Limited approaches exist for imaging and recording spectra of individual nanostructures in the midinfrared region. Here we use infrared photothermal heterodyne imaging (IR-PHI) to interrogate single, high aspect ratio Au nanowires (NWs). Spectra recorded between 2,800 and 4,000 cm−1for 2.5–3.9-μm-long NWs reveal a series of resonances due to the Fabry–Pérot modes of the NWs. Crucially, IR-PHI images show structure that reflects the spatial distribution of the NW absorption, and allow the resonances to be assigned to them= 3 andm= 4 Fabry–Pérot modes. This far-field optical measurement has been used to image the mode structure of plasmon resonances in metal nanostructures, and is made possible by the superresolution capabilities of IR-PHI. The linewidths in the NW spectra range from 35 to 75 meV and, in several cases, are significantly below the limiting values predicted by the bulk Au Drude damping parameter. These linewidths imply long dephasing times, and are attributed to reduction in both radiation damping and resistive heating effects in the NWs. Compared to previous imaging studies of NW Fabry–Pérot modes using electron microscopy or near-field optical scanning techniques, IR-PHI experiments are performed under ambient conditions, enabling detailed studies of how the environment affects mid-IR plasmons.
more »
« less
Approaches to mid-infrared, super-resolution imaging and spectroscopy
This perspective highlights recent advances in super-resolution, mid-infrared imaging and spectroscopy. It provides an overview of the different near field microscopy techniques developed to address the problem of chemically imaging specimens in the mid-infrared “fingerprint” region of the spectrum with high spatial resolution. We focus on a recently developed far-field optical technique, called infrared photothermal heterodyne imaging (IR-PHI), and discusses the technique in detail. Its practical implementation in terms of equipment used, optical geometries employed, and underlying contrast mechanism are described. Milestones where IR-PHI has led to notable advances in bioscience and materials science are summarized. The perspective concludes with a future outlook for robust and readily accessible high spatial resolution, mid-infrared imaging and spectroscopy techniques.
more »
« less
- Award ID(s):
- 1902403
- PAR ID:
- 10168021
- Date Published:
- Journal Name:
- Physical Chemistry Chemical Physics
- Volume:
- 22
- Issue:
- 8
- ISSN:
- 1463-9076
- Page Range / eLocation ID:
- 4313 to 4325
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
An approach is described for spectrally parallel hyperspectral mid-infrared imaging with spatial resolution dictated by fluorescence imaging. Quantum cascade laser (QCL)-based dual-comb mid-infrared spectroscopy enables the acquisition of infrared spectra at high speed (<1 millisecond) through the generation of optical beat patterns and radio-frequency detection. The high-speed nature of the spectral acquisition is shown to support spectral mapping in microscopy measurements. Direct detection of the transmitted infrared beam yields high signal-to-noise spectral information, but long infrared wavelengths impose low diffraction-limited spatial resolution. The use of fluorescence detected photothermal infrared (F-PTIR) imaging provides high spatial resolution tied directly to the integrated IR absorption. Computational imaging using a multi-agent consensus equilibrium (MACE) approach combines the high spatial resolution of F-PTIR and the high spectral information of dual-comb infrared transmission in a single optimized equilibrium hyperspectral data cube.more » « less
-
Gregor, Ingo; Erdmann, Rainer; Koberling, Felix (Ed.)Infrared photothermal heterodyne imaging (IR-PHI) represents a convenient table top approach for conducting superresolution imaging and spectroscopy throughout the all-important mid infrared (MIR) spectral region. Although IR-PHI provides label-free, superresolution MIR absorption information, it is not quantitative. In this study, we establish quantitative relationships between observed IR-PHI signals and relevant photothermal parameters of investigated specimens. Specifically, we conduct a size series analysis of different radii polystyrene (PS) beads so as to quantitatively link IR-PHI signal contrast to specimen heat capacity, MIR peak absorption cross-section, and scattering cross-section at IR-PHI’s probe wavelength.more » « less
-
We review the recent advances in thermal characterization of micro/nanoscale electronic, optoelectronic, thermal devices based on thermoreflectance imaging. Thermoreflectance imaging is a non-invasive optical technique that can visualize surface thermal response of devices and integrated circuits (IC). Recent advances of the technique have enabled high-resolution, ultra-fast transient thermal imaging with 800 ps temporal resolution. Using visible or UV illumination, spatial resolution of about 200-250 nm can be achieved. Many IC substrates, e.g. Si, GaAs, are transparent to near IR illumination in 1-1.5 μm wavelength range. Through-substrate thermal imaging of flip-chip bonded ICs with micron spatial resolution has been demonstrated. We provide key examples of various devices characterized by the technique such as CMOS ICs, GaN HEMT, nanowire transistors, thin-film solar cells, and micro-thermal cloaking devices. In addition to the validation of electrothermal models, material and fabrication defects can be identified. Finally we discuss the advantages/limitations, and perspective of thermoreflectance imaging technique.more » « less
-
Mid-infrared Spectroscopic Imaging (MIRSI) provides spatially-resolved molecular specificity by measuring wavelength-dependent mid-infrared absorbance. Infrared microscopes use large numerical aperture objectives to obtain high-resolution images of heterogeneous samples. However, the optical resolution is fundamentally diffraction-limited, and therefore wavelength-dependent. This significantly limits resolution in infrared microscopy, which relies on long wavelengths (2.5 μm to 12.5 μm) for molecular specificity. The resolution is particularly restrictive in biomedical and materials applications, where molecular information is encoded in the fingerprint region (6 μm to 12 μm), limiting the maximum resolving power to between 3 μm and 6 μm. We present an unsupervised curvelet-based image fusion method that overcomes limitations in spatial resolution by augmenting infrared images with label-free visible microscopy. We demonstrate the effectiveness of this approach by fusing images of breast and ovarian tumor biopsies acquired using both infrared and dark-field microscopy. The proposed fusion algorithm generates a hyperspectral dataset that has both high spatial resolution and good molecular contrast. We validate this technique using multiple standard approaches and through comparisons to super-resolved experimentally measured photothermal spectroscopic images. We also propose a novel comparison method based on tissue classification accuracy.more » « less
An official website of the United States government

