Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
The Xenon-Argon Technology (X-ArT) Collaboration presents a study on the dynamics of pure and xenon-doped liquid argon (LAr) scintillation. Using two types of silicon photomultipliers sensitive to different wavelength ranges, we provide evidence in favor of a contribution from long-lived ( ) extreme ultraviolet (EUV) lines emitted from argon atomic states, which enhances the light yield. This component is present in both pure and xenon-doped LAr, becoming more pronounced at higher xenon concentrations, where it complements the traditional collisional energy transfer process. To explain this mechanism, we develop a comprehensive model of the Xe-doped LAr scintillation process that integrates both collisional and radiative contributions. Additionally, we investigate how xenon doping affects LAr scintillation light yield and pulse shape discrimination. Finally, we hypothesize that the EUV component may explain the emission of spurious electrons, a known challenge in light dark matter searches using noble liquids. By characterizing the scintillation dynamics in Xe-doped LAr, identifying the long-lived EUV component, and exploring the potential origin of spurious electrons, this work lays the groundwork for optimizing detector performance and advancing the design and sensitivity of future noble liquid particle detectors. Published by the American Physical Society2025more » « less
-
We report the first search for nuclear ultra-heavy dark matter (UHDM) in a dual-phase liquid argon time projection chamber using the DarkSide-50 experiment. Unlike conventional weakly interacting massive particles (WIMPs), nuclear UHDM candidates may be composed of many dark nucleons and scatter numerous times while passing through the detector. Accounting for energy loss through the Earth's overburden, we apply selection criteria optimized for multi-scatter event topologies using the 532-day low-radiation campaign of the DarkSide-50 detector. Excluded limits on the UHDM-nucleon scattering cross section for dark nucleon masses of mχ=10,50,100,500GeV/c2 are presented.more » « lessFree, publicly-accessible full text available July 1, 2027
-
Free, publicly-accessible full text available December 1, 2026
-
Dark matter detection experiments using liquid argon rely on a precise characterization of the ionization response to nuclear recoils, especially in the keV energy range relevant for light dark matter interactions. In this work, we present a comprehensive analysis that combines new measurements from the ReD setup, part of the DarkSide experimental program, with calibration data from DarkSide-50, as well as results from the ARIS and SCENE experiments. These combined datasets enable improved constraints on atomic screening effects in the modeling of the ionization response of liquid argon to nuclear recoils. The analysis is performed within the Thomas-Imel recombination framework adopted in previous DarkSide studies, and is here further constrained by the inclusion of ReD data, which allow the screening function to be determined from calibration measurements. By including the updated ionization model into the DarkSide-50 analysis framework, we obtain stronger exclusion limits on low-mass weakly interacting massive particle (WIMP) interactions, setting new world-leading constraints in the WIMP mass range. Finally, we recast the sensitivity projections for the upcoming DarkSide-20k detector, demonstrating a significantly enhanced discovery potential for low-mass dark matter candidates.more » « lessFree, publicly-accessible full text available June 1, 2027
-
The dark matter interpretation of the DAMA/LIBRA annual modulation signal represents a long-standing open question in astroparticle physics. The SABRE experiment aims to test such claim, bringing the same detection technique to an unprecedented sensitivity. Based on ultra-low background NaI(Tl) scintillating crystals like DAMA, SABRE features a liquid scintillator Veto system, surrounding the main target, and it will deploy twin detectors: one in the Northern hemisphere at Laboratori Nazionali del Gran Sasso (LNGS), Italy and the other in the Stawell Underground Physics Laboratory (SUPL), Australia, first laboratory of this kind in the Southern hemisphere. The first very-high-purity crystal produced by the collaboration was shipped to LNGS in 2019 for characterization. It features a potassium contamination, measured by mass spectroscopy, of the order of 4 ppb, about three times lower than DAMA/LIBRA crystals. The first phase of the SABRE experiment is a Proof-of-Principle (PoP) detector featuring one crystal and a liquid scintillator Veto, at LNGS. This contribution will present the results of the stand-alone characterization of the first SABRE high-purity crystal, as well as the status of the PoP detector, commissioned early in the summer of 2020.more » « less
-
Abstract Directional sensitivity to nuclear recoils would provide a smoking gun for a possible discovery of dark matter in the form of WIMPs (Weakly Interacting Massive Particles). A hint of directional dependence of the response of a dual-phase argon Time Projection Chamber (TPC) was found in the SCENE experiment. Given the potential importance of such a capability in the framework of dark matter searches, a new dedicated experiment, ReD (Recoil Directionality), was designed by the Global Argon Dark Matter Collaboration, in order to scrutinise this hint. A small dual-phase argon TPC was irradiated with neutrons produced by the p(7Li,7Be)n reaction using the 15 MV TANDEM accelerator of the INFN - Laboratori Nazionali del Sud, Catania, Italy, so as to produce argon nuclear recoils in the range (20 - 100) keV of interest for dark matter searches. Energy and direction of nuclear recoils are inferred by the detection of the elastically-scattered neutron by a set of scintillation detectors. Events were selected by gating of the associated7Be, which is detected by a telescope of Si detectors.more » « less
-
Abstract The DarkSide-20k dark matter direct detection experiment will employ a$${21}\,\hbox {m}^{2}$$ silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors calledTiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout.$$16$$ Tiles are further grouped intoPhoto-Detector Units(PDUs). This paper details the production of the Tiles and the Quality Assurance and Quality Control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision die attaching, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.more » « lessFree, publicly-accessible full text available November 1, 2026
-
Capone, A; De_Vincenzi, M; Morselli, A (Ed.)In the direct searches for Weakly Interacting Massive Particles (WIMPs) as Dark Matter candidates, the sensitivity of the detector to the incom- ing particle direction could provide a smoking gun signature for an interesting event. The SCENE collaboration firstly suggested the possible directional de- pendence of a dual-phase argon Time Projection Chamber through the columnar recombination effect. The Recoil Directionality project (ReD) within the Global Argon Dark Matter Collaboration aims to characterize the light and charge re- sponse of a liquid Argon dual-phase TPC to neutron-induced nuclear recoils to probe for the hint by SCENE. In this work, the directional sensitivity of the de- tector in the energy range of interest for WIMPs (20-100 keV) is investigated with a data-driven analysis involving a Machine Learning algorithm.more » « less
-
Dark matter may induce an event in an Earth-based detector, and its event rate is predicted to show an annual modulation as a result of the Earth’s orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above , the lowest threshold ever achieved in such a search. Published by the American Physical Society2024more » « less
An official website of the United States government