Title: Sub-Hertz Resonance by Weak Measurement
Here we propose and demonstrate a novel weak-measurement-enhanced spectroscopy technique, which allows narrowing the resonance to 0.1 Hz and high sensitivity 7 fT/Hz^1/2 near DC in a room-temperature atomic-vapor cell, by designing a non-Hermitian Hamiltonian.  more » « less
Award ID(s):
1741693 1806519
PAR ID:
10119041
Author(s) / Creator(s):
; ; ; ; ; ;
Date Published:
Journal Name:
Nonlinear Optics (NLO) OSA Technical Digest (Optical Society of America, 2019)
Page Range / eLocation ID:
NTh2A.1
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. The experimental results of LEAP (Liquefaction Experiments and Analysis Projects) centrifuge test replicas of a saturated sloping deposit are used to assess the sensitivity of soil accelerations to variability in input motion and soil deposition. A difference metric is used to quantify the dissimilarities between recorded acceleration time histories. This metric is uniquely decomposed in terms of four difference component measures associated with phase, frequency shift, amplitude at 1 Hz, and amplitude of frequency components higher than 2 Hz (2 + Hz). The sensitivity of the deposit response accelerations to differences in input motion amplitude at 1 Hz and 2 + Hz and cone penetration resistance (used as a measure reflecting soil deposition and initial grain packing condition) was obtained using a Gaussian process-based kriging. These accelerations were found to be more sensitive to variations in cone penetration resistance values than to the amplitude of the input motion 1 Hz and 2 + Hz (frequency) components. The sensitivity functions associated with this resistance parameter were found to be substantially nonlinear. 
    more » « less
  2. This flux-tower observational campaign occurred in Utqiagvik, AK. A 12-m tower was installed in February 2022 to collect turbulence data at a total of five heights (0.5 m, 1.5 m, 2.5 m, 3.5 m, and 7.5 m). At each height, a Campbell Scientific CSAT3B sonic anemometer was operated to measure three velocity components and virtual temperature at 50 Hz, and an R. M. Young temperature and relative sensor was operated to measure air temperature and relative humidity at 1 Hz. The effective data collection was during March--April 2022, until the tower was taken down in April 2022. This was the first dataset of Arctic turbulence collected at 50 Hz, a frequency substantially higher than previous measurements at 10 Hz and 20 Hz. Given the strongly stable conditions in the Arctic, increasing the sampling frequency to 50 Hz was critical to resolve near-surface turbulence within or at least close to the inertial subrange. 
    more » « less
  3. An analysis is conducted to assess the sensitivity of 17 replicas of a saturated sloping deposit tests conducted within the 2017 Liquefaction Experiments and Analysis Projects (LEAP). A difference analysis is first used to quantify the dissimilarities between recorded input acceleration time histories. This analysis provided a unique decomposition of the differences in terms of phase, frequency-shift, amplitude at 1 Hz, and amplitude of frequency components higher than 2 Hz (2+Hz). A kriging analysis was used to evaluate the sensitivity of the deposit response accelerations to differences in input motion amplitude at 1Hz and 2+Hz and cone penetration resistance. The analysis showed a response that is more sensitive to variations in cone penetration resistance values than to amplitude of the input 1Hz and 2+Hz motion (frequency) components. 
    more » « less
  4. An analysis is conducted to assess the sensitivity of 17 replicas of a saturated sloping deposit tests conducted within the 2017 Liquefaction Experiments and Analysis Projects (LEAP). A difference analysis is first used to quantify the dissimilarities between recorded input acceleration time histories. This analysis provided a unique decomposition of the differences in terms of phase, frequency-shift, amplitude at 1 Hz, and amplitude of frequency components higher than 2 Hz (2+Hz). A kriging analysis was used to evaluate the sensitivity of the deposit response accelerations to differences in input motion amplitude at 1Hz and 2+Hz and cone penetration resistance. The analysis showed a response that is more sensitive to variations in cone penetration resistance values than to amplitude of the input 1Hz and 2+Hz motion (frequency) components. 
    more » « less
  5. An analysis is conducted to assess the sensitivity of 17 replicas of a saturated sloping deposit tests conducted within the 2017 Liquefaction Experiments and Analysis Projects (LEAP). A difference analysis is first used to quantify the dissimilarities between recorded input acceleration time histories. This analysis provided a unique decomposition of the differences in terms of phase, frequency-shift, amplitude at 1 Hz, and amplitude of frequency components higher than 2 Hz (2+Hz). A kriging analysis was used to evaluate the sensitivity of the deposit response accelerations to differences in input motion amplitude at 1Hz and 2+Hz and cone penetration resistance. The analysis showed a response that is more sensitive to variations in cone penetration resistance values than to amplitude of the input 1Hz and 2+Hz motion (frequency) components. 
    more » « less