Title: Quantifying the impacts of modeling uncertainties on the seismic drift demands and collapse risk of buildings with implications on seismic design checks
Summary

Robust estimation of collapse risk should consider the uncertainty in modeling of structures as well as variability in earthquake ground motions. In this paper, we illustrate incorporation of the uncertainty in structural model parameters in nonlinear dynamic analyses to probabilistically assess story drifts and collapse risk of buildings. Monte Carlo simulations with Latin hypercube sampling are performed on ductile and non‐ductile reinforced concrete building archetypes to quantify the influence of modeling uncertainties and how it is affected by the ductility and collapse modes of the structures. Inclusion of modeling uncertainty is shown to increase the mean annual frequency of collapse by approximately 1.8 times, as compared with analyses neglecting modeling uncertainty, for a high‐seismic site. Modeling uncertainty has a smaller effect on drift demands at levels usually considered in building codes; for the same buildings, modeling uncertainty increases the mean annual frequency of exceeding story drift ratios of 0.03 by 1.2 times. A novel method is introduced to relate drift demands at maximum considered earthquake intensities to collapse safety through a joint distribution of deformation demand and capacity. This framework enables linking seismic performance goals specified in building codes to drift limits and other acceptance criteria. The distributions of drift demand at maximum considered earthquake and capacity of selected archetype structures enable comparisons with the proposed seismic criteria for the next edition (2016) of ASCE 7. Subject to the scope of our study, the proposed drift limits are found to be unconservative, relative to the target collapse safety in ASCE 7. Copyright © 2016 John Wiley & Sons, Ltd.

 
more » « less
NSF-PAR ID:
10214499
Author(s) / Creator(s):
 ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Earthquake Engineering & Structural Dynamics
Volume:
45
Issue:
10
ISSN:
0098-8847
Page Range / eLocation ID:
p. 1661-1683
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Studies of recorded ground motions and simulations have shown that deep sedimentary basins can greatly increase the damage expected during earthquakes. Unlike past earthquake design provisions, future ones are likely to consider basin effects, but the consequences of accounting for these effects are uncertain. This article quantifies the impacts of basin amplification on the collapse risk of 4- to 24-story reinforced concrete wall building archetypes in the uncoupled direction. These buildings were designed for the seismic hazard level in Seattle according to the ASCE 7-16 design provisions, which neglect basin effects. For ground motion map frameworks that do consider basin effects (2018 USGS National Seismic Hazard Model), the average collapse risk for these structures would be 2.1% in 50 years, which exceeds the target value of 1%. It is shown that this 1% target could be achieved by: (1) increasing the design forces by 25%, (2) decreasing the drift limits from 2.0% to 1.25%, or (3) increasing the median drift capacity of the gravity systems to exceed 9%. The implications for these design changes are quantified in terms of the cross-sectional area of the walls, longitudinal reinforcement, and usable floor space. It is also shown that the collapse risk increases to 2.8% when the results of physics-based ground motion simulations are used for the large-magnitude Cascadia subduction interface earthquake contribution to the hazard. In this case, it is necessary to combine large changes in the drift capacities, design forces, and/or drift limits to meet the collapse risk target.

     
    more » « less
  2. null (Ed.)
    Loss of operation or devastating damage to buildings and industrial structures, as well as equipment housed in them, has been observed due to earthquake-induced vibrations. A common source of operational downtime is due to the performance reduction of vital equipment, which are sensitive to the total transmitted acceleration. A well-known method of protecting such equipment is seismic isolation of the equipment itself (or a group of equipment), as opposed to the entire structure due to the lower cost of implementation. The first objective of this dissertation is assessing a rolling isolation system (RIS) based on existing design guidelines for telecommunications equipment. A discrepancy is observed between the required response spectrum (RRS) and the one and only accelerogram recommended in the guideline. Several filters are developed to generate synthetic accelerograms that are compatible with the RRS. The generated accelerograms are used for probabilistic assessment of a RIS that is acceptable per the guideline. This assessment reveals large failure probability due to displacement demands in excess of the displacement capacity of the RIS. When the displacement demands on an isolation system are in excess of its capacity, impacts result in spikes in transmitted acceleration. Therefore, the second objective of this dissertation is to design impact prevention/mitigation mechanisms. A dual-mode system is proposed where the behavior changes when the displacement exceeds a predefined threshold. A new piecewise optimal control approach is developed and applied to find the best possible mechanism for the region beyond the threshold. By utilizing the designed curves obtained from the proposed optimal control procedure, a Kelvin-Voigt device is tuned for illustrative purposes. On the other hand, the preference for protecting equipment decreases as the earthquake intensity increases. In extreme seismic loading, the response mitigation of the primary structure (i.e., life safety and collapse prevention) is of greater concern than protecting isolated equipment. Therefore, the third objective of this dissertation is to develop an innovative dual-mode system that can behave as equipment isolation under low to moderate seismic loading and passively transition to behave as a vibration absorber for the primary structure under extreme seismic loading. To reduce the computational cost of simulating a large linear elastic structure with nonlinear attachments (i.e., equipment isolation with cubic hardening nonlinearity), a reduced order modeling method is introduced that can capture the behavior of such nonlinear coupled systems. The method is applied to study the feasibility of dual-mode vibration isolation/absorber. To this end, nonlinear transmissibility curves for the roof displacement and isolated mass total acceleration are developed from the steady-state responses of dual-mode systems using the harmonic balanced method. The final objective of this dissertation is to extend the reduced order modeling method developed for linear elastic structure with nonlinear attachment to inelastic structures (without attachments). The new inelastic model condensation (IMC) method uses the modal properties of the full structural model (in the elastic range) to construct a linear reduced order model in conjunction with a hysteresis model to capture the hysteretic inter-story restoring forces. The parameters of these hysteretic forces are easily tuned, in order to fit the inelastic behavior of the condensed structure to that of the full model under a variety of simple loading scenarios. The fidelity of structural models condensed in this way is demonstrated via simulation for different ground motion intensities on three different building structures with various heights. The simplicity, accuracy, and efficiency of this approach could significantly alleviate the computational burden of performance-based earthquake engineering. 
    more » « less
  3. null (Ed.)
    Nonlinear time history analyses were conducted for 5-story and 12-story prototype buildings that used post-tensioned cross-laminated timber rocking walls coupled with U-shaped flexural plates (UFPs) as the lateral force resisting system. The building models were subjected to 22 far-field and 28 near-fault ground motions, with and without directivity effects, scaled to the design earthquake and maximum considered earthquake for Seattle, with ASCE Site Class D. The buildings were designed to performance objectives that limited structural damage to crushing at the wall toes and nonlinear deformation in the UFPs, while ensuring code-based interstory drift requirements were satisfied and the post-tensioned rods remained linear. The walls of the 12-story building had a second rocking joint at midheight to reduce flexural demands in the lower stories and interstory drift in the upper stories. The interstory drift, in-plane wall shear and overturning moment, UFP deformation, and extent of wall toe crushing is summarized for each building. Near-fault ground motions with directivity effects resulted in the largest demands for the 5-story building, while the midheight rocking joint diminished the influence of ground motion directivity effects in the 12-story building. Results for both buildings confirmed that UFPs located higher from the base of the walls dissipated more energy compared to UFPs closer to the base. 
    more » « less
  4. Summary

    The objective of this paper is to present incremental dynamic analysis (IDA) and seismic performance evaluation results for a two‐story cold‐formed steel (CFS)–framed building. The archetype building was designed to current U.S. standards and then subjected to full‐scale shake table tests under the U.S. National Science Foundation Network for Earthquake Engineering Simulation (NEES) program. Test results showed that the building's stiffness and capacity were considerably higher than expected and the building suffered only nonstructural damage even at excitations in excess of Maximum Considered Earthquake levels for a high seismic zone. For the archetype building, three‐dimensional finite element models at different modeling fidelity levels were created using OpenSees. The models are subjected to IDA using the far‐field ground motion records prescribed in Federal Emergency Management Agency (FEMA) P695. Seismic performance quantification following the FEMA P695 procedure shows that if the modeling fidelity only follows the state‐of‐the‐practice, ie, only includes shear walls, unsafe collapse margin ratios are predicted. State‐of‐the‐art models that account for participation from CFS gravity walls and architectural sheathing have overall performance that are consistent with testing, and IDA results indicate acceptable collapse margin ratios, predicated primarily on large system overstrength. Neglecting the lateral force resistance of the gravity system and nonstructural components, as done in current design, renders a safe design in the studied archetype, but largely divorced from actual system behavior. The modeling protocols established here provide a means to analyze a future suite of CFS‐framed archetype buildings for developing further insight on the seismic response modification coefficients for CFS‐framed buildings.

     
    more » « less
  5. An accurate quantification of the displacement capacity of a reinforced masonry shear-wall system is of critical importance to seismic design because it has a direct implication on the seismic force modification factor, which is the R factor in ASCE 7. In spite of the shear capacity design requirement in TMS 402, special reinforced masonry walls within a building system could still develop shear-dominated behavior, which is perceived to be far more brittle than flexural behavior. These walls have a low shear-span ratio either because of the wall geometry (i.e., a low height-to-length ratio) or the coupling forces introduced by the horizontal diaphragms, which are often ignored in design. Although shear-dominated walls appeared to be very brittle in quasi-static tests conducted on single planar wall segments, reinforced masonry structures survived major ground shaking well in past earthquakes. This could be partly attributed to the beneficial influence of wall flanges as well as the over-strength of the system. Flanged walls are common in masonry buildings, but their behavior is not well understood because of the lack of laboratory test data. Furthermore, other walls or columns that are present in the structural system to carry gravity loads could enhance the lateral resistance of the shear walls and the displacement capacity of the system by providing axial restraints as well as alternative load paths for gravity loads. A research project is being carried out with shake-table tests to investigate the displacement capacity of shear-dominated reinforced masonry wall systems. This paper presents results of the first shake-table test conducted in this project on a full-scale single-story coupled T-wall system. The structure was tested to a drift ratio exceeding 15% without collapse. 
    more » « less