skip to main content


Title: Facile Stem Cell Delivery to Bone Grafts Enabled by Smart Shape Recovery and Stiffening of Degradable Synthetic Periosteal Membranes

Delivering stem/progenitor cells via a degradable synthetic membrane to devitalized allogenic tissue graft surfaces presents a promising allograft‐mediated tissue regeneration strategy. However, balancing degradability and bioactivity of the synthetic membrane with physical characteristics demanded for successful clinical translation is challenging. Here, well‐integrated composites of hydroxyapatite (HA) and amphiphilic poly(lactide‐co‐glycolide)‐b‐poly(ethylene glycol)‐b‐poly(lactide‐co‐glycolide) (PELGA) with tunable degradation rates are designed that stiffen upon hydration and exhibit excellent shape recovery ability at body temperature for efficiently delivering skeletal progenitor cells around bone grafts. Unlike conventional degradable polymers that weaken upon wetting, these amphiphilic composites stiffen upon hydration as a result of enhanced polyethylene glycol (PEG) crystallization. HA‐PELGA composite membranes support the attachment, proliferation, and osteogenesis of rat periosteum‐derived cells in vitro, as well as the facile transfer of confluent cell sheets of green fluorescent protein‐labeled bone marrow stromal cells. With efficient shape memory behaviors around physiological temperature, the composite membranes can be programmed with a permanent tubular configuration, deformed into a flat temporary shape desired for cell seeding/cell sheet transfer, and triggered to wrap around a femoral bone allograft upon 37 °C saline rinse and subsequently stiffen. These properties combined make electrospun HA‐PELGA promising smart synthetic periosteal membranes for augmenting allograft healing.

 
more » « less
NSF-PAR ID:
10038627
Author(s) / Creator(s):
 ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Advanced Functional Materials
Volume:
27
Issue:
5
ISSN:
1616-301X
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    Poly(lactide‐co‐glycolide) (PLGA) has been widely used as a tissue engineering scaffold. However, conventional PLGA scaffolds are not injectable, and do not support direct cell encapsulation, leading to poor cell distribution in 3D. Here, a method for fabricating injectable and intercrosslinkable PLGA microribbon‐based macroporous scaffolds as 3D stem cell niche is reported. PLGA is first fabricated into microribbon‐shape building blocks with tunable width using microcontact printing, then coated with fibrinogen to enhance solubility and injectability using aqueous solution. Upon mixing with thrombin, firbornogen‐coated PLGA microribbons can intercrosslink into 3D scaffolds. When subject to cyclic compression, PLGA microribbon scaffolds exhibit great shock‐absorbing capacity and return to their original shape, while conventional PLGA scaffolds exhibit permanent deformation after one cycle. Using human mesenchymal stem cells (hMSCs) as a model cell type, it is demonstrated that PLGA μRB scaffolds support homogeneous cell encapsulation, and robust cell spreading and proliferation in 3D. After 28 days of culture in osteogenic medium, hMSC‐seeded PLGA μRB scaffolds exhibit an increase in compressive modulus and robust bone formation as shown by staining of alkaline phosphatase, mineralization, and collagen. Together, the results validate PLGA μRBs as a promising injectable, macroporous, non‐hydrogel‐based scaffold for cell delivery and tissue regeneration applications.

     
    more » « less
  2. Abstract

    Hematopoietic stem and progenitor cells (HSPCs) are desirable targets for gene therapy but are notoriously difficult to target and transfect. Existing viral vector‐based delivery methods are not effective in HSPCs due to their cytotoxicity, limited HSPC uptake and lack of target specificity (tropism). Poly(lactic‐co‐glycolic acid) (PLGA) nanoparticles (NPs) are attractive, nontoxic carriers that can encapsulate various cargo and enable its controlled release. To engineer PLGA NP tropism for HSPCs, megakaryocyte (Mk) membranes, which possess HSPC‐targeting moieties, were extracted and wrapped around PLGA NPs, producing MkNPs. In vitro, fluorophore‐labeled MkNPs are internalized by HSPCs within 24 h and were selectively taken up by HSPCs versus other physiologically related cell types. Using membranes from megakaryoblastic CHRF‐288 cells containing the same HSPC‐targeting moieties as Mks, CHRF‐wrapped NPs (CHNPs) loaded with small interfering RNA facilitated efficient RNA interference upon delivery to HSPCs in vitro. HSPC targeting was conserved in vivo, as poly(ethylene glycol)–PLGA NPs wrapped in CHRF membranes specifically targeted and were taken up by murine bone marrow HSPCs following intravenous administration. These findings suggest that MkNPs and CHNPs are effective and promising vehicles for targeted cargo delivery to HSPCs.

     
    more » « less
  3. Abstract

    Clinical application of injectable, thermoresponsive hydrogels is hindered by lack of degradability and controlled drug release. To overcome these challenges, a family of thermoresponsive, ABC triblock polymer‐based hydrogels has been engineered to degrade and release drug cargo through either oxidative or hydrolytic/enzymatic mechanisms dictated by the “A” block composition. Three ABC triblock copolymers are synthesized with varying “A” blocks, including oxidation‐sensitive poly(propylene sulfide), slow hydrolytically/enzymatically degradable poly(ε‐caprolactone), and fast hydrolytically/enzymatically degradable poly(d,l‐lactide‐co‐glycolide), forming the respective formulations PPS135b‐PDMA152b‐PNIPAAM225(PDN), PCL85b‐PDMA150b‐PNIPAAM150(CDN), and PLGA60b‐PDMA148b‐PNIPAAM152(LGDN). For all three polymers, hydrophilic poly(N,N‐dimethylacrylamide) and thermally responsive poly(N‐isopropylacrylamide) comprise the “B” and “C” blocks, respectively. These copolymers form micelles in aqueous solutions at ambient temperature that can be preloaded with small molecule drugs. These solutions quickly transition into hydrogels upon heating to 37 °C, forming a supra‐assembly of physically crosslinked, drug‐loaded micelles. PDN hydrogels are selectively degraded under oxidative conditions while CDN and LGDN hydrogels are inert to oxidation but show differential rates of hydrolytic/enzymatic decomposition. All three hydrogels are cytocompatible in vitro and in vivo, and drug‐loaded hydrogels demonstrate differential release kinetics in vivo corresponding with their specific degradation mechanism. These collective data highlight the potential cell and drug delivery use of this tunable class of ABC triblock polymer thermogels.

     
    more » « less
  4. Abstract

    While highly porous biodegradable sponges have typically been used as tissue engineering scaffolds, they could be applicable in settings requiring drug delivery. Since most drug delivery devices are intentionally solid, nonporous polymers, a detailed structure–function relationship of delivery from a porous degradable sponges would allow researchers to develop such devices for either delivery alone, or in conjunction with tissue engineering. Two fabrication techniques (salt‐leaching and solvent‐quenching) were used to prepare several different variations of poly(DL‐lactide‐glycolide) and poly(caprolactone)‐co‐poly(lactide) porous sponges. Upon fabrication, an in‐depth structure–function analysis was carried out where the functions of loading capacity and release profile of cisplatin, as a model drug, were evaluated in terms of the swelling, porosity, and degradation properties of the sponges. Swelling, pore volume fraction, and the number of pores per volume were all found to be positively correlated with both the loading capacity and amount of cisplatin released after 2 hr. Knowledge of these relationships can be used to assist in the design of other porous delivery systems.

     
    more » « less
  5. null (Ed.)
    In this paper, we report on a novel biocompatible micromechanical bioreactor (actuator and sensor) designed for the in situ manipulation and characterization of live microtissues. The purpose of this study was to develop and validate an application-targeted sterile bioreactor that is accessible, inexpensive, adjustable, and easily fabricated. Our method relies on a simple polydimethylsiloxane (PDMS) molding technique for fabrication and is compatible with commonly-used laboratory equipment and materials. Our unique design includes a flexible thin membrane that allows for the transfer of an external actuation into the PDMS beam-based actuator and sensor placed inside a conventional 35 mm cell culture Petri dish. Through computational analysis followed by experimental testing, we demonstrated its functionality, accuracy, sensitivity, and tunable operating range. Through time-course testing, the actuator delivered strains of over 20% to biodegradable electrospun poly (D, L-lactide-co-glycolide) (PLGA) 85:15 non-aligned nanofibers (~91 µm thick). At the same time, the sensor was able to characterize time-course changes in Young’s modulus (down to 10–150 kPa), induced by an application of isopropyl alcohol (IPA). Furthermore, the actuator delivered strains of up to 4% to PDMS monolayers (~30 µm thick), simultaneously characterizing their elastic modulus up to ~2.2 MPa. The platform repeatedly applied dynamic (0.23 Hz) tensile stimuli to live Human Dermal Fibroblast (HDF) cells for 12 hours (h) and recorded the cellular reorientation towards two angle regimes, with averages of −58.85° and +56.02°. The device biocompatibility with live cells was demonstrated for one week, with no signs of cytotoxicity. We can conclude that our PDMS bioreactor is advantageous for low-cost tissue/cell culture micromanipulation studies involving mechanical actuation and characterization. Our device eliminates the need for an expensive experimental setup for cell micromanipulation, increasing the ease of live-cell manipulation studies by providing an affordable way of conducting high-throughput experiments without the need to open the Petri dish, reducing manual handling, cross-contamination, supplies, and costs. The device design, material, and methods allow the user to define the operational range based on their targeted samples/application. 
    more » « less