- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources4
- Resource Type
-
0000000004000000
- More
- Availability
-
13
- Author / Contributor
- Filter by Author / Creator
-
-
McComb, David W (4)
-
Reifsnyder, Alexander (4)
-
Goldberger, Joshua E (2)
-
Hachtel, Jordan A (2)
-
Windl, Wolfgang (2)
-
Yu, Bowen (2)
-
Heremans, Joseph (1)
-
Irvine, Cullen T (1)
-
Khalifa, Yehia (1)
-
Lupini, Andrew R (1)
-
Moore, Curtis E (1)
-
Nawwar, Mohammed (1)
-
Song, Tianze (1)
-
Susner, Michael A (1)
-
Wang, Chenguang (1)
-
Williams, Archibald J (1)
-
Zhu, Minyue (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Reifsnyder, Alexander; Hachtel, Jordan A; Lupini, Andrew R; McComb, David W (, Microscopy and Microanalysis)Abstract Cryo-transfer stations are essential tools in the field of cryo-electron microscopy, enabling the safe transfer of frozen vitreous samples between different stages of the workflow. However, existing cryo-transfer stations are typically configured for only the two most popular sample holder geometries and are not commercially available for all electron microscopes. Additionally, they are expensive and difficult to customize, which limits their accessibility and adaptability for research laboratories. Here, we present a new modular cryo-transfer station that addresses these limitations. The station is composed entirely of 3D-printed and off the shelf parts, allowing it to be reconfigured to a fit variety of microscopes and experimental protocols. We describe the design and construction of the station and report on the results of testing the cryo-transfer station, including its ability to maintain cryogenic temperatures and transfer frozen vitreous samples as demonstrated by vibrational spectroscopy. Our findings demonstrate that the cryo-transfer station performs comparably to existing commercial models, while offering greater accessibility and customizability. The design for the station is open source to encourage other groups to replicate and build on this development. We hope that this project will increase access to cryo-transfer stations for researchers in a variety of disciplines with nonstandard equipment.more » « lessFree, publicly-accessible full text available August 6, 2025
-
Reifsnyder, Alexander; Nawwar, Mohammed; Zhu, Minyue; Hachtel, Jordan A; Heremans, Joseph; McComb, David W (, Microscopy and Microanalysis)Free, publicly-accessible full text available July 1, 2025
-
Williams, Archibald J; Reifsnyder, Alexander; Yu, Bowen; Moore, Curtis E; Susner, Michael A; Windl, Wolfgang; McComb, David W; Goldberger, Joshua E (, Journal of Materials Chemistry C)We establish the synthesis, physical properties, and highly-frustrated magnetism of Mn2In2Se5and Mn2Ga2S5van der Waals crystals.more » « less