Title: Flow Analysis and Linearization of Rectangular Butterfly Valve Flow Control Device for Liquid Cooling
One of the key areas in which electronic cooling research has been focusing on, is addressing the issue of non-uniform at package level. This challenge has incited the use of numerous temperature sensing mechanisms for dynamic cooling of electronic components. What dynamic liquid cooling effectively does is, use feedback from sensors as inputs for the pumps, supplying more amounts of fluid to parts of the electronics that is warmer while supplying minimal fluid to the parts of the electronics that are relatively cooler. A novel approach to address uneven heating in a liquid cooled system is the use of a temperature sensing flow control device that can control flow rate based on temperature. The necessity of numerous temperature and pressure sensors, a suitable control system and the maintenance and reliability issues that they present, can be significantly minimized with the use of a self sensing and controlling flow control device. This paper looks at the flow analysis of a self-regulating flow control device (FCD) designed for electronic module for data center application. An axially rotating butterfly valve is used to regulate the flow rate of FCD. Linearization of the flow with respect to damper angle is studied by modifying the dimensional ratios of the rectangular cross section of the FCD. Pressure drop, and flow rate characterization is done for the FCD.  more » « less
Award ID(s):
1738811
PAR ID:
10065924
Author(s) / Creator(s):
; ; ; ;
Date Published:
Journal Name:
2018 17th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Abstract Data centers are a large group of networked servers used by organizations for computational and storage purposes. In 2014, data centers consumed an estimated 70 billion kWh in the United States alone. It is incumbent on thermal engineers to develop efficient methods in order to minimize the expenditure at least toward cooling considering the limited available power resources. One of the key areas where electronic cooling research has been focusing, is addressing the issue of nonuniform power distribution at the rack, server and even at package levels. Nonuniform heating at the chip level creates hotspots and temperature gradients across the chip which in turn significantly increases the cost of cooling, as cooling cost is a function of the maximum junction temperature. This challenge has increased the use of temperature sensing mechanisms to help in finding ways to mitigate the gradients. A very effective way to conserve pumping power and address hotspots on the single or multichip modules is by targeted delivery of liquid coolant. One way to enable such targeted delivery of coolant is by using dynamic cold plates coupled with self-regulating flow control device that can control flow rate based on temperature. This novel technology will have more effective implementation coupled with a good control strategy. This paper addresses the development and testing of such control strategy with minimal sensors along with less latency and optimization of the same. 
    more » « less
  2. Abstract Transistor density trends till recently have been following Moore's law, doubling every generation resulting in increased power density. The computational performance gains with the breakdown of Moore's law were achieved by using multicore processors, leading to nonuniform power distribution and localized high temperatures making thermal management even more challenging. Cold plate-based liquid cooling has proven to be one of the most efficient technologies in overcoming these thermal management issues. Traditional liquid-cooled data center deployments provide a constant flow rate to servers irrespective of the workload, leading to excessive consumption of coolant pumping power. Therefore, a further enhancement in the efficiency of implementation of liquid cooling in data centers is possible. The present investigation proposes the implementation of dynamic cooling using an active flow control device to regulate the coolant flow rates at the server level. This device can aid in pumping power savings by controlling the flow rates based on server utilization. The flow control device design contains a V-cut ball valve connected to a microservo motor used for varying the device valve angle. The valve position was varied to change the flow rate through the valve by servomotor actuation based on predecided rotational angles. The device operation was characterized by quantifying the flow rates and pressure drop across the device by changing the valve position using both computational fluid dynamics and experiments. The proposed flow control device was able to vary the flow rate between 0.09 lpm and 4 lpm at different valve positions. 
    more » « less
  3. Abstract The increasing demand for high-performance computing in applications such as the Internet of Things, Deep Learning, Big data for crypto-mining, virtual reality, healthcare research on genomic sequencing, cancer treatment, etc. have led to the growth of hyperscale data centers. To meet the cooling energy demands of HPC datacenters efficient cooling technologies must be adopted. Traditional air cooling, direct-to-chip liquid cooling, and immersion are some of those methods. Among all, Liquid cooling is superior compared to various air-cooling methods in terms of energy consumption. Direct on-chip cooling using cold plate technology is one such method used in removing heat from high-power electronic components such as CPUs and GPUs in a broader sense. Over the years Thermal Design Power (TDP) is rapidly increasing and will continue to increase in the coming years for not only CPUs and GPUs but also associated electronic components like DRAMs, Platform Control Hub (PCH), and other I/O chipsets on a typical server board. Therefore, unlike air hybrid cooling which uses liquid for cold plates and air as the secondary medium of cooling the associated electronics, we foresee using immersion-based fluids to cool the rest of the electronics in the server. The broader focus of this research is to study the effects of adopting immersion cooling, with integrated cold plates for high-performance systems. Although there are several other factors involved in the study, the focus of this paper will be the optimization of cold plate microchannels for immersion-based fluids in an immersion-cooled environment. Since immersion fluids are dielectric and the fluids used in cold plates are conductive, it exposes us to a major risk of leakage into the tank and short-circuiting the electronics. Therefore, we propose using the immersed fluid to pump into the cold plate. However, it leads to a suspicion of poor thermal performance and associated pumping power due to the difference in viscosity and other fluid properties. To address the thermal and flow performance, the objective is to optimize the cold plate microchannel fin parameters based on thermal and flow performance by evaluating thermal resistance and pressure drop across the cold plate. The detailed CFD model and optimization of the cold plate were done using Ansys Icepak and Ansys OptiSLang respectively. 
    more » « less
  4. Miniaturization and high heat flux of power electronic devices have posed a colossal challenge for adequate thermal management. Conventional air-cooling solutions are inadequate for high-performance electronics. Liquid cooling is an alternative solution thanks to the higher specific heat and latent heat associated with the coolants. Liquid-cooled cold plates are typically manufactured by different approaches such as: skived, forged, extrusion, electrical discharge machining. When researchers are facing challenges at creating complex geometries in small spaces, 3D-printing can be a solution. In this paper, a 3D-printed cold plate was designed and characterized with water coolant. The printed metal fin structures were strong enough to undergo pressure from the fluid flow even at high flow rates and small fin structures. A copper block with top surface area of 1 inch by 1 inch was used to mimic a computer chip. Experimental data has good match with a simulation model which was built using commercial software 6SigmaET. Effects of geometry parameters and operating parameters were investigated. Fin diameter was varied from 0.3 mm to 0.5 mm and fin height was maintained at 2 mm. A special manifold was designed to maximize the surface contact area between coolant and metal surface and therefore minimize thermal resistance. The flow rate was varied from 0.75 L/min to 2 L/min and coolant inlet temperature was varied from 25 to 48 oC. It was observed that for the coolant inlet temperature 25 oC and aluminum cold plate, the junction temperature was kept below 63.2 oC at input power 350 W and pressure drop did not exceed 23 Kpa. Effects of metal materials used in 3D-printing on the thermal performance of the cold plate were also studied in detail. 
    more » « less
  5. Microfluidic devices are defined by the application of fluid flow to micron-scale features. Inherent to most experiments involving microfluidic devices is the need to precisely and reproducibly control fluid flow at the microliter scale, often through multiple inlet ports on a single device. While the number of fluid channels per device varies, perfusing multiple inputs requires either the use of multiple flow controllers (often syringe or peristaltic pumps) or the ability to evenly divide fluid across outlets. Towards the latter approach, while a handful of commercial systems exist for splitting fluid flow, these set-ups require significant financial investment, multiple flow control and sensing components, and restrict the user to a predetermined perfusion control system. Simple in-line splitting devices, such a manifolds or T junctions, fail to achieve flow splitting at low flow rates often used in microfluidic systems. To increase capabilities for flow-controlled experiments, we performed experimental analyses of the physical considerations governing even flow splitting under low flow, leading to the design of a microdevice (µ-Split) that can be directly inserted into existing microfluidic set-ups. The µ-Split allows for reproducible, even flow splitting from 10 uL/min to > 2.5 mL/min. By testing multiple device geometries in combination with multiphysics simulations, we identified the design and fabrication features underlying the splitting precision achieved by the µ-Split. Overall, this work provides a useful tool to simplify microfluidic experiments that require evenly divided flow streams, while minimizing the overall device footprint. 
    more » « less