Title: Photoacoustic Imaging as a Tool for Assessing Hair Follicular Organization
Follicular unit extraction (FUE) and follicular unit transplantation (FUT) account for 99% of hair transplant procedures. In both cases, it is important for clinicians to characterize follicle density for treatment planning and evaluation. The existing gold-standard is photographic examination. However, this approach is insensitive to subdermal hair and cannot identify follicle orientation. Here, we introduce a fast and non-invasive imaging technique to measure follicle density and angles across regions of varying density. We first showed that hair is a significant source of photoacoustic signal. We then selected regions of low, medium, and high follicle density and showed that photoacoustic imaging can measure the density of follicles even when they are not visible by eye. We performed handheld imaging by sweeping the transducer across the imaging area to generate 3D images via maximum intensity projection. Background signal from the dermis was removed using a skin tracing method. Measurement of follicle density using photoacoustic imaging was highly correlated with photographic determination (R2 = 0.96). Finally, we measured subdermal follicular angles—a key parameter influencing transection rates in FUE.  more » « less
Award ID(s):
1842387
PAR ID:
10222817
Author(s) / Creator(s):
; ; ;
Date Published:
Journal Name:
Sensors
Volume:
20
Issue:
20
ISSN:
1424-8220
Page Range / eLocation ID:
5848
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract Capitalizing on the photoacoustic effect, we developed a new fingerprint sensing system that can reveal both fingerprints and underlying vascular structures at a high spatial resolution. Our system is built on a 15 MHz linear transducer array, a research ultrasound system, and a 532-nm pulsed laser. A 3D image was obtained by scanning the linear array over the fingertip. The acquired fingerprint images strongly agreed with the images acquired from ultrasound. Additional experiments were also conducted to investigate the effect of acoustic coupling. We discovered that high-quality fingerprint and vessel images can be acquired from both wet and dry fingers using our photoacoustic system. The reduced subdermal features in dry coupling can be enhanced through post-processing. Compared to existing fingerprint scanners, the photoacoustic approach provides a higher quality 3D image of the fingerprint, as well as unique subdermal vasculature structures, making the system almost impossible to counterfeit. 
    more » « less
  2. Abstract Sterilization of skin prior to surgery is challenged by the reservoir of bacteria that resides in hair follicles. Atmospheric pressure plasma jets (APPJs) have been proposed as a method to treat and deactivate these bacteria as atmospheric plasmas are able to penetrate into structures and crevices with dimensions similar to those found in hair follicles. In this paper, we discuss results from a computational investigation of an APPJ sustained in helium flowing into ambient air, and incident onto a layered dielectric similar to human skin in which there are idealized hair follicles. We found that, depending on the location of the follicle, the bulk ionization wave (IW) incident onto the skin, or the surface IW on the skin, are able to launch IWs into the follicle. The uniformity of treatment of the follicle depends on the location of thefirst entryof the plasma into the follicle on the top of the skin. Typically, only one side of the follicle is treated on for a given plasma pulse, with uniform treatment resulting from rastering the plasma jet across the follicle over many pulses. Plasma treatment of the follicle is sensitive to the angle of the follicle with respect to the skin, width of the follicle pocket, conductivity of the dermis and thickness of the underlying subcutaneous fat layer, the latter due to the change in capacitance of the tissue. 
    more » « less
  3. The receive sensitivity of lead zirconate titanate (PZT) piezoelectric micromachined ultrasound transducers (PMUTs) was improved by applying a DC bias during operation. The PMUT receive sensitivity is governed by the voltage piezoelectric coefficient, h31,f. With applied DC biases (up to 15 V) on a 2 μm PbZr0.52Ti0.48O3 film, e31,f increased 1.6 times, permittivity decreased by a factor of 0.6, and the voltage coefficient increased by ~2.5 times. For released PMUT devices, the ultrasound receive sensitivity improved by 2.5 times and the photoacoustic signal improved 1.9 times with 15 V applied DC bias. B-mode photoacoustic imaging experiments showed that with DC bias, the PMUT received clearer photoacoustic signals from pencil leads at 4.3 cm, compared to 3.7 cm without DC bias. 
    more » « less
  4. Most reconstruction algorithms for photoacoustic imaging assume that the pressure field is measured by ultrasound sensors placed on a detection surface. However, such sensors do not measure pressure exactly due to their non-uniform directional and frequency responses, and resolution limitations. This is the case for piezoelectric sensors that are commonly employed for photoacoustic imaging. In this paper, using the method of matched asymptotic expansions and the basic constitutive relations for piezoelectricity, we propose a simple mathematical model for piezoelectric transducers. The approach simultaneously models how the pressure waves induce the piezoelectric measurements and how the presence of the sensors affects the pressure waves. Using this model, we analyze whether the data gathered by piezoelectric sensors leads to the mathematical solvability of the photoacoustic imaging problem. We conclude that this imaging problem is well-posed in certain normed spaces and under a geometric assumption. We also propose an iterative reconstruction algorithm that incorporates the model for piezoelectric measurements. A numerical implementation of the reconstruction algorithm is presented. 
    more » « less
  5. Abstract Bat wing membranes are composed of specialized skin that is covered with small sensory hairs which are likely mechanosensory and have been suggested to help bats sense airflow during flight. These sensory hairs have to date been studied in only a few of the more than 1,400 bat species around the world. Little is known about the diversity of the sensory hair network across the bat phylogeny. In this study, we use high‐resolution photomicrographs of preserved bat wings from 17 species in 12 families to characterize the distribution of sensory hairs along the wing and among species. We identify general patterns of sensory hair distribution across species, including the apparent relationships of sensory hairs to intramembranous wing muscles, the network of connective tissues in the wing membrane, and the bones of the forelimb. We also describe distinctive clustering of these sensory structures in some species. We also quantified sensory hair density in several regions of interest in the propatagium, plagiopatagium, and dactylopagatia, finding that sensory hair density was higher proximally than distally. This examination of the anatomical organization of the sensory hair network in a comparative context provides a framework for existing research on sensory hair function and highlights avenues for further research. 
    more » « less