid cooled data centers. This process eliminates closed-loop contamination for long-term reliability. However, it is crucial to remember that total coolant removal is not feasible during the draining process because residual quantities are always left behind. Fresh coolant in data centers could be contaminated in the loop with these residuals. Bioproliferation from cross-contamination of liquid-cooled data center coolants affects reliability and efficiency. Bacterial in the coolant can cause fouling, corrosion, and inadequate heat transfer. Two tests are carried out mimicking the data center scenarios to study the formation of biogrowth. In the first test, a coupon set comprising data center TCS loop wetted materials is submerged in a known concentration of cross-contaminated solution for an extended period. Microbial growth will be analyzed by sampling every thirty days. This test replicates stagnant cooling loops and data center equipment kept in storage rooms after flushing is performed. In the second test, two separate cooling loops with a microfin channeled cold plate mounted on a heater base are utilized. These loops undergo a flushing procedure with type-II DI water and Treated water. Following the flushing procedure, a fresh coolant is filled and kept circulating within the loops. Microbial growth will be analyzed by sampling every ten days. The results highlight the need for routine bio-analysis and the adoption of efficient microbial control measures in liquid-cooled data centers. 
    more » « less
    Free, publicly-accessible full text available December 1, 2026
  3. Free, publicly-accessible full text available March 9, 2027
  4. Free, publicly-accessible full text available July 1, 2027
  5. Abstract Demand is growing for the dense and high-performing IT computing capacity to support artificial intelligence, deep learning, machine learning, autonomous cars, the Internet of Things, etc. This led to an unprecedented growth in transistor density for high-end CPUs and GPUs, creating thermal design power (TDP) of even more than 700 watts for some of the NVIDIA existing GPUs. Cooling these high TDP chips with air cooling comes with a cost of the higher form factor of servers and noise produced by server fans close to the permissible limit. Direct-to-chip cold plate-based liquid cooling is highly efficient and becoming more reliable as the advancement in technology is taking place. Several components are used in the liquid-cooled data centers for the deployment of cold plate-based direct-to-chip liquid cooling like cooling loops, rack manifolds, CDUs, row manifolds, quick disconnects, flow control valves, etc. Row manifolds used in liquid cooling are used to distribute secondary coolant to the rack manifolds. Characterizing these row manifolds to understand the pressure drops and flow distribution for better data center design and energy efficiency is important. In this paper, the methodology is developed to characterize the row manifolds. Water-based coolant Propylene glycol 25% was used as the coolant for the experiments and experiments were conducted at 21 °C coolant supply temperature. Two, six-port row manifolds' P-Q curves were generated, and the value of supply pressure and the flowrate were measured at each port. The results obtained from the experiments were validated by a technique called flow network modeling (FNM). FNM technique uses the overall flow and thermal characteristics to represent the behavior of individual components. 
    more » « less
  6. Increasing demands for cloud-based computing and storage, the Internet of Things and machine learning-based applications have necessitated the use of more eficient cooling technologies. Direct-to-chip liquid cooling using cold plates has proven to be one of the most effective methods to dissipate the high heat luxes of modern high-power CPUs and graphics processing units (GPU). While the published literature has well-documented research on the thermal aspects of direct liquid cooling, a detailed account of reliability degradation is missing. The present investigation provides an in-depth experimental analysis of the accelerated degradation of copper cold plates used in high-power direct-to-chip liquid cooling in data centers. 
    more » « less
  7. Data center cooling systems have undergone a major transformation in the persistent pursuit of better performance and lower energy use. Liquid cooling systems, particularly direct-to-chip systems, have emerged as a promising solution to address the increasing heat dissipation challenges. One critical component of such systems is the filtration mechanism, responsible for safeguarding the integrity and efficiency of the cooling process. These factors are pivotal in ensuring the reliable and sustainable operation of liquid cooling systems in high-demand applications, where electronic components continually push the boundaries of heat generation. This study undertakes a thorough examination of filters of different mesh size used in direct-to-chip liquid cooling systems. The research is multifaceted, encompassing the evaluation of filter performance, pressure drop characteristics, and long-term durability. The methodology employed in this research combines testing with a coolant distribution unit and rack setup to provide a holistic perspective on filter functionality. Findings from this study shed light on the key parameters that influence filter performance. Ultimately, the results of this research promise to contribute significantly to the advancement of direct-to-chip liquid cooling systems, facilitating the continued evolution of electronics in diverse fields, such as high-performance computing, data centers, and emerging technologies. With a focus on enhancing system reliability, efficiency, and sustainability, this study seeks to provide a valuable resource for engineers and researchers in the pursuit of effective cooling solutions for cutting-edge electronic applications. 
    more » « less
  8. Abstract In recent years there has been a phenomenal development in cloud computing, networking, virtualization, and storage, which has increased the demand for high performance data centers. The demand for higher CPU (Central Processing Unit) performance and increasing Thermal Design Power (TDP) trends in the industry needs advanced methods of cooling systems that offer high heat transfer capabilities. Maintaining the CPU temperature within the specified limitation with air-cooled servers becomes a challenge after a certain TDP threshold. Among the equipments used in data centers, energy consumption of a cooling system is significantly large and is typically estimated to be over 40% of the total energy consumed. Advancements in Dual In-line Memory Modules (DIMMs) and the CPU compatibility led to overall higher server power consumption. Recent trends show DIMMs consume up to or above 20W each and each CPU can support up to 12 DIMM channels. Therefore, in a data center where high-power dense compute systems are packed together, it demands efficient cooling for the overall server components. In single-phase immersion cooling technology, electronic components or servers are typically submerged in a thermally conductive dielectric fluid allowing it to dissipate heat from all the electronics. The broader focus of this research is to investigate the heat transfer and flow behavior in a 1U air cooled spread core configuration server with heat sinks compared to cold plates attached in series in an immersion environment. Cold plates have extremely low thermal resistance compared to standard air cooled heatsinks. Generally, immersion fluids are dielectric, and fluids used in cold plates are electrically conductive which exposes several problems. In this study, we focus only on understanding the thermal and flow behavior, but it is important to address the challenges associated with it. The coolant used for cold plate is 25% Propylene Glycol water mixture and the fluid used in the tank is a commercially available synthetic dielectric fluid EC-100. A Computational Fluid Dynamics (CFD) model is built in such a way that only the CPUs are cooled using cold plates and the auxiliary electronic components are cooled by the immersion fluid. A baseline CFD model using an air-cooled server with heat sinks is compared to the immersion cold server with cold plates attached to the CPU. The server model has a compact model for cold plate representing thermal resistance and pressure drop. Results of the study discuss the impact on CPU temperatures for various fluid inlet conditions and predict the cooling capability of the integrated cold plate in immersion environment. 
    more » « less
  9. Effective cooling is crucial for high-power liquid-cooled servers to ensure optimal performance and reliability ofcomponents. Thermal characterization is necessary to ensure that the cooling system functions as intended, is energy efficient, and minimizes downtime. In this study, a proposed methodology for thermal characterization of a high-powerliquid-cooled server/TTV [server and TTVs (thermal test vehicle) are used interchangeably] is presented. The server layout includes multiple thermal test vehicle setups equipped with direct-to-chip cold plates, with two or more connected in series to form a TTV cooling loop. These cooling loops are connected in parallel to the supply and return plenums of the cooling loop manifold, which includes a chassis-level flow distribution manifold. To obtain accurate measurements, two identical server/TTV prototypes are instrumented with sensors for coolant flow rate and temperature measurements for every TTV cooling loop. Four ultrasonic flow sensors are installed in the flow verification server/TTV to measure the coolant flow rate to each TTV cooling loop. In the thermal verification server, thermistors are installed at the outlet of each GPU heater of TTV cooling loop to log temperature measurements. The amount of heat captured by the coolant in each TTV cooling loop is subsequently estimated based on the flow rates determined from the flow verification server.This methodology enables precise characterization of the thermal performance of high-power liquid-cooled servers,ensuring optimal functionality, energy efficiency, and minimized downtime. 
    more » « less
  10. Abstract Data centers are critical to the functioning of modern society as they host digital infrastructure. However, data centers can consume significant amounts of energy, and a substantial amount of this energy goes to cooling systems. Efficient thermal management of information technology equipment is therefore essential and allows the user to obtain peak performance from a system and enables higher equipment reliability. Thermal management of data center electronics is becoming more challenging due to rising power densities at the chip level. Cooling technologies like single-phase immersion cooling allow overcoming many such challenges owing to their higher thermal mass, lower fluid pumping powers, and potential component reliability enhancements. It is known that immersion cooling deployments require extremely low coolant flow rates, and, in many cases, natural convection can also be used to sufficiently dissipate the heat from the hot server components. It, therefore, becomes difficult to ascertain whether the rate of heat transfer is being dominated by forced or natural convection. This may lead to ambiguity in choosing an optimal heat sink solution and a suitable system mechanical design due to unknown flow regimes, further leading to sub-optimal system performance. Mixed convection can be used to enhance heat transfer in immersion cooling systems. The present investigation quantifies the contribution of mixed convection using numerical methods in an immersion-cooled server. An open compute server with dual CPU sockets is modeled on Ansys Icepak with varying power loads of 115W, 160W and 200W. The chosen dielectric fluid for this single-phase immersion-cooled setup is EC-100. Steady-state Computational Fluid Dynamics (CFD) simulations are conducted for forced, natural, and mixed convection heat transfer in a thermally shadowed server configuration at varying inlet flow rates. A baseline heat sink and an optimized heat sink with an increased fin thickness and reduced fin count are utilized for performance comparison. The effect of varying Reynolds number and Richardson number on the heat transfer rate from the heat sink is discussed to assess the flow regime, stability of the flow around the submerged components which depends on the geometry, orientation, fluid properties, flow rate and direction of the flow. The dimensionless numbers’ influence on heat transfer rate from a conventional air-cooled heat sink in immersion versus an immersion-optimized heat sink is also compared. The impact of server orientation on heat transfer behavior for the immersion optimized heat sink is also studied on heat transfer behavior for the immersion optimized heat sink. 
    more » « less