Title: A Review on Low-Cost Microwave Doppler Radar Systems for Structural Health Monitoring
Portable, low-cost, microwave radars have attracted researchers’ attention for being an alternative noncontact solution for structural condition monitoring. In addition, by leveraging their capability of providing the target velocity information, the radar-based remote monitoring of complex rotating structures can also be accomplished. Modern radar systems are compact, able to be easily integrated in sensor networks, and can deliver high accuracy measurements. This paper reviews the recent technical advances in low-cost Doppler radar systems for phase-demodulated displacement measurements and time-Doppler analysis for structural health information, including digital signal processing and emerging applications related to radar sensor networks.  more » « less
Award ID(s):
1808613 2030094
PAR ID:
10230641
Author(s) / Creator(s):
;
Date Published:
Journal Name:
Sensors
Volume:
21
Issue:
8
ISSN:
1424-8220
Page Range / eLocation ID:
2612
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Activity recognition has applications in a variety of human-in-the-loop settings such as smart home health monitoring, green building energy and occupancy management, intelligent transportation, and participatory sensing. While fine-grained activity recognition systems and approaches help enable a multitude of novel applications, discovering them with non-intrusive ambient sensor systems pose challenging design, as well as data processing, mining, and activity recognition issues. In this paper, we develop a low-cost heterogeneous Radar based Activity Monitoring (RAM) system for recognizing fine-grained activities. We exploit the feasibility of using an array of heterogeneous micro-doppler radars to recognize low-level activities. We prototype a short-range and a long-range radar system and evaluate the feasibility of using the system for fine-grained activity recognition. In our evaluation, using real data traces, we show that our system can detect fine-grained user activities with 92.84% accuracy. 
    more » « less
  2. This study examines the use of a Doppler radar occupancy sensor to assess thermal adaptation. Current heating, ventilation, and air-conditioning (HVAC) systems are important for the productivity of employees and the healing of patients; however, their control systems are typically limited to a narrow temperature range, which is usually not comfortable for most occupants. Occupant vital signs can be used to assess thermal comfort, due to the role cardiovascular regulation plays in heat dissipation. This research aims to correlate physiological and thermal adaptation with the goal of optimizing HVAC system operation. A Doppler radar occupancy sensor was used to measure the physiological parameters of ten human subjects under two temperature conditions, and thermal comfort surveys were used to record thermal sensation. The results demonstrate that the Doppler radar occupancy sensor could not only detect heart rate changes due to a significant environmental temperature difference but also detect subtle changes in heart rate during thermal adaptation that were not captured by the surveys. 
    more » « less
  3. Accurate continuous measurement of respiratory displacement using continuous wave Doppler radar requires rigorous management of dc offset which changes when a subject changes distance from the radar measurement system. Effective measurement, therefore, requires robust dynamic calibration which can recognize and compensate for changes in the nominal position of a subject. In this paper, a respiratory displacement measurement algorithm is proposed which can differentiate between sedentary and non-sedentary conditions and continuously adapt to provide long-term monitoring of a subject’s sedentary respiration. Arctangent demodulation is an effective means of quantifying continuous displacement using a quadrature Doppler radar, yet it depends on accurate identification of dc offset and dc information contributions in the radar I-Q arc with the subject in a particular position. The dynamic calibration method proposed here is demonstrated to differentiate between sedentary and non-sedentary conditions for six subjects to produce accurate sedentary respiration measurements even when the subject arbitrarily changes position, once the appropriate thresholds are established for the measurement environment. 
    more » « less
  4. Respiration rate and heart rate variability (HRV) due to respiratory sinus arrhythmia (RSA) are physiological measurements that can offer useful diagnostics for a variety of medical conditions. This study uses a wrist-worn wearable development platform from Maxim Integrated and Doppler radar sensor developed by Adnoviv, Inc. to non-invasively measure these physiological signals. Six datasets are recorded comprising of five different individuals in varying physical environments breathing at different respiration rates. First, respiration rates are extracted from photoplethysmography (PPG) and accelerometer data and compared to Doppler radar. The average maximum and minimum difference between Doppler radar extracted RR and PPG, HRV RSA, and accelerometer extracted RR is 0.342 b/m and 0.171 b/m, respectively. Then, waveforms for Doppler radar, PPG, and HRV RSA signals are plotted in time domain and an analysis discusses the physical phenomena associated with the phase alignment of the signals. 
    more » « less
  5. Low-cost sensors enable finer-scale spatiotemporal measurements within the existing methane (CH 4 ) monitoring infrastructure and could help cities mitigate CH 4 emissions to meet their climate goals. While initial studies of low-cost CH 4 sensors have shown potential for effective CH 4 measurement at ambient concentrations, sensor deployment remains limited due to questions about interferences and calibration across environments and seasons. This study evaluates sensor performance across seasons with specific attention paid to the sensor's understudied carbon monoxide (CO) interferences and environmental dependencies through long-term ambient co-location in an urban environment. The sensor was first evaluated in a laboratory using chamber calibration and co-location experiments, and then in the field through two 8 week co-locations with a reference CH 4 instrument. In the laboratory, the sensor was sensitive to CH 4 concentrations below ambient background concentrations. Different sensor units responded similarly to changing CH 4 , CO, temperature, and humidity conditions but required individual calibrations to account for differences in sensor response factors. When deployed in-field, co-located with a reference instrument near Baltimore, MD, the sensor captured diurnal trends in hourly CH 4 concentration after corrections for temperature, absolute humidity, CO concentration, and hour of day. Variable performance was observed across seasons with the sensor performing well ( R 2 = 0.65; percent bias 3.12%; RMSE 0.10 ppm) in the winter validation period and less accurately ( R 2 = 0.12; percent bias 3.01%; RMSE 0.08 ppm) in the summer validation period where there was less dynamic range in CH 4 concentrations. The results highlight the utility of sensor deployment in more variable ambient CH 4 conditions and demonstrate the importance of accounting for temperature and humidity dependencies as well as co-located CO concentrations with low-cost CH 4 measurements. We show this can be addressed via Multiple Linear Regression (MLR) models accounting for key covariates to enable urban measurements in areas with CH 4 enhancement. Together with individualized calibration prior to deployment, the sensor shows promise for use in low-cost sensor networks and represents a valuable supplement to existing monitoring strategies to identify CH 4 hotspots. 
    more » « less