skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Award ID contains: 1901845

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Polymeric foams, embedded with nano-scale conductive particles, have previously been shown to display quasi-piezoelectric (QPE) properties; i.e., they produce a voltage in response to rapid deformation. This behavior has been utilized to sense impact and vibration in foam components, such as in sports padding and vibration-isolating pads. However, a detailed characterization of the sensing behavior has not been undertaken. Furthermore, the potential for sensing quasi-static deformation in the same material has not been explored. This paper provides new insights into these self-sensing foams by characterizing voltage response vs frequency of deformation. The correlation between temperature and voltage response is also quantified. Furthermore, a new sensing functionality is observed, in the form of a piezoresistive response to quasi-static deformation. The piezoresistive characteristics are quantified for both in-plane and through-thickness resistance configurations. The new functionality greatly enhances the potential applications for the foam, for example, as insoles that can characterize ground reaction force and pressure during dynamic and/or quasi-static circumstances, or as seat cushioning that can sense pressure and impact. 
    more » « less
  2. Abstract Background To compare the performance (as determined by lower extremity kinematics) of knee exercises in healthy middle-aged and older individuals immediately after instruction and one week later. Methods This is a cross-sectional study in a laboratory setting. Nineteen healthy volunteers (age [y] 63.1 ± 8.6, mass [kg] 76.3 ± 14.7, height [m] 1.7 ± 0.1) participated in this study. High speed video and reflective markers were used to track motion during four exercises. The exercises were knee flexion, straight leg raise, and “V “in supine position, and hip abduction in side lying position. All participants received verbal and tactile cues during the training phase and the therapist observed and, if necessary, corrected the exercises. Upon return a week later the participants performed the same exercises without any further instructions. Knee and hip sagittal and rotational angles were extracted from the motion capture. A repeated measures t-test was used to compare the motions between two visits. Results Participants demonstrated more knee flexion during straight leg raise and “V in” exercises at the 2nd visit compared to the 1st visit (both p  <  0.05). During the “V out” exercise, they performed more external rotation ( p  <  0.05) while they showed more internal rotation during the “V in” exercise at the 2nd visit compared to the 1st visit. Conclusions Exercise performance declined significantly in healthy middle-aged and older individuals one week after instruction. This decline occurred despite an instructional exercise sheet being given to every participant. Other approaches designed to help individuals retain the ability to perform rehabilitative exercises correctly need to be explored. 
    more » « less
  3. In this work, a knee sleeve is presented for application in physical therapy applications relating to knee rehabilitation. The device is instrumented with sixteen piezoresistive sensors to measure knee angles during exercise, and can support at-home rehabilitation methods. The development of the device is presented. Testing was performed on eighteen subjects, and knee angles were predicted using a machine learning regressor. Subject-specific and device-specific models are analyzed and presented. Subject-specific models average root mean square errors of 7.6 and 1.8 degrees for flexion/extension and internal/external rotation, respectively. Device-specific models average root mean square errors of 12.6 and 3.5 degrees for flexion/extension and internal/external rotation, respectively. The device presented in this work proved to be a repeatable, reusable, low-cost device that can adequately model the knee’s flexion/extension and internal/external rotation angles for rehabilitation purposes. 
    more » « less
  4. null (Ed.)
  5. null (Ed.)