Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Virtual switches, used for end-host networking, drop packets when the receiving application is not fast enough to consume them. This is called the slow receiver problem, and it is important because packet loss hurts tail communication latency and wastes CPU cycles, resulting in application-level performance degradation. Further, solving this problem is challenging because application throughput is highly variable over short timescales as it depends on workload, memory contention, and OS thread scheduling. This paper presents Backdraft, a new lossless virtual switch that addresses the slow receiver problem by combining three new components: (1) Dynamic Per-Flow Queuing (DPFQ) to prevent HOL blocking and provide on-demand memory usage; (2) Doorbell queues to reduce CPU overheads; (3) A new overlay network to avoid congestion spreading. We implemented Backdraft on top of BESS and conducted experiments with real applications on a 100 Gbps cluster with both DCTCP and Homa, a state-of-the-art congestion control scheme. We show that an application with Backdraft can achieve up to 20x lower tail latency at the 99th percentile.more » « less
-
This paper presents the motivation and design of MTP, a new offload-friendly message transport protocol. Existing transport protocols like TCP, MPTCP, and UDP/Quic all have key limitations when used in a network that may potentially offload computation from end-servers into NICs, switches, and other network devices. To enable important new in-network computing use cases and correct congestion control in the face of ever changing network paths and application replicas, MTP introduces a new message transport protocol design and pathlet congestion control, a new approach where end-hosts explicitly communicate messaging information to network devices and network devices explicitly communicate network path and congestion information back to end-hosts.more » « less
-
Building insulation materials can affect indoor air by (i) releasing primary volatile organic compounds (VOCs) from building enclosure cavities to the interior space, (ii) mitigating exposure to outdoor pollutants through reactive deposition (of oxidants, e.g. , ozone) or filtration (of particles) in infiltration air, and (iii) generating secondary VOCs and other gas-phase byproducts resulting from oxidant reactions. This study reports primary VOC emission fluxes, ozone (O 3 ) reaction probabilities ( γ ), and O 3 reaction byproduct yields for eight common, commercially available insulation materials. Fluxes of primary VOCs from the materials, measured in a continuous flow reactor using proton transfer reaction-time of flight-mass spectrometry, ranged from 3 (polystyrene with thermal backing) to 61 (cellulose) μmol m −2 h −1 (with total VOC mass emission rates estimated to be between ∼0.3 and ∼3.3 mg m −2 h −1 ). Major primary VOC fluxes from cellulose were tentatively identified as compounds likely associated with cellulose chemical and thermal decomposition products. Ozone-material γ ranged from ∼1 × 10 −6 to ∼30 × 10 −6 . Polystyrene with thermal backing and polyisocyanurate had the lowest γ , while cellulose and fiberglass had the highest. In the presence of O 3 , total observed volatile byproduct yields ranged from 0.25 (polystyrene) to 0.85 (recycled denim) moles of VOCs produced per mole of O 3 consumed, or equivalent to secondary fluxes that range from 0.71 (polystyrene) to 10 (recycled denim) μmol m −2 h −1 . Major emitted products in the presence of O 3 were generally different from primary emissions and were characterized by yields of aldehydes and acetone. This work provides new data that can be used to evaluate and eventually model the impact of “hidden” materials ( i.e. , those present inside wall cavities) on indoor air quality. The data may also guide building enclosure material selection, especially for buildings in areas of high outdoor O 3 .more » « less