Consecutive oscillatory eruptions of a mixture of gas and liquid in urban stormwater systems, commonly referred to as sewer geysers, are investigated using transient three-dimensional (3D) computational fluid dynamics (CFD) models. This study provides a detailed mechanistic understanding of geyser formation under partially filled dropshaft conditions, an area not previously explored in depth. The maximum geyser eruption velocities were observed to reach 14.58 m/s under fully filled initial conditions (hw/hd = 1) and reduced to 5.17 m/s and 3.02 m/s for partially filled conditions (hw/hd = 0.5 and 0.23, respectively). The pressure gradients along the horizontal pipe drove slug formation and correlated directly with the air ingress rates and dropshaft configurations. The influence of the dropshaft diameter was also assessed, showing a 116% increase in eruption velocity when the dropshaft to horizontal pipe diameter ratio (Dd/Dt) was reduced from 1.0 to 0.5. It was found that the strength of the geyser (as represented by the eruption velocity from the top of the dropshaft) increased with an increase in the initial water depth in the dropshaft and a reduction in the dropshaft diameter. Additionally, the Kelvin–Helmholtz instability criteria were satisfied during transitions from stratified to slug flow, and they were responsible for the jump and transition of the flow during the initial rise and fallback of the water in the dropshaft. The present study shows that, under an initially lower water depth in the dropshaft, immediate spillage is not guaranteed. However, the subsequent mixing of air from the horizontal pipe generated a less dense mixture, causing a change in pressure distribution along the tunnel, which drove the entire geyser mechanism. This study underscores the critical role of the initial conditions and geometric parameters in influencing geyser dynamics, offering practical guidelines for urban drainage infrastructure.more » « less
-
The storm sewer geyser is a process where an air–water mixture violently erupts from a manhole. Despite the low hydrostatic pressure, violent eruptions can achieve a height of tens of meters above the ground. This current study experimentally investigates large-scale violent geysers using a large air pocket inserted from a pressurized air tank. The total length of the pipe system is approximately 88 m with a 0.1572 m diameter pipe. This large-scale experiment facilitates the investigation of spontaneous geyser eruptions. This study identifies the role of air–water volume ratio and coefficient of pressure (ratio of absolute initial static pressure to initial dynamic pressure) on the geyser intensity using eruption images and pressure plots. A total of 116 cases are tested, in which the volume ratio is parametrically increased from 0 to 1.1 under various operating conditions. A geyser score is defined to quantify the geyser eruption nature based on visual observations. The key findings are as follows: first, a sharp transition in geyser intensity is observed at the critical volume ratio of 0.5, and pre-transition and post-transition intensity exhibit a linear relationship with the volume ratio; and second, the critical volume ratio linearly varies with the coefficient of pressure.more » « less
-
Abstract This work investigates the siphon break phenomenon associated with pipe leakage location. The present study is divided into two parts: (1) an unsteady three-dimensional (3D) computational fluid dynamics (CFD) model is developed to simulate the pressure head (water level) and discharge in the simulated siphon using the volume-of-fluid (VOF) technique under no-leakage condition and (2) using the model developed in the first part we investigated the siphon break phenomenon associated with pipe leakage location. The calculated results of transient water level and discharge rate at the simulated siphon for the no-leakage condition were in good agreement with the experimental measurements. In addition, the velocity, pressure fields, and phase fractions in the siphon pipe were analyzed in depth. The methodology and findings presented show that leakage above the hydraulic grade line and close to the top inverted U section of the siphon pipe ultimately leads to the siphon breakage, which is not the case for a leakage below the hydraulic grade line. It is also concluded that if leakage is above the hydraulic grade line and the leakage position is far away from the upper horizontal section of the siphon pipe, it may not lead to the immediate siphon breakage as ingested air gets removed with siphoning water, allowing it further time to cause complete siphon breakage.more » « less
An official website of the United States government