Search for: All records

Creators/Authors contains: "Nilson, P M"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Characterizing the temperature of materials in high-energy-density (HED) experiments is a major gap in the benchmarking of HED matter, such as matter in the deep interiors of planets and low-mass stars. Extended x-ray absorption fine structure (EXAFS) spectroscopy is one of the few techniques capable of determining temperature at HED conditions, but the inferred EXAFS temperature depends upon the atomic potential, which itself is not measured. This work compares simultaneous EXAFS and self-emission temperature measurements [S. Boccato , ], to quantify the impact of atomic potentials implicit in the EXAFS temperature analysis. Traditional EXAFS analysis employing a harmonic potential produces systematically lower temperatures than from self-emission ( ∼35% at 100 GPa and 3000 K), while a sixth-order distortion to the pair potential recovers agreement between the two measurements. These results highlight and quantify the need and complexity of distortions or anharmonic corrections to atomic potentials at HED conditions. 
    more » « less
    Free, publicly-accessible full text available September 1, 2027
  2. X-ray spectroscopy has long been a powerful diagnostic tool for hot, dilute plasmas, providing insights into plasma conditions by measuring line shifts and broadenings of atomic transitions. The technique critically depends on the accuracy of atomic physics models used to interpret spectroscopic measurements for inferring plasma properties such as free-electron density and temperature. Over the past decades, the atomic and plasma physics communities have developed robust atomic physics models to account for various processes in hot, dilute classical plasmas. While these models have been successful in that regime, their applicability becomes uncertain when interpreting x-ray spectroscopy experiments of above-solid-density plasmas. Given that finite-temperature density-functional theory (DFT) offers a more accurate description of dense plasma environments, we present the development of a DFT-based multi-band kinetic model, VERITAS, designed to improve the interpretation of x-ray spectroscopic measurements in high-density plasmas produced by laser-driven spherical implosions. This work details the VERITAS model and its application to both time-integrated and time-resolved x-ray spectra from implosion experiments on OMEGA. The advantages and limitations of the VERITAS model will also be discussed, along with potential directions for advancing x-ray spectroscopy of dense and superdense plasmas. 
    more » « less
  3. Experiments using the OMEGA EP laser system were performed to study collisionless shock acceleration of ions driven by the interaction of a relativistically intense laser pulse with underdense plasma. The energy spectrum of accelerated ions in the direction transverse to laser propagation is measured to have several narrow-band peaks which are quasi-monoenergetic with a typical energy bandwidth of 3%. In deuterium plasmas, these ions generate a significant number of fast fusion neutrons. Particle-in-cell simulations confirm that these ions were accelerated by the interaction of transverse shocks and that the appearance of quasi-monoenergetic spectral features depends on the growth of an ion-electron two-stream instability during the interaction. 
    more » « less
  4. Experiments today can compress solids near isentropically to pressures approaching 100 × 106 atmospheres; however, determining the temperature of such matter remains a major challenge. Extended x-ray absorption fine-structure (EXAFS) spectroscopy is one of the few techniques sensitive to the bulk temperature of highly compressed solid matter, and the validity of this temperature measurement relies on constraining the local ion structure from the EXAFS spectrum. At high-energy-density (HED) conditions, the local ion structure often becomes distorted, which must be accounted for during the EXAFS analysis. Described here is a technique, using a parametrized ion-distribution model to directly analyze EXAFS spectra that provides a better constraint on the local structure than traditional second- or third-order cumulant expansion techniques at HED conditions. The parametrized ion-distribution model is benchmarked by analyzing EXAFS spectra from nickel molecular-dynamics simulations at ∼100 GPa and shown to provide a 10%–20% improvement in constraining the cumulants of the true ion distribution. 
    more » « less
  5. Time-gated Sc K-shell and Ge L-shell spectra are presented from a range of characterized thermodynamic states spanning ion densities of 1019–1020cm−3 and plasma temperatures around 2000 eV. For the higher densities studied and temperatures from 1000 to 3000 eV, the Sc and Ge x-ray emission spectra are consistent with steady-state calculations from the modern atomic kinetics model SCRAM. At the lower ion densities achieved through plasma expansion, however, the model calculations require a higher plasma temperature to reproduce the observed Ge spectrum. We attribute this to ionization disequilibrium of the Sc because the ionization time scales exceed the hydrodynamic timescale when the inferred temperatures diverge. 
    more » « less
  6. null (Ed.)