skip to main content


Title: Developing a Smart Façade System Controller for Wind-Induced Vibration Mitigation in Tall Buildings
Tall and slender buildings often endure disturbances resulting from winds composed of various mean and fluctuating velocities. These disturbances result in discomfort for the occupants as well as accelerated fatigue life cycles and premature fatigue failures in the building. This work presents the development of a smart morphing façade (Smorphaçade) system that dynamically alters a buildings’ external shape or texture to minimize the effect of wind-induced vibrations on the building. The Smorphacade system is represented in this work by a series of plates that vary their orientation by means of a central controller module. To validate the simulation, a simple NACA0012 airfoil is simulated in a stream of air at a Reynolds number (RE) of 2 million. The pressure and viscous force profiles are captured to plot the variation of the lift force for different angles of attack that are then validated using published experimental airfoil data. After validation, the airfoil is attached to a linear spring-damper combination and is allowed to translate vertically without rotation according to the force profile captured from the surrounding air stream. A PID controller is developed to equilibrate the vertical position of the airfoil by altering its angle of attack. The model and its utility functions are implemented as an OpenFOAM® module (MSLSolid). Thereafter, the model is expanded to handle a planar case of a building floor carrying 4 controllable plates. The forces on the building profile are summed at the centroid of the building and the windward rigid body motion of the floor is estimated by reflecting the horizontal force component on a Finite Element (FE) model of the building. The time series information of the force acting on the building and the resulting oscillations are captured for exhaustive combinations of the plate angles. This data is used to build a lookup table that gives the best plate configuration for a given wind condition. A controller operates in real-time by searching the lookup table using readings of the wind condition. Preliminary results show a 94% reduction in the amplitudes of wind-induced vibrations.  more » « less
Award ID(s):
1826364
NSF-PAR ID:
10204345
Author(s) / Creator(s):
;
Date Published:
Journal Name:
Smart Materials, Adaptive Structures and Intelligent Systems
Volume:
59131
Page Range / eLocation ID:
V001T03A011
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Zonta, Daniele ; Su, Zhongqing ; Glisic, Branko (Ed.)
    This work presents a control scheme for wind-induced vibration mitigation for tall buildings based on a gated recurrent unit (GRU) encoder-decoder model which operates using readings from multiple sensors to define a unique system state. The sensors include a distributed network of pressure probes installed on surrounding buildings, accelerometers installed on the principal building, and atmospheric conditions. The encoder-decoder GRU is trained from timeseries sensor readings to construct a unique internal representation (hidden state) of the evolving wind and building conditions. A 1:400-scale aeroelastic building model with motorized plates acting as aerodynamic control surfaces is used in wind tunnel experiments to conduct this study. An online genetic reinforcement learning (GRL) algorithm uses a series of multilayer perceptron (MLP) networks to determine optimum actuator orientations for different flow conditions. The algorithm stores previously discovered solutions in the MLPs sorted by their fitness. The GA operates by obtaining a solution from each of the MLPs and performing GA operations on them to choose the next combination of plate angles to try. A chance also exists for trying completely random plate angles to prevent the GA from stalling. The MLPs are continuously trained during online optimization using findings obtained from new trials. The system eliminates the need for holding wind conditions, which are uncontrollable, constant during online training but still uses a pseudo-random search technique to obtain global optimum solutions. Results show a considerable reduction in building RMS acceleration when compared with a large collection of results with random constant plate angle orientations. 
    more » « less
  2. null (Ed.)
    Cables of suspension, cable-stayed and tied-arch bridges, suspended roofs, and power transmission lines are prone to moderate to large-amplitude vibrations in wind because of their low inherent damping. Structural or fatigue failure of a cable, due to these vibrations, pose a significant threat to the safety and serviceability of these structures. Over the past few decades, many studies have investigated the mechanisms that cause different types of flow-induced vibrations in cables such as rain-wind induced vibration (RWIV), vortex-induced vibration (VIV), iced cable galloping, wake galloping, and dry-cable galloping that have resulted in an improved understanding of the cause of these vibrations. In this study, the parameters governing the turbulence-induced (buffeting) and motion-induced wind loads (self-excited) for inclined and yawed dry cables have been identified. These parameters facilitate the prediction of their response in turbulent wind and estimate the incipient condition for onset of dry-cable galloping. Wind tunnel experiments were performed to measure the parameters governing the aerodynamic and aeroelastic forces on a yawed dry cable. This study mainly focuses on the prediction of critical reduced velocity 〖(RV〗_cr) as a function of equivalent yaw angle (*) and Scruton number (Sc) through measurement of aerodynamic- damping and stiffness. Wind tunnel tests using a section model of a smooth cable were performed under uniform and smooth/gusty flow conditions in the AABL Wind and Gust Tunnel located at Iowa State University. Static model tests for equivalent yaw angles of 0º to 45º indicate that the mean drag coefficient 〖(C〗_D) and Strouhal number (St) of a yawed cable decreases with the yaw angle, while the mean lift coefficient 〖(C〗_L) remains zero in the subcritical Reynolds number (Re) regime. Dynamic one degree-of-freedom model tests in across-wind and along-wind directions resulted in the identification of buffeting indicial derivative functions and flutter derivatives of a yawed cable for a range of equivalent yaw angles. Empirical equations for mean drag coefficient, Strouhal number, buffeting indicial derivative functions and critical reduced velocity for dry-cable galloping are proposed for yawed cables. The results indicate a critical equivalent yaw angle of 45° for dry-cable galloping. A simplified design procedure is introduced to estimate the minimum damping required to arrest dry-cable galloping from occurring below the design wind speed of the cable structure. Furthermore, the results from this study can be applied to predict the wind load and response of a dry cable at a specified wind speed for a given yaw angle. 
    more » « less
  3. We numerically examine the use of Gurney flap to modify the two-dimensional wake dynamics for lift enhancement on NACA 0000 (flat plate), 0006, 0012 and 0018 airfoils. Incompressible flows over the airfoils at different angles of attack are considered at Re = 1000. It is observed that the attachment of the Gurney flap at the trailing edge is able to enhance the lift force experienced by the airfoil appreciably with increase in Gurney flap height. The lift-to-drag ratio of the airfoils is also observed to increase at lower angles of attack. The lift spectra and airfoil wake are examined to reveal the effect of the Gurney flap on the formation of different characteristic wake modes and the associated change in the aerodynamic forces exerted on the airfoils. Based on the observations, we classify the resulting wakes into four distinct modes. The emergence of these modes (steady, 2S, P and 2P) are mapped over a wide range of angles of attack and Gurney flap heights for all four airfoils in consideration. 
    more » « less
  4. The motion of cladding systems can be leveraged to mitigate natural and man-made hazards. The literature counts various examples of connections enhanced with passive energy dissipation capabilities at connections. However, because such devices are passive, their mitigation performance is typically limited to specific excitations. The authors have recently proposed a novel variable friction cladding connection capable of mitigating hazards semi-actively. The variable friction cladding connection is engineered to transfer lateral forces from the cladding element to the structural system. Its variation in friction force is generated by a toggle-actuated variable normal force applied onto sliding friction plates. In this study, a multiobjective motion-based design methodology integrating results from the previous work is proposed to leverage the variable friction cladding connection for nonsimultaneous wind, seismic, and blast hazard mitigation. The procedure starts with the quantification of each hazard and performance objectives. It is followed by the selection of dynamic parameters enabling prescribed performance under wind and seismic loads, after which an impact rubber bumper is designed to satisfy motion requirements under blast. Last, the peak building responses are computed and iterations conducted on the design parameters on the satisfaction of the motion objectives. The motion-based design procedure is verified through numerical simulations on two example buildings subjected to the three nonsimultaneous hazards. The performance of the variable friction cladding connection is also assessed and compared against different control cases. Results show that the motion-based design procedure yields a conservative design approach in meeting all of the motion requirements and that the variable friction cladding connection performs significantly well at mitigating vibrations. 
    more » « less
  5. The complex dynamics of vertically separated flows pose a significant challenge when it comes to assessing the wind loads on multi-level structures, demanding a nuanced understanding of the intricate interplay between atmospheric conditions and architectural designs. Previous studies and wind loading standards provide insufficient guidance for designing wind pressures on multi-level buildings. The behavior of wind around perpendicularly attached surfaces is not quite similar to that of individual flat roofs or walls. When a body is composed of several surfaces with right or oblique angles, the separated flow from surfaces and their interactions will cause complex flow patterns around each surface. A wind tunnel experimental study was carried out on bluff bodies with attached flat plates and other adjacent bluff bodies with different heights to examine the wind-induced pressures on such complex shapes. Mean and peak pressure coefficients were measured to determine the flow interaction patterns and location of localized peak pressures. The results were compared to the Tokyo Polytechnic University Aerodynamic Database of isolated low-rise buildings without eaves. The research findings indicated that there was a noteworthy disparity between the minimum and maximum values and locations of peak pressures on both the wall and roof surfaces of the models used in this study, as compared to the results obtained by the Tokyo Polytechnic University. Moreover, the study conceivably pointed to the difference between the peak negative and positive pressure coefficient locations with the ASCE 7-22 wind loading zones. The peak suction zones were affected by the combined flows at perpendicular faces, and as a result, different wind load zones were obtained dissimilar to those introduced by ASCE 7-22. Wind loading standards may need to be modified to account for the wind pressures on complex building structures with an emphasis on the location of the peak negative pressure zones.

     
    more » « less