skip to main content


Title: Dynamic monitoring and proactive fouling management in a pilot scale gas-sparged anaerobic membrane bioreactor
This study examines membrane performance data of a pilot-scale gas-sparged anaerobic membrane bioreactor (AnMBR) over its 472 day operational period and characterizes the foulant cake constituents through a membrane autopsy. The average permeability of 336 ± 81 LMH per bar during the first 40 days of operation decreased by 92% by the study's conclusion. While maintenance cleaning was effective initially, its ability to restore permeability decreased with time. Wasting bioreactor solids appeared to be effective in restoring permeability where chemical cleans were unable to. The restoration mechanism appears to be a decrease in colloidal material, measured by semi-soluble chemical oxygen demand (ssCOD), rather than bioreactor total solids concentration. This is further supported through the use of fluorometry during AnMBR operation, which showed an increase in tyrosine-like compounds during heavy fouling conditions, suggesting that proteinaceous materials have a large influence on fouling. This was corroborated during membrane autopsy using Fourier transform infrared spectroscopy (FTIR). FTIR, scanning electron microscopy with energy dispersive X-ray spectroscopy, and transmission electron microscopy were used to characterize inorganic scalants and predominantly found phosphate salts and calcium sulfate. Fundamentally characterizing foulants and introducing novel and dynamic monitoring parameters during AnMBR operation such as ssCOD and fluorometry can enable more targeted fouling control.  more » « less
Award ID(s):
1805631 1828571
NSF-PAR ID:
10211183
Author(s) / Creator(s):
; ; ; ;
Date Published:
Journal Name:
Environmental Science: Water Research & Technology
Volume:
6
Issue:
10
ISSN:
2053-1400
Page Range / eLocation ID:
2914 to 2925
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    Tangential flow filtration is advantageous for bioreactor clarification as the permeate stream could be introduced directly to the subsequent product capture step. However, membrane fouling coupled with high product rejection has limited its use. Here, the performance of a reverse asymmetric hollow fiber membrane where the more open pore structure faces the feed stream and the barrier layer faces the permeate stream has been investigated. The open surface contains pores up to 40 μm in diameter while the tighter barrier layer has an average pore size of 0.4 μm. Filtration of Chinese hamster ovary cell feed streams has been investigated under conditions that could be expected in fed batch operations. The performance of the reverse asymmetric membrane is compared to that of symmetric hollow fiber membranes with nominal pore sizes of 0.2 and 0.65 μm. Laser scanning confocal microscopy was used to observe the locations of particle entrapment. The throughput of the reverse asymmetric membrane is significantly greater than the symmetric membranes. The membrane stabilizes an internal high permeability cake that acts like a depth filter. This stabilized cake can remove particulate matter that would foul the barrier layer if it faced the feed stream. An empirical model has been developed to describe the variation of flux and transmembrane pressure drop during filtration using reverse asymmetric membranes. Our results suggest that using a reverse asymmetric membrane could avoid severe flux decline associated with fouling of the barrier layer during bioreactor clarification.

     
    more » « less
  2. Direct monitoring techniques of fouling in membrane-based filtration processes can be implemented as part of an effort to reduce the negative effects of membrane fouling. In particular, monitoring techniques with chemical characterization capability are crucial for the formulation of effective fouling prevention and mitigation strategies. In the present work, Raman spectroscopy was applied as an in-situ monitoring technique for calcium carbonate scaling on commercial reverse osmosis membranes. The bench-scale Raman monitoring system allowed for a qualitative chemical assay of the scaled membrane surface at sequential downstream and upstream axial positions. The time evolution of the downstream and upstream calcium carbonate Raman signal was evaluated with respect to computed values of local concentration at the membrane surface, revealing a statistically significant dependence (p < 0.001). The real-time Raman data were bolstered by results of post-mortem analysis (scanning electron microscopy, gravimetric measurements, and laser interferometry). The employed technique was capable of detecting crystals with characteristic lengths <50 μm. Preliminary evidence of polymorph detection was also presented with recommendations for improvements in the technique. 
    more » « less
  3. In this study, hydrophilic silica nanoparticles (Si NPs) were used to modify α-alumina tubular membranes to improve their performance in terms of flux, oil rejection, and anti-fouling properties. Our work focuses on enhancing membrane performance, particularly for difficult applications such as produced water treatment. The prepared membranes were applied for oil-in-water emulsion treatment. After coating hydrophilic Si NPs, the oil contact angle improved from 133.8° to 171.4°. To prevent Si NPs from leaching off the surface of α-alumina tubular membranes, polyvinyl alcohol was used to coat the membranes as a pre-treatment step before Si NP modification. After coating the membrane with Si NPs, the roughness of the membrane surface decreased, likely leading to less fouling. After coating Si NPs, Total Organic Carbon rejection increased from 93.1% for pristine α-alumina tubular membranes to 97.7% for silica-modified membranes because of hydrophilic improvements of the modified membranes. The Si NP coating improved the anti-fouling property of membranes with the flux recovery ratio increasing from 71.3% for pristine α-alumina tubular membranes to 85.9% for silica-modified membranes. Scanning Electron Microscopy, Energy- dispersive X-ray spectroscopy, oil contact angle, and Atomic Force Microscopy characterization tests were done. The tests showed successful Si NPs impregnation and altered wettability. 
    more » « less
  4. Abstract

    Alternating tangential flow filtration (ATF) has become one of the primary methods for cell retention and clarification in perfusion bioreactors. However, membrane fouling can cause product sieving losses that limit the performance of these systems. This study used scanning electron microscopy and energy dispersive X‐ray spectroscopy to identify the nature and location of foulants on 0.2 μm polyethersulfone hollow fiber membranes after use in industrial Chinese hamster ovary cell perfusion bioreactors for monoclonal antibody production. Membrane fouling was dominated by proteinaceous material, primarily host cell proteins along with some monoclonal antibody. Fouling occurred primarily on the lumen surface with much less protein trapped within the depth of the fiber. Protein deposition was also most pronounced near the inlet/exit of the hollow fibers, which are the regions with the greatest flux (and transmembrane pressure) during the cyclical operation of the ATF. These results provide important insights into the underlying phenomena governing the fouling behavior of ATF systems for continuous bioprocessing.

     
    more » « less
  5. Abstract

    Chinese hamster ovary (CHO) cells are among the most common cell lines used for therapeutic protein production. Membrane fouling during bioreactor harvesting is a major limitation for the downstream purification of therapeutic proteins. Host cell proteins (HCP) are the most challenging impurities during downstream purification processes. The present work focuses on identification of HCP foulants during CHO bioreactor harvesting using reverse asymmetrical commercial membrane BioOptimal™ MF‐SL. In order to investigate foulants and fouling behavior during cell clarification, for the first time a novel backwash process was developed to effectively elute almost all the HCP and DNA from the fouled membrane filter. The isoelectric points (pIs) and molecular weights (MWs) of major HCP in the bioreactor harvest and fouled on the membrane were successfully characterized using two‐dimensional gel electrophoresis (2D SDS‐PAGE). In addition, a total of 8 HCP were identified using matrix‐assisted laser desorption/ionization‐mass spectroscopy (MALDI‐MS). The majority of these HCP are enzymes or associated with exosomes, both of which can form submicron‐sized particles which could lead to the plugging of the filters.

     
    more » « less