Title: Validating the Comparison Framework for the Finite Dimensions Model of Concentric Ring Electrodes Using Human Electrocardiogram Data
While progress has been made in design optimization of concentric ring electrodes maximizing the accuracy of the surface Laplacian estimation, it was based exclusively on the negligible dimensions model of the electrode. Recent proof of concept of the new finite dimensions model that adds the radius of the central disc and the widths of concentric rings to the previously included number of rings and inter-ring distances provides an opportunity for more comprehensive design optimization. In this study, the aforementioned proof of concept was developed into a framework allowing direct comparison of any two concentric ring electrodes of the same size and with the same number of rings. The proposed framework is illustrated on constant and linearly increasing inter-ring distances tripolar concentric ring electrode configurations and validated on electrocardiograms from 20 human volunteers. In particular, ratios of truncation term coefficients between the two electrode configurations were used to demonstrate the similarity between the negligible and the finite dimension models analytically (p = 0.077). Laplacian estimates based on the two models were calculated on electrocardiogram data for emulation of linearly increasing inter-ring distances tripolar concentric ring electrode. The difference between the estimates was not statistically significant (p >> 0.05) which is consistent with the analytic result.  more » « less
Award ID(s):
1914787 1622481
PAR ID:
10177446
Author(s) / Creator(s):
; ; ; ; ;
Date Published:
Journal Name:
Applied Sciences
Volume:
9
Issue:
20
ISSN:
2076-3417
Page Range / eLocation ID:
4279
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Concentric ring electrodes are noninvasive and wearable sensors for electrophysiological measurement capable of estimating the surface Laplacian (second spatial derivative of surface potential) at each electrode. Significant progress has been made toward optimization of inter-ring distances (distances between the recording surfaces of the electrode), maximizing the accuracy of the surface Laplacian estimate based on the negligible dimensions model of the electrode. However, novel finite dimensions model offers comprehensive optimization including all of the electrode parameters simultaneously by including the radius of the central disc and the widths of the concentric rings into the model. Recently, such comprehensive optimization problem has been solved analytically for the tripolar electrode configuration. This study, for the first time, introduces a finite dimensions model based finite element method model (as opposed to the negligible dimensions model based one used in the past) to confirm the analytic results. Specifically, finite element method modeling results confirmed that previously proposed linearly increasing inter-ring distances and constant inter-ring distances configurations of tripolar concentric ring electrodes correspond to an almost two-fold and more than three-fold increases in relative and normalized maximum errors of Laplacian estimation when directly compared to the optimal tripolar concentric ring electrode configuration of the same size. 
    more » « less
  2. The optimization performed in this study is based on the finite dimensions model of the concentric ring electrode as opposed to the negligible dimensions model used in the past. This makes the optimization problem comprehensive, as all of the electrode parameters including, for the first time, the radius of the central disc and individual widths of concentric rings, are optimized simultaneously. The optimization criterion used is maximizing the accuracy of the surface Laplacian estimation, as the ability to estimate the Laplacian at each electrode constitutes primary biomedical significance of concentric ring electrodes. For tripolar concentric ring electrodes, the optimal configuration was compared to previously proposed linearly increasing inter-ring distances and constant inter-ring distances configurations of the same size and based on the same finite dimensions model. The obtained analytic results suggest that previously proposed configurations correspond to almost two-fold and more than three-fold increases in the Laplacian estimation error compared with the optimal configuration proposed in this study, respectively. These analytic results are confirmed using finite element method modeling, which was adapted to the finite dimensions model of the concentric ring electrode for the first time. Moreover, the finite element method modeling results suggest that optimal electrode configuration may also offer improved sensitivity and spatial resolution. 
    more » « less
  3. Vallan, Alberto (Ed.)
    Concentric ring electrodes are noninvasive and wearable sensors for electrophysiological measurement capable of estimating the surface Laplacian (second spatial derivative of surface potential) at each electrode. Previously, progress was made toward optimization of inter-ring distances (distances between the recording surfaces of a concentric ring electrode), maximizing the accuracy of the surface Laplacian estimate based on the negligible dimensions model of the electrode. However, this progress was limited to tripolar (number of concentric rings n equal to 2) and quadripolar (n = 3) electrode configurations only. In this study, the inter-ring distances optimization problem is solved for pentapolar (n = 4) and sextopolar (n = 5) concentric ring electrode configurations using a wide range of truncation error percentiles ranging from 1st to 25th. Obtained results also suggest consistency between all the considered concentric ring electrode configurations corresponding to n ranging from 2 to 5 that may allow estimation of optimal ranges of inter-ring distances for electrode configurations with n ≥ 6. Therefore, this study may inform future concentric ring electrode design for n ≥ 4 which is important since the accuracy of surface Laplacian estimation has been shown to increase with an increase in n. 
    more » « less
  4. Falcone, Francisco (Ed.)
    Concentric ring electrodes are showing promise in noninvasive electrophysiological measurement but electrode design criteria are rarely detailed and justified. Toward that goal, the use of realistic finite dimensions model of concentric ring electrode in this study was two-fold. First, it was used to optimize the surface Laplacian estimate coefficients for tripolar electrode configuration with dimensions approximating the commercially available t-Lead electrodes manufactured by CREmedical. Two differential signals representing differences between potentials on the middle ring and on the central disc as well as on the outer ring and on the central disc are combined linearly into the Laplacian estimate with aforementioned coefficients representing the weights of differential signals. Second, it was used to directly compare said tripolar configuration to the optimal tripolar concentric ring electrode configuration of the same size via finite element method modeling based computation of relative and normalized maximum errors of Laplacian estimation. Obtained results suggest the optimal coefficients for Laplacian estimate based on the approximation of the t-Lead dimensions to be (6, -1) as opposed to (16, -1) widely used with this electrode in the past. Moreover, compared to the optimal tripolar concentric ring electrode configuration, commercially available tripolar electrode of the same size leads to a median increase in Laplacian estimation errors of over 4 times. These results are consistent with previously obtained results based on both negligible and finite dimensions models but further investigation on real life phantom and human data via physical concentric ring electrode prototypes is needed for conclusive proof. 
    more » « less
  5. Surface Laplacian estimates via concentric ring electrodes (CREs) have proven to enhance spatial resolution compared to conventional disc electrodes, which is of great importance for P-wave analysis. In this study, Laplacian estimates for traditional bipolar configuration (BC), two tripolar configurations with linearly decreasing and increasing inter-ring distances (TCLDIRD and TCLIIRD, respectively), and quadripolar configuration (QC) were obtained from cardiac recordings with pentapolar CREs placed at CMV1 and CMV2 positions. Normalized P-wave amplitude (NAP) was computed to assess the contrast to study atrial activity. Signals were of good quality (20–30 dB). Atrial activity was more emphasized at CMV1 (NAP ≃ 0.19–0.24) compared to CMV2 (NAP ≃ 0.08–0.10). Enhanced spatial resolution of TCLIIRD and QC resulted in higher NAP values than BC and TCLDIRD. Comparison with simultaneous standard 12-lead ECG proved that Laplacian estimates at CMV1 outperformed all the limb and chest standard leads in the contrast to study P-waves. Clinical recordings with CRE at this position could allow more detailed observation of atrial activity and facilitate the diagnosis of associated pathologies. Furthermore, such recordings would not require additional electrodes on limbs and could be performed wirelessly, so it should also be suitable for ambulatory monitoring, for example, using cardiac Holter monitors. 
    more » « less