skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: In situ measurement of the isoplanatic patch for imaging through intact bone
Abstract Wavefront‐shaping (WS) enables imaging through scattering tissues like bone, which is important for neuroscience and bone‐regeneration research. WS corrects for the optical aberrations at a given depth and field‐of‐view (FOV) within the sample; the extent of the validity of which is limited to a region known as the isoplanatic patch (IP). Knowing this parameter helps to estimate the number of corrections needed for WS imaging over a given FOV. In this paper, we first present direct transmissive measurement of murine skull IP using digital optical phase conjugation based focusing. Second, we extend our previously reported phase accumulation ray tracing (PART) method to provide in‐situin‐silicoestimation of IP, called correlative PART (cPART). Our results show an IP range of 1 to 3 μm for mice within an age range of 8 to 14 days old and 1.00 ± 0.25 μm in a 12‐week old adult skull. Consistency between the two measurement approaches indicates that cPART can be used to approximate the IP before a WS experiment, which can be used to calculate the number of corrections required within a given field of view.  more » « less
Award ID(s):
1706916
PAR ID:
10238346
Author(s) / Creator(s):
 ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Journal of Biophotonics
Volume:
14
Issue:
1
ISSN:
1864-063X
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Head-mounted miniaturized two-photon microscopes are powerful tools to record neural activity with cellular resolution deep in the mouse brain during unrestrained, free-moving behavior. Two-photon microscopy, however, is traditionally limited in imaging frame rate due to the necessity of raster scanning the laser excitation spot over a large field-of-view (FOV). Here, we present two multiplexed miniature two-photon microscopes (M-MINI2Ps) to increase the imaging frame rate while preserving the spatial resolution. Two different FOVs are imaged simultaneously and then demixed temporally or computationally. We demonstrate large-scale (500×500 µm2 FOV) multiplane calcium imaging in visual cortex and prefrontal cortex in freely moving mice during spontaneous exploration, social behavior, and auditory stimulus. Furthermore, the increased speed of M-MINI2Ps also enables two-photon voltage imaging at 400 Hz over a 380×150 µm2 FOV in freely moving mice. M-MINI2Ps have compact footprints and are compatible with the open-source MINI2P. M-MINI2Ps, together with their design principles, allow the capture of faster physiological dynamics and population recordings over a greater volume than currently possible in freely moving mice, and will be a powerful tool in systems neuroscience. # Data for: Multiplexed miniaturized two-photon microscopy (M-MINI2Ps) Dataset DOI: [10.5061/dryad.kd51c5bkp](10.5061/dryad.kd51c5bkp) ## Description of the data and file structure Calcium and Voltage imaging datasets from Multiplexed Miniaturized Two-Photon Microscopy (M-MINI2P) ### Files and variables #### File: TM_MINI2P_Voltage_Cranial_VisualCortex.zip **Description:** Voltage imaging dataset acquired in mouse primary visual cortex (V1) using the TM-MINI2P system through a cranial window preparation. This .zip file contains two Tif files, corresponding to the top field of view (FOV) and the bottom field of view (FOV) of the demultiplexed recordings. #### File: TM_MINI2P_Calcium_GRIN_PFC_Auditory_Free_vs_Headfix.zip **Description:** Volumetric calcium imaging dataset from mouse prefrontal cortex (PFC) using the TM-MINI2P system with a GRIN lens implant, comparing neural responses during sound stimulation versus quiet periods, under both freely moving and head-fixed conditions. This .zip file contains 12 Tif files: top and bottom fields of view (FOVs) of the multiplexed recordings at three imaging depths (100 μm, 155 μm, and 240 μm from the end of the implanted GRIN lens), with six files from freely moving conditions and six files from head-fixed conditions. #### File: CM_MINI2P_Calcium_Cranial_VisualCortex_SocialBehavior.zip **Description:** Calcium imaging dataset from mouse primary visual cortex (V1) using the CM-MINI2P system through a cranial window, recorded during social interaction and isolated conditions. This .zip file contains 6 Tif files: multiplexed recordings from the top and bottom fields of view (FOVs), and single-FOV recordings at two imaging depths (170 µm and 250 µm). #### File: TM_MINI2P_Calcium_Cranial_VisualCortex.zip **Description:** Multi-depth calcium imaging dataset from mouse primary visual cortex (V1) using the TM-MINI2P system through a cranial window during spontaneous exploration. This .zip file contains 6 Tif files: demultiplexed recordings from two fields of view (FOV1 and FOV2) at three imaging depths (110 µm, 170 µm, and 230 µm). ## Code/software All datasets are in .tiff format and ImageJ can be used for visualization. Analysis of calcium imaging data and voltage imaging data were analyzed using CaImAn and Volpy, respectively, which are open-source packages available at [https://github.com/flatironinstitute/CaImAn](https://github.com/flatironinstitute/CaImAn). 
    more » « less
  2. Abstract Epidural anesthesia helps manage pain during different surgeries. Nonetheless, the precise placement of the epidural needle remains a challenge. In this study, we developed a probe based on polarization‐sensitive optical coherence tomography (PS‐OCT) to enhance the epidural anesthesia needle placement. The probe was tested on six porcine spinal samples. The multimodal imaging guidance used the OCT intensity mode and three distinct PS‐OCT modes: (1) phase retardation, (2) optic axis, and (3) degree of polarization uniformity (DOPU). Each mode enabled the classification of different epidural tissues through distinct imaging characteristics. To further streamline the tissue recognition procedure, convolutional neural network (CNN) were used to autonomously identify the tissue types within the probe's field of view. ResNet50 models were developed for all four imaging modes. DOPU imaging was found to provide the highest cross‐testing accuracy of 91.53%. These results showed the improved precision by PS‐OCT in guiding epidural anesthesia needle placement. 
    more » « less
  3. Near infrared and infrared multi-photon imaging through or inside bone is an emerging field that promises to help answer many biological questions that require minimally invasive intravital imaging. Neuroscience researchers especially have begun to take advantage of long wavelength imaging to overcome multiple scattering and image deep inside the brain through intact or partially intact bone. Since the murine model is used in many biological experiments, here we investigate the optical aberrations caused by mouse cranial bone, and their effects on light propagation. We previously developed a ray tracing model that uses second harmonic generation in collagen fibers of bone to estimate the refractive index structure of the sample. This technique is able to rapidly provide initial information for a closed loop adaptive optics system. However, the ray tracing method does not account for refraction or scattering. Here, we extend our work to investigate the wavefront aberrations in bone using a full electromagnetic model. We used Finite-Difference Time-Domain modeling of light propagation in refractive index bone datasets acquired with second harmonic generation imaging. In this paper we show modeled wavefront phase from different originating points across the field of view. 
    more » « less
  4. This Letter reports a new, to the best of our knowledge, high-frequency surface-micromachined optical ultrasound transducer (HF-SMOUT) array for micro photoacoustic computed tomography (µPACT). An 11 × 11 mm22D array of 220 × 220 elements (35 µm in diameter) is designed, fabricated, and characterized. The optical resonance wavelength (ORW) of ≥90% of the elements falls within a 6-nm range. The acoustic center frequency and bandwidth of the elements are ∼14 MHz and ∼18 MHz (129%), respectively. The noise equivalent pressure (NEP) is 161 Pa (or 18 mPa/Hz) within a measurement bandwidth of 5–75 MHz. The standard deviation of the ORW drift is 0.45 nm and 0.93 nm within 25°C−55°C, respectively, and during a seven-day continuous water immersion. PACT experiments are conducted to evaluate the imaging performances of the HF-SMOUT array. The spatial resolution is estimated as 90 µm (axial) and 250–750 µm (lateral) within a 10 × 10 mm2field of view (FoV) and the imaging depth of 16 mm. A 3D PA image of a knotted black hair target is also successfully acquired. These results demonstrate the feasibility of using the HF-SMOUT array for µPACT applications. 
    more » « less
  5. Marshall, Heather K; Spyromilio, Jason; Usuda, Tomonori (Ed.)
    We present the optical design for Cryoscope, a 0.26 m aperture telescope that is a f/2 objective operating over the photometric K band (1.99 to 2.55 μm) with diffraction limited imaging. It has a 16 deg2 FoV with a 7.1′′/pix plate scale on a 2048×2048 18 μm/pixel Teledyne H2RG detector array. The objective is a catadioptric design incorporating two thin fused silica meniscus lenses near the entrance aperture, a spherical primary mirror, and a doublet immediately in front of the detector to flatten the image surface. The design solution is capable of delivering diffraction limited images over a 10° field diameter at f/1.25 in the NIR. The use of fused silica for the first two lens elements allows the design to be used for a broad range of applications from the vacuum ultraviolet to thermal IR with only re-optimization of the field flattening doublet. In the VUV (185 to 300 nm) the design is no longer diffraction limited, but can still be made to be pixel limited with detector arrays having pixels as small as 10 μm. The design provides a compact, wide field, and fast objective that can scale to a 1 m-class telescope and offers several benefits over a classical Schmidt telescope. The convex fused silica meniscus lens is strong enough to serve as a vacuum window allowing the entire optical path to be cryogenically cooled to maintain low thermal emission while delivering two orders of magnitude larger field of view than previous ground-based designs for the thermal infrared. 
    more » « less