skip to main content


Title: Electrophoretic deposition of MgO nanoparticles imparts antibacterial properties to poly‐L‐lactic acid for orthopedic applications
Abstract

Bacterial infection of implanted biomaterials is a serious problem that increases health care costs and negatively affects a considerable fraction of orthopedic procedures. In this field, magnesium oxide nanoparticles (MgO NPs) have emerged as a promising material to combat bacterial infection while maintaining or improving bone cell functions. Here, MgO NPs were electrophoretically deposited onto poly‐L‐lactic acid (PLLA) sheets to achieve a coating of highly exposed MgO NPs that directly influenced cell‐substrate interactions at short time scales. Samples were characterized for their surface chemistry, crystal structure, roughness, wettability, degradation characteristics, and their ability to support the growth of human fibroblasts and osteoblasts, as well as their resistance to colonization byStaphylococcus aureus,Staphylococcus epidermidis, andPseudomonas aeruginosa. In general, increasing the applied voltage during deposition increased the surface coverage of the coating and significantly decreased the colonization of all three bacterial strains (up to a 90% reduction). Furthermore,S. aureuscells that did attach onto substrates prepared at high voltages exhibited trademark signs of membrane damage and cell death. Importantly, MTS cell viability assays indicated that osteoblast adhesion increased with increasing deposition voltage, while fibroblast adhesion exhibited the opposite trend. Thus, although requiring more studies, this research provides the first evidence that MgO NP coatings prepared at relatively high voltages (120–150 V) may have the ability to resist bacterial colonization, promote bone cell attachment, and curb fibrous capsule formation. Therefore, it is recommended that this technology be further investigated and developed for numerous orthopedic applications. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 3136–3147, 2017.

 
more » « less
NSF-PAR ID:
10039042
Author(s) / Creator(s):
 ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Journal of Biomedical Materials Research Part A
Volume:
105
Issue:
11
ISSN:
1549-3296
Page Range / eLocation ID:
p. 3136-3147
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    INTRODUCTION: Orthopedic implants are important therapeutic devices for the management of a wide range of orthopedic conditions. However, bacterial infections of orthopedic implants remain a major problem, and not an uncommon one, leading to an increased rate of osteomyelitis, sepsis, implant failure and dysfunction, etc. Treating these infections is more challenging as the causative organism protects itself by the production of a biofilm over the implant’s surface (1). Infections start by the adhesion and colonization of pathogenic bacteria such as Staphylococcus aureus (SA), Staphylococcus epidermidis (SE), Escherichia coli (E. coli), Methicillin-Resistant Staphylococcus aureus (MRSA), and Multi-Drug Resistant Escherichia coli (MDR E. coli) on the implant’s surfaces. Specifically, Staphylococcus comprises up to two-thirds of all pathogens involved in orthopedic implant infections (2). However, bacterial surface adhesion is a complex process influenced by several factors such as chemical composition, hydrophobicity, magnetization, surface charge, and surface roughness of the implant (3). Considering the intimate association between bacteria and the implant surface, we measured the effect of stainless-steel surface properties on bacterial surface attachment and subsequent formation of biofilms controlling above mentioned factors. METHODS: The prominent bacteria responsible for orthopedic implant infections (SA, SE, E. coli, MRSA, and MDR E. coli) were used in this study. We were able to control the grain size of medical grade 304 and 316L stainless steel without altering their chemical composition (grain size range= 20μm-200nm) (4). Grain size control affected the nano-topography of the material surfaces which was measured by an Atomic Force Microscope (AFM). Grain sizes, such as 0.2, 0.5, 1, 2, 3, 9, and 10 μm, were used both polished and non-polished. All the stainless-steel samples were cleaned by treating with acetone and ethanol under sonication. Triplicates of all polished and non-polished samples with different grain sizes were subjected to magnetization of DM, 0.1T, 0.5T, and 1T, before seeding them with the bacteria. Controls were used in the form of untreated samples. Bacterial were grown in Tryptic Soy Broth (TSB). An actively growing bacterial suspension was seeded onto the stainless-steel discs into 24-well micro-titer plates and kept for incubation. After 24 hours of incubation, the stainless-steel discs were washed with Phosphate Buffer Saline (PBS) to remove the plankton bacteria and allow the sessile bacteria in the biofilm to remain. The degree of development of the bacterial biofilms on the stainless-steel discs were measured using spectrophotometric analysis. For this, the bacterial biofilm was removed from the stainless steel by sonication. The formation of biofilms was also determined by performing a biofilm staining method using Safranin. RESULTS SECTION: AFM results revealed a slight decrease in roughness by decreasing the grain size of the material. Moreover, the samples were segregated into two categories of polished and non-polished samples, in which polishing decreased roughness significantly. After careful analysis we found out that polished surfaces showed a higher degree for biofilm formation in comparison to the non-polished ones. We also observed that bacteria showed a higher rate for biofilm formation for the demagnetized samples, whereas 0.5T magnetization showed the least amount of biofilm formation. After 0.5T, there was no significant change in the rate of biofilm formation on the stainless-steel samples. Altogether, stainless steel samples containing 0.5 μm and less grainsize, and magnetized with 0.5 tesla and stronger magnets demonstrated the least degree of biofilm formation. DISCUSSION: In summary, the results demonstrate that controlling the grain size of medical grade stainless steel can control and mitigate bacterial responses on, and thus possibly infections of, orthopedic implants or other implantable devices. The research was funded by Komatsuseiki Kosakusho Co., Ltd (KSJ: Japan) SIGNIFICANCE/CLINICAL RELEVANCE: Orthopedic implants that more than 70% of them are made of metals (i.e., stainless steel, titanium, and cobalt-chromium alloys) are failing through loosening and breakage due to their limited mechanical properties. On the other hand, the risk of infection for these implants and its financial burden on our society is undeniable. We have seen that our uniformly nanograined stainless steel shows improved mechanical properties (i.e., higher stiffness, hardness, fatigue) as compared to conventional stainless steel along with the reduction of biofilm formation on its surface. These promising results made us to peruse the development of nanograined titanium and cobalt-chromium alloys for resolving the complications of orthopedic implants. 
    more » « less
  2. Statement of Purpose: Orthopedic implants are important therapeutic devices for the management of a wide range of orthopedic conditions. However, bacterial infections of orthopedic implants remain a major problem, and not an uncommon one, leading to an increased rate of osteomyelitis, sepsis, implant failure and dysfunction, etc. Treating these infections is more challenging as the causative organism protects itself by the production of a biofilm over the implant’s surface (1). Infections start by the adhesion and colonization of pathogenic bacteria such as Staphylococcus aureus (SA), Staphylococcus epidermidis (SE), Escherichia coli (E. coli), Methicillin-Resistant Staphylococcus aureus (MRSA), and Multi-Drug Resistant Escherichia coli (MDR E. coli) on the implant’s surfaces. Specifically, Staphylococcus comprises up to two-thirds of all pathogens involved in orthopedic implant infections (2). However, bacterial surface adhesion is a complex process influenced by several factors such as chemical composition, hydrophobicity, magnetization, surface charge, and surface roughness of the implant (3). Considering the intimate association between bacteria and the implant surface, we measured the effect of stainless-steel surface properties on bacterial surface attachment and subsequent formation of biofilms controlling above mentioned factors. Method: The prominent bacteria responsible for orthopedic implant infections (SA, SE, E. coli, MRSA, and MDR E. coli) were used in this study. We were able to control the grain size of medical grade 304 and 316L stainless steel without altering their chemical composition (grain size range= 20μm-200nm) (4). Grain size control affected the nano-topography of the material surfaces which was measured by an Atomic Force Microscope (AFM). Grain sizes, such as 0.2, 0.5, 1, 2, 3, 9, and 10 μm, were used both polished and non-polished. All the stainless-steel samples were cleaned by treating with acetone and ethanol under sonication. Triplicates of all polished and non-polished samples with different grain sizes were subjected to magnetization of DM, 0.1T, 0.5T, and 1T, before seeding them with the bacteria. Controls were used in the form of untreated samples. Bacterial were grown in Tryptic Soy Broth (TSB). An actively growing bacterial suspension was seeded onto the stainless-steel discs into 24-well micro-titer plates and kept for incubation. After 24 hours of incubation, the stainless-steel discs were washed with Phosphate Buffer Saline (PBS) to remove the plankton bacteria and allow the sessile bacteria in the biofilm to remain. The degree of development of the bacterial biofilms on the stainless-steel discs were measured using spectrophotometric analysis. For this, the bacterial biofilm was removed from the stainless steel by sonication. The formation of biofilms was also determined by performing a biofilm staining method using Safranin. Results: AFM results revealed a slight decrease in roughness by decreasing the grain size of the material. Moreover, the samples were segregated into two categories of polished and non-polished samples, in which polishing decreased roughness significantly. After careful analysis we found out that polished surfaces showed a higher degree for biofilm formation in comparison to the non-polished ones. We also observed that bacteria showed a higher rate for biofilm formation for the demagnetized samples, whereas 0.5T magnetization showed the least amount of biofilm formation. After 0.5T, there was no significant change in the rate of biofilm formation on the stainless-steel samples. Altogether, stainless steel samples containing 0.5 μm and less grainsize, and magnetized with 0.5 tesla and stronger magnets demonstrated the least degree of biofilm formation. Conclusion: In summary, the results demonstrate that controlling the grain size of medical grade stainless steel can control and mitigate bacterial responses on, and thus possibly infections of, orthopedic implants or other implantable devices. The research was funded by Komatsuseiki Kosakusho Co., Ltd (KSJ: Japan) 
    more » « less
  3. null (Ed.)
    Musculoskeletal conditions such as low back pain, arthritis and other diseases of the joints affect millions of people around the world and are one the leading causes of disability (1). These diseases often require surgery, including total joint replacement in cases of deterioration of the natural joint (2). Serious concern regarding such procedure is the bacteria adhesion and proliferate on the surfaces of these orthopedic implants. Moreover, bacteria have shown the ability to generate resistance against drugs that once could kill them, hence, being more difficult or even impossible to eliminate them. These pathogens are the principal causative agents of two major types of infection in bone: septic arthritis and osteomyelitis, which involve the inflammatory destruction of joint and bone (3). Therefore, there is an unmet need to generate materials capable of showing reduced bacterial adhesion as well as bactericidal effect in order to avoid further health complications. nanoSUS Bio-Tech was founded based on a collaboration between Komatsuseiki Kosakusho Co., Ltd (KSJ:Japan) and Northeastern University (NEU) in 2019. KSJ has been developing ultra-fine-grained stainless steel since 2002 (4, 5). Using this technology, we are able to control the grain size without any changes in the chemical composition of commercially available FDA approved stainless steel. On the other hand, Thomas J. Webster’s lab has achieved the ability to decrease bacteria adhesion and growth with and without the use of antibiotics, for nanostructured surfaces. As an outcome of this collaboration, we were able to manufacture high strength ultra-fine-grained stainless steel with antimicrobial surface. The global orthopedic implants market was estimated at $45.90 billion in 2017 and is expected to reach at $66.63 billion by 2025, registering a CAGR of 4.7% from 2018 to 2025 (6), due to the growing demand by increasing geriatric population, rising incidence of spine illness and technological advancements in this field. Based on geography, North America accounted for nearly half of the total market revenue in 2017 and is anticipated to retain its top status till 2025. At the same time, the Asia-Pacific region would cite the fastest CAGR of 6.4% throughout the study period. Based on current market trends, companies such as Zimmer, Stryker, S&N, Depuy, J&J, and Medtronic are our target customers. Currently, we are expanding our network in the US by becoming member of Center for Disruptive Musculoskeletal Innovations (CDMI). Moreover, this project is funded through CDMI NSF program that will aid to expand the collaboration between KSJ and NEU. The company will be established by financing from KSJ, in Boston, MA. It will manage the collaborations between academia, marketing consultants and lawyers in the US, and directors and researchers in Japan and the US. We are expecting to start our sales from the beginning of 2021. 
    more » « less
  4. Abstract

    This research provides a new method for preparing nanoparticle‐coated viscose nonwoven fabrics, which has broad application prospects in the functional fiber industry. In this work amino‐terminated hyperbranched polymer (HBP)‐capped Selenium nanoparticles (Se NPs) were synthesized for coating viscose nonwoven fabric (VNF) via impregnation method to produce a controllable and uniform Se NPs coating on the viscose fiber surface. The prepared Se NPs and the treated VNF were characterized by the transmission electron microscope (TEM), x‐ray diffraction (XRD), x‐ray photoelectron spectroscopy (XPS), field emission scanning electron microcopy (FE‐SEM), and antibacterial measurement. The results indicate that the Se NPs were spherical shaped with an average size of 50 nm. FESEM, XRD, and XPS characterizations demonstrated that Se NPs can adsorbed and distributed uniformly on the fiber surface. Se NPs‐coated VNF showed above 99.9% bacterial reduction ofStaphylococcus aureusandEscherichia coliwhile the Se element content on VNF was about 2.92 mg/g.

     
    more » « less
  5. Three-dimensional (3D) printing is implemented for surface modification of titanium alloy substrates with multilayered biofunctional polymeric coatings. Poly(lactic-coglycolic) acid (PLGA) and polycaprolactone (PCL) polymers were embedded with amorphous calcium phosphate (ACP) and vancomycin (VA) therapeutic agents to promote osseointegration and antibacterial activity, respectively. PCL coatings revealed a uniform deposition pattern of the ACP-laden formulation and enhanced cell adhesion on the titanium alloy substrates as compared to the PLGA coatings. Scanning electron microscopy and Fourier-transform infrared spectroscopy confirmed a nanocomposite structure of ACP particles showing strong binding with the polymers. Cell viability data showed comparable MC3T3 osteoblast proliferation on polymeric coatings as equivalent to positive controls. In vitro live/dead assessment indicated higher cell attachments for 10 layers (burst release of ACP) as compared to 20 layers (steady release) for PCL coatings. The PCL coatings loaded with the antibacterial drug VA displayed a tunable release kinetics profile based on the multilayered design and drug content of the coatings. Moreover, the concentration of active VA released from the coatings was above the minimum inhibitory concentration and minimum bactericidal concentration, demonstrating its effectiveness against Staphylococcus aureus bacterial strain. This research provides a basis for developing antibacterial biocompatible coatings to promote osseointegration of orthopedic implants. 
    more » « less