Title: Relative Nucleus Pulposus Area and Position Alter Disk Joint Mechanics
Aging and degeneration of the intervertebral disk are noted by changes in tissue composition and geometry, including a decrease in nucleus pulposus (NP) area. The NP centroid is positioned slightly posterior of the disk's centroid, but the effect of NP size and location on disk joint mechanics is not well understood. We evaluated the effect of NP size and centroid location on disk joint mechanics under dual-loading modalities (i.e., compression in combination with axial rotation or bending). A finite element model (FEM) was developed to vary the relative NP area (NP:Disk area ratio range = 0.21–0.60). We also evaluated the effect of NP position by shifting the NP centroid anteriorly and posteriorly. Our results showed that compressive stiffness and average first principal strains increased with NP size. Under axial compression, stresses are distributed from the NP to the annulus, and stresses were redistributed toward the NP with axial rotation. Moreover, peak stresses were greater for disks with a smaller NP area. NP centroid location had a greater impact on intradiscal pressure during flexion and extension, where peak pressures in the posterior annulus under extension was greater for disks with a more posteriorly situated NP. In conclusion, the findings from this study highlight the importance of closely mimicking NP size and location in computational models that aim to understand stress/strain distribution during complex loading and for developing repair strategies that aim to recapitulate the mechanical behavior of healthy disks.  more » « less
Award ID(s):
1751212
PAR ID:
10161481
Author(s) / Creator(s):
; ; ;
Date Published:
Journal Name:
Journal of Biomechanical Engineering
Volume:
141
Issue:
5
ISSN:
0148-0731
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Abstract Painful herniated discs are treated surgically by removing extruded nucleus pulposus (NP) material (nucleotomy). NP removal through enzymatic digestion is also commonly performed to initiate degenerative changes to study potential biological repair strategies. Experimental and computational studies have shown a decrease in disc stiffness with nucleotomy under single loading modalities, such as compression-only or bending-only loading. However, studies that apply more physiologically relevant loading conditions, such as compression in combination with bending or torsion, have shown contradicting results. We used a previously validated bone–disc–bone finite element model (Control) to create a Nucleotomy model to evaluate the effect of dual loading conditions (compression with torsion or bending) on intradiscal deformations. While disc joint stiffness decreased with nucleotomy under single loading conditions, as commonly reported in the literature, dual loading resulted in an increase in bending stiffness. More specifically, dual loading resulted in a 40% increase in bending stiffness under flexion and extension and a 25% increase in stiffness under lateral bending. The increase in bending stiffness was due to an increase and shift in compressive stress, where peak stresses migrated from the NP–annulus interface to the outer annulus. In contrast, the decrease in torsional stiffness was due to greater fiber reorientation during compression. In general, large radial strains were observed with nucleotomy, suggesting an increased risk for delamination or degenerative remodeling. In conclusion, the effect of nucleotomy on disc mechanics depends on the type and complexity of applied loads. 
    more » « less
  2. Cervical laminoplasty is a valuable procedure for myelopathy but it is associated with complications such as increased kyphosis. The effect of ligament damage during cervical laminoplasty on biomechanics is not well understood. We developed the C2–C7 cervical spine finite element model and simulated C3–C6 double-door laminoplasty. Three models were created (a) intact, (b) laminoplasty-pre (model assuming that the ligamentum flavum (LF) between C3–C6 was preserved during surgery), and (c) laminoplasty-res (model assuming that the LF between C3–C6 was resected during surgery). The models were subjected to physiological loading, and the range of motion (ROM), intervertebral nucleus stress, and facet contact forces were analyzed under flexion/extension, lateral bending, and axial rotation. The maximum change in ROM was observed under flexion motion. Under flexion, ROM in the laminoplasty-pre model increased by 100.2%, 111.8%, and 98.6% compared to the intact model at C3–C4, C4–C5, and C5–C6, respectively. The ROM in laminoplasty-res further increased by 105.2%, 116.8%, and 101.8% compared to the intact model at C3–C4, C4–C5, and C5–C6, respectively. The maximum stress in the annulus/nucleus was observed under left bending at the C4–C5 segment where an increase of 139.5% and 229.6% compared to the intact model was observed for laminoplasty-pre and laminoplasty-res model, respectively. The highest facet contact forces were observed at C4–C5 under axial rotation, where an increase of 500.7% and 500.7% was observed compared to the intact model for laminoplasty-pre and laminoplasty-res, respectively. The posterior ligaments of the cervical spine play a vital role in restoring/stabilizing the cervical spine. When laminoplasty is performed, the surgeon needs to be careful not to injure the posterior soft tissue, including ligaments such as LF. 
    more » « less
  3. Abstract PurposeTo assess the effect of various pelvic fixation techniques and number of rods on biomechanics of the proximal junction of long thoracolumbar posterior instrumented fusions. MethodsA validated spinopelvic finite-element (FE) model was instrumented with L5–S1 ALIF and one of the following 9 posterior instrumentation configurations: (A) one traditional iliac screw bilaterally (“2 Iliac/2 Rods”); (B) T10 to S1 (“Sacral Only”); (C) unilateral traditional iliac screw (“1 Iliac/2 Rods”); (D) one traditional iliac screw bilaterally with one midline accessory rod (“2 Iliac/3 rods”); (E) S2AI screws connected directly to the midline rods (“2 S2AI/2 Rods”); and two traditional iliac screws bilaterally with two lateral accessory rods connected to the main rods at varying locations (F1: T10–11, F2: T11–12, F3: T12–L1, F4: L1–2) (“4 Iliac/4 Rods”). Range of motions (ROM) at T10–S1 and T9–T10 were recorded and compared between models. The T9–T10 intradiscal pressures and stresses of the T9–10 disc’s annulus in addition to the von Mises stresses of the T9 and T10 vertebral bodies were recorded and compared. ResultsFor T10–S1 ROM, 4 iliac/4 rods had lowest ROM in flexion and extension, while 2 S2AI/2 rods showed lowest ROM in rotation. Constructs with 3 or 4 rods had lower stresses on the primary rods compared to 2-rod constructs. At the proximal adjacent disc (T9–10), 4 iliac/4 rods showed lowest ROM, lowest intradiscal pressures, and lowest annular stress in all directions (most pronounced in flexion–extension). Under flexion and extension, 4 iliac/4 rods also showed the lowest von Mises stresses on the T10 vertebral body but the highest stresses on the T9 vertebral body. ConclusionsDual iliac screws with 4 rods across the lumbosacral junction and extending to the thoracolumbar junction demonstrated the lowest T10–S1 ROM, the lowest adjacent segment disc (T9–T10) ROM, intradiscal pressures, and annular stresses, and the lowest UIV stresses, albeit with the highest UIV + 1 stresses. Additional studies are needed to confirm whether these biomechanical findings dictate clinical outcomes and effect rates of proximal junctional kyphosis and failure. 
    more » « less
  4. Abstract The intervertebral disc is a complex structure that experiences multiaxial stresses regularly. Disc failure through herniation is a common cause of lower back pain, which causes reduced mobility and debilitating pain, resulting in heavy socioeconomic burdens. Unfortunately, herniation etiology is not well understood, partially due to challenges in replicating herniation in vitro. Previous studies suggest that flexion elevated risks of herniation. Thus, the objective of this study was to use a multiscale and multiphasic finite element model to evaluate the risk of failure under torque- or muscle-driven flexion. Models were developed to represent torque-driven flexion with the instantaneous center of rotation (ICR) located on the disc, and the more physiologically representative muscle-driven flexion with the ICR located anterior of the disc. Model predictions highlighted disparate disc mechanics regarding bulk deformation, stress-bearing mechanisms, and intradiscal stress–strain distributions. Specifically, failure was predicted to initiate at the bone-disc boundary under torque-driven flexion, which may explain why endplate junction failure, instead of herniation, has been the more common failure mode observed in vitro. By contrast, failure was predicted to initiate in the posterolateral annulus fibrosus under muscle-driven flexion, resulting in consistent herniation. Our findings also suggested that muscle-driven flexion combined with axial compression could be sufficient for provoking herniation in vitro and in silico. In conclusion, this study provided a computational framework for designing in vitro testing protocols that can advance the assessment of disc failure behavior and the performance of engineered disc implants. 
    more » « less
  5. Abstract In recent years, continuum-reverberation mapping involving high-cadence UV/optical monitoring campaigns of nearby active galactic nuclei has been used to infer the size of their accretion disks. One of the main results from these campaigns has been that in many cases the accretion disks appear too large, by a factor of 2–3, compared to standard models. Part of this may be due to diffuse continuum emission from the broad-line region (BLR), which is indicated by excess lags around the Balmer jump. Standard cross-correlation lag-analysis techniques are usually used to just recover the peak or centroid lag and cannot easily distinguish between reprocessing from the disk and BLR. However, frequency-resolved lag analysis, where the lag is determined at each Fourier frequency, has the potential to separate out reprocessing on different size scales. Here we present simulations to demonstrate the potential of this method and then apply a maximum-likelihood approach to determine frequency-resolved lags in NGC 5548. We find that the lags in NGC 5548 generally decrease smoothly with increasing frequency, and are not easily described by accretion-disk reprocessing alone. The standard cross-correlation lags are consistent with lags at frequencies lower than 0.1 day−1, indicating they are dominated from reprocessing at size scales greater than ∼10 light days. A combination of a more distant reprocessor, consistent with the BLR, along with a standard-sized accretion disk is more consistent with the observed lags than a larger disk alone. 