skip to main content


Title: High resolution, fast response fiber-optic temperature sensor with reduced end conduction effect

We report a fiber-optic silicon Fabry–Perot temperature sensor with high speed by considering the end conduction effect, which refers to the unwanted heat transfer between the sensing element and the fiber stub delaying the sensor from reaching thermal equilibrium with the ambient environment. The sensor is constructed by connecting the narrow edge surface of a thin silicon plate to the edge of the microtube attached to the fiber tip. Compared to the traditional design where the silicon plate is attached to the fiber end face on its large plate surface, the new sensor design minimizes the heat transfer path to the fiber stub for improved sensor speed. It has the additional benefit of increased cavity length for improved resolution. We show that, compared with the sensor of traditional design, the sensor of the new design shortened the characteristic response time in still air from 83 ms to 13 ms and improved the sensor resolution by a factor of 12, from 0.15 K to 0.012 K.

 
more » « less
Award ID(s):
1808436 1918074
NSF-PAR ID:
10200395
Author(s) / Creator(s):
; ; ; ; ; ;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Optics Letters
Volume:
45
Issue:
21
ISSN:
0146-9592; OPLEDP
Page Range / eLocation ID:
Article No. 6094
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Rationale

    Successful coupling of a multi‐ionization automated platform with commercially available mass spectrometers provides improved coverage of compounds in complex mixtures through implementation of new and traditional ionization methods. The versatility of the automated platform is demonstrated through coupling with mass spectrometers from two different vendors. Standards and complex biological samples were acquired using electrospray ionization (ESI), solvent‐assisted ionization (SAI) and matrix‐assisted ionization (MAI).

    Methods

    The MS™ prototype automated platform samples from 96‐ or 384‐well plates as well as surfaces. The platform interfaces with Thermo Fisher Scientific mass spectrometers by replacement of the IonMax source, and on Waters mass spectrometers with additional minor source inlet modifications. The sample is transferred to the ionization region using a fused‐silica or metal capillary which is cleaned between acquisitions using solvents. For ESI and SAI, typically 1 μL of sample solution is drawn into the capillary tube and for ESI slowly dispensed near the inlet of the mass spectrometer with voltage placed on the delivering syringe barrel to which the tubing is attached, while for SAI the sample delivery tubing inserts into the inlet without the need for high voltage. For MAI, typically, 0.2 μL of matrix solution is drawn into the syringe before drawing 0.1 μL of the sample solution and dispensing to dry before insertion into the inlet.

    Results

    A comparison study of a mixture of angiotensin I, verapamil, crystal violet, and atrazine representative of peptides, drugs, dyes, and herbicides using SAI, MAI, and ESI shows large differences in ionization efficiency of the various components. Solutions of a mixture of erythromycin and azithromycin in wells of a 384‐microtiter well plate were mass analyzed at the rate ofca1 min per sample using MAI and ESI. In addition, we report the analysis of bacterial extracts using automated MAI and ESI methods. Finally, the ability to perform surface analysis with the automated platform is also demonstrated by directly analyzing dyes separated on a thin‐layer chromatography (TLC) plate and compounds extracted from the surface of a beef liver tissue section.

    Conclusions

    The prototype multi‐ionization automated platform offers solid matrix introduction used with MAI, as well as solution introduction using either ESI or SAI. The combination of ionization methods extends the types of compounds which are efficiently ionized and is especially valuable with complex mixtures as demonstrated for bacterial extracts. While coupling of the automated multi‐ionization platform to Thermo and Waters mass spectrometers is demonstrated, it should be possible to interface it with most commercial mass spectrometers.

     
    more » « less
  2. Solar thermoelectric generators (STEGs) often require long thermoelectric (TE) legs and efficient cooling at the cold side to increase the temperature difference across TE legs and, thus, the power output. We investigate the effects of direct side-wall air cooling of TE legs on the power output of STEGs fabricated with high aspect-ratio as well as V-shaped p-type and n-type TE couples without additional heat sinks. Wire-type metallic TE materials are welded together to create V-shape TE leg arrays without additional electrodes and attached to a ceramic plate with a solar absorber on top to complete the STEG. The power generation performance of the STEG is investigated with varying wind speed under concentrated solar irradiation. Finite element simulation is performed to further analyze the heat transfer and thermoelectric performance. We find that although sidewall air cooling helps to keep the cold-side temperature cooler in both natural and forced convection regimes, it can also lower the hot-side temperature to reduce the net temperature difference and, thus, the power output and efficiency. Partial thermal insulation of TE couples can further enhance the power output under forced air convection by keeping the hot side temperature higher. The developed STEG achieves a maximum power density of 230 μW/cm2 and a system efficiency of 0.023% under 10 suns with natural convection. The low efficiency was mainly due to the low ZT of the metallic TE materials used and the unoptimized leg length. Our simulation shows that the system efficiency can be improved to 2.8% with state-of-the-art Bi2Te3 alloys at an optimal leg length. 
    more » « less
  3. The weak-wind boundary layer is characterized by turbulent and submeso-scale motions that break the assumptions necessary for using traditional eddy covariance observations such as horizontal homogeneity and stationarity, motivating the need for an observational system that allows spatially resolving measurements of atmospheric flows near the surface. Fiber-Optic Distributed Sensing (FODS) potentially opens the door to observing a wide-range of atmospheric processes on a spatially distributed basis and to date has been used to resolve the turbulent fields of air temperature and wind speed on scales of second and decimeters. Here we report on progress developing a FODS technique for observing spatially distributed wind direction. We affixed microstructures shaped as cones to actively-heated fiber-optic cables with opposing orientations to impose directionally-sensitive convective heat fluxes from the fiber-optic cable to the air, leading to a difference in sensed temperature that depends on the wind direction. We demonstrate the behavior of a range of microstructure parameters including aspect ratio, spacing, and size and develop a simple deterministic model to explain the temperature differences as a function of wind speed. The mechanism behind the directionally-sensitive heat loss is explored using Computational Fluid Dynamics simulations and infrared images of the cone-fiber system. While the results presented here are only relevant for observing wind direction along one dimension it is an important step towards the ultimate goal of a full three-dimensional, distributed flow sensor. 
    more » « less
  4. Extreme heat puts tremendous stress on human health and limits people’s ability to work, travel, and socialize outdoors. To mitigate heat in public spaces, thermal conditions must be assessed in the context of human exposure and space use. Mean Radiant Temperature (MRT) is an integrated radiation metric that quantifies the total heat load on the human body and is a driving parameter in many thermal comfort indices. Current sensor systems to measure MRT are expensive and bulky (6-directional setup) or slow and inaccurate (globe thermometers) and do not sense space use. This engineering systems paper introduces the hardware and software setup of a novel, low-cost thermal and visual sensing device (MaRTiny). The system collects meteorological data, concurrently counts the number of people in the shade and sun, and streams the results to an Amazon Web Services (AWS) server. MaRTiny integrates various micro-controllers to collect weather data relevant to human thermal exposure: air temperature, humidity, wind speed, globe temperature, and UV radiation. To detect people in the shade and Sun, we implemented state of the art object detection and shade detection models on an NVIDIA Jetson Nano. The system was tested in the field, showing that meteorological observations compared reasonably well to MaRTy observations (high-end human-biometeorological station) when both sensor systems were fully sun-exposed. To overcome potential sensing errors due to different exposure levels, we estimated MRT from MaRTiny weather observations using machine learning (SVM), which improved RMSE. This paper focuses on the development of the MaRTiny system and lays the foundation for fundamental research in urban climate science to investigate how people use public spaces under extreme heat to inform active shade management and urban design in cities. 
    more » « less
  5. Abstract

    Cryogenic‐computing draws attention due to its variety of applications such as cloud‐computing, aerospace electronics, and quantum computing. Low temperature (e.g., 77 K) enables higher switching speed, improved reliability, and suppressed noise. Although cryogenic dynamic random‐access memory is studied, the cryogenic NAND flash is not explored intensively. Herein, a cryogenic storage memory based on the charge‐trap mechanism is reported. By removing the tunneling oxide from the conventional silicon/oxide/nitride/oxide/silicon (SONOS)‐type flash memory (therefore becoming silicon/oxide/nitride/silicon (SONS)), high‐speed and low‐power operation is aimed to be achieved while relieved from poor retention issue thanks to the cryogenic environment. The FinFET‐structured SONS memory device is demonstrated experimentally with gate length of 20–30 nm, which can achieve the retention issue (>10 years) with low voltage (≈6.5 V) and high speed (≈5 µs) operation at 77 K. To have a holistic system‐level evaluation, benchmark simulation of an interface between a host microprocessor and solid‐state‐drive is conducted, considering the refrigerator cooling cost and the heat loss via cables across two temperatures (300 and 77 K). The results show that the SONS‐type cryogenic storage system shows over 81% improvement in both latency and power, compared to the SONOS counterpart located at cryogenics.

     
    more » « less