skip to main content


Title: Contact Resonance Atomic Force Microscopy Using Long, Massive Tips
In this work, we present a new theoretical model for use in contact resonance atomic force microscopy. This model incorporates the effects of a long, massive sensing tip and is especially useful to interpret operation in the so-called trolling mode. The model is based on traditional Euler–Bernoulli beam theory, whereby the effect of the tip as well as of the sample in contact, modeled as an elastic substrate, are captured by appropriate boundary conditions. A novel interpretation of the flexural and torsional modes of vibration of the cantilever, when not in contact with the sample, is used to estimate the inertia properties of the long, massive tip. Using this information, sample elastic properties are then estimated from the in-contact resonance frequencies of the system. The predictive capability of the proposed model is verified via finite element analysis. Different combinations of cantilever geometry, tip geometry, and sample stiffness are investigated. The model’s accurate predictive ranges are discussed and shown to outperform those of other popular models currently used in contact resonance atomic force microscopy.  more » « less
Award ID(s):
1660448
NSF-PAR ID:
10125492
Author(s) / Creator(s):
; ;
Date Published:
Journal Name:
Sensors
Volume:
19
Issue:
22
ISSN:
1424-8220
Page Range / eLocation ID:
4990
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    In this work, a new theoretical model for contact resonance atomic force microscopy, which incorporates the elastic dynamics of a long sensing tip is presented. The model is based on the Euler–Bernoulli beam theory and includes coupling effects from the two-beam structure, also known as an ‘L-shaped’ beam in the literature. Here, high-accuracy prediction of the sample stiffness, using several vibration modes with a relative error smaller than 10% for practical working ranges, is demonstrated. A discussion on the model’s capability to predict the dynamic phenomena of eigenmode veering and crossing, as the force applied to the sample increases, is presented. The L-shaped beam model presented here is also applicable for structural applications such as: micro-electro-mechanical systems, energy harvesting, and unmanned aerial vehicle landing gear.

     
    more » « less
  2. Peak force infrared (PFIR) microscopy is an emerging atomic force microscopy (AFM)-based infrared microscopy that bypasses Abbe's diffraction limit on spatial resolution. The PFIR microscopy utilizes a nanoscopically sharp AFM tip to mechanically detect the tip-enhanced infrared photothermal response of the sample in the time domain. The time-gated mechanical signals of cantilever deflections transduce the infrared absorption of the sample, delivering infrared imaging and spectroscopy capability at sub 10 nm spatial resolution. Both the infrared absorption response and mechanical properties of the sample are obtained in parallel while preserving the surface integrity of the sample. This review describes the constructions of the PFIR microscope and several variations, including multiple-pulse excitation, total internal reflection geometry, dual-color configuration, liquid-phase operations, and integrations with simultaneous surface potential measurement. Representative applications of PFIR microscopy are also included in this review. In the outlook section, we lay out several future directions of innovations in PFIR microscopy and applications in chemical and material research. 
    more » « less
  3. Abstract In this work, we present an experimental validation of a new contact resonance atomic force microscopy model developed for sensors with long, massive tips. A derivation of a new technique and graphical method for the identification of the unknown system parameters is presented. The technique and contact resonance model are experimentally validated. The agreement between our contact resonance experimental measurements and values obtained from nanoindentation show a minimal error of 1.4%–4.5% and demonstrate the validity of the new contact resonance model and system parameter identification technique. 
    more » « less
  4. There is considerable interest in measuring, with nanoscale spatial resolution, the physical properties of lipid membranes because of their role in the physiology of living systems. Due to its ability to nondestructively image surfaces in solution, tapping mode atomic force microscopy (TMAFM) has proven to be a useful technique for imaging lipid membranes. However, further information concerning the mechanical properties of surfaces is contained within the time-resolved tip/sample force interactions. The tapping forces can be recovered by taking the second derivative of the cantilever deflection signal and scaling by the effective mass of the cantilever; this technique is referred to as scanning probe acceleration microscopy. Herein, we describe how the maximum and minimum tapping forces change with surface mechanical properties. Furthermore, we demonstrate how these changes can be used to measure mechanical changes in lipid membranes containing cholesterol. 
    more » « less
  5. Although graphene is well known for super-lubricity on its basal plane, friction at its step edge is not well understood and contradictory friction behaviors have been reported. In this study, friction of mono-layer thick graphene step edges was studied using atomic force microscopy (AFM) with a Si tip in dry nitrogen atmosphere. It is found that, when the tip slides over a ‘buried’ graphene step edge, there is a resistive force during the step-up motion and an assistive force during the step-down motion due to the topographic height change. The magnitude of these two forces is small and the same in both step-up and step-down motions. As for the ‘exposed’ graphene step edge, friction increases in magnitude and exhibits more complicated behaviors. During the step-down motion of the tip over the exposed step edge, both resistive and assistive components can be detected in the lateral force signal of AFM if the scan resolution is sufficiently high. The resistive component is attributed to chemical interactions between the functional groups at the tip and step-edge surfaces, and the assistive component is due to the topographic effect, same as the case of buried step edge. If a blunt tip is used, the distinct effects of these two components become more prominent. In the step-up scan direction, the blunt tip appears to have two separate topographic effects elastic deformation of the contact region at the bottom of the tip due to the substrate height change at the step edge and tilting of the tip while the vertical position of the cantilever (the end of the tip) ascends from the lower terrace to the upper terrace. The high-resolution measurement of friction behaviors at graphene step edges will further enrich understanding of interfacial friction behaviors on graphene-covered surfaces. 
    more » « less