- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources4
- Resource Type
-
00040
- Availability
-
31
- Author / Contributor
- Filter by Author / Creator
-
-
Bottino, B. (4)
-
Caminata, A. (4)
-
Consiglio, L. (4)
-
Galbiati, C. (4)
-
Ghiano, C. (4)
-
Giovanetti, G.K. (4)
-
Gola, A. (4)
-
Horikawa, S. (4)
-
Kochanek, I. (4)
-
Kondo, K. (4)
-
Korga, G. (4)
-
Musico, P. (4)
-
Paoloni, E. (4)
-
Paternoster, G. (4)
-
Rignanese, L.P. (4)
-
Sanfilippo, S. (4)
-
Savarese, C. (4)
-
Suvorov, Y. (4)
-
Testera, G. (4)
-
Agnes, P. (3)
-
- Filter by Editor
-
-
null (1)
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract In this work we will document the design and the performances of a SiPM-based photo-detector with a surface area of 100 cm 2 conceived to operate as a replacement for PMTs. The signals from 94 SiPMs are summed up to produce an aggregated output that exhibits in liquid nitrogen a dark count rate (DCR) lower than 100 cps over the entire surface, a signal to noise ratio better than 13, and a timing resolution better than 5.5 ns. The module feeds about 360 mW at 5 V with a dynamic range in excess of 500 photo-electrons on a 100 Ω differential line. The unit can also operate at room temperature, at the cost of an increase of DCR to 10 8 cps.more » « less
-
Elersich, A. ; Agnes, P. ; Ahmad, I. ; Albergo, S. ; Albuquerque, I.F.M. ; Alexander, T. ; Alton, A.K. ; Amaudruz, P. ; Atzori Corona, M. ; Ave, M. ; et al ( , Astroparticle Physics)Free, publicly-accessible full text available October 1, 2024
-
Agnes, P. ; Albergo, S. ; Albuquerque, I.F.M. ; Alexander, T. ; Alici, A. ; Alton, A.K. ; Amaudruz, P. ; Arcelli, S. ; Ave, M. ; Avetissov, I.Ch. ; et al ( , Journal of Cosmology and Astroparticle Physics)null (Ed.)
-
Aalseth, C.E. ; Abdelhakim, S. ; Acerbi, F. ; Agnes, P. ; Ajaj, R. ; Albuquerque, I.F.M. ; Alexander, T. ; Alici, A. ; Alton, A.K. ; Amaudruz, P. ; et al ( , Journal of Instrumentation)