skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Detection of a multi‐disease biomarker in saliva with graphene field effect transistors
Abstract Human carbonic anhydrase 1 (CA1) has been suggested as a biomarker for identification of several diseases including cancers, pancreatitis, diabetes and Sjogren's syndrome. However, the lack of a rapid, cheap, accurate and easy‐to‐use quantification technique has prevented widespread utilization of CA1 for practical clinical applications. To this end, we present a label‐free electronic biosensor for detection of CA1 utilizing highly sensitive graphene field effect transistors (G‐FETs) as a transducer and specific RNA aptamers as a probe. The binding of CA1 with aptamers resulted in a positive shift in Dirac voltageVDof the G‐FETs, the magnitude of which depended on target concentration. These aptameric G‐FET biosensors showed the binding affinity (KD) of ~2.3 ng/ml (70 pM), which is four orders lower than that reported using a gel shift assay. This lower value ofKDenabled us to achieve a detection range (10 pg/ml –100 ng/ml) which is well in line with the clinically relevant range. These highly sensitive devices allowed us to further prove their clinical relevance by successfully detecting the presence of CA1 in human saliva samples. Utilization of this label‐free biosensor could facilitate the early‐stage identification of various diseases associated with changes in concentration of CAs.  more » « less
Award ID(s):
2003343
PAR ID:
10240583
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
MEDICAL DEVICES & SENSORS
Volume:
3
Issue:
6
ISSN:
2573-802X
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Lab-on-a-chip technology offers an ideal platform for low-cost, reliable, and easy-to-use diagnostics of key biomarkers needed for early screening of diseases and other health concerns. In this work, a graphene field-effect transistor (GFET) functionalized with target-binding aptamers is used as a biosensor for the detection of thrombin protein biomarker. Furthermore, this GFET is integrated with a microfluidic device for enhanced sensing performances in terms of detection limit, sensitivity, and continuous monitoring. Under this platform, a picomolar limit of detection was achieved for measuring thrombin; in our experiment measured as low as 2.6 pM. FTIR, Raman and UV-Vis spectroscopy measurements were performed to confirm the device functionalization steps. Based on the concentration-dependent calibration curve, a dissociation constant of K D = 375.8 pM was obtained. Continuous real-time measurements were also conducted under a constant gate voltage ( V GS ) to observe the transient response of the sensor when analyte was introduced to the device. The target selectivity of the sensor platform was evaluated and confirmed by challenging the GFET biosensor with various concentrations of lysozyme protein. The results suggest that this device technology has the potential to be used as a general diagnostic platform for measuring clinically relevant biomarkers for point-of-care applications. 
    more » « less
  2. In this research, a novel electrochemical biosensor is proposed based on inducing graphene formation on polyimide substrate via laser engraving. Graphene polyaniline (G-PANI) conductive ink was synthesized by planetary mixing and applied to the working zone of the developed sensor to effectively enhance the electrical signals. The laser-induced graphene (LIG) sensor was used to detect alpha-fetoprotein (AFP) and 17β-Estradiol (E2) in the phosphate buffer saline (PBS) buffer and human serum. The electrochemical performance of the biosensor in determining these biomarkers was investigated by differential pulse voltammetry (DPV) and chronoamperometry (CA). In a buffer environment, alpha-fetoprotein (AFP) and 17β-Estradiol detection range were 4–400 ng/mL and 20–400 pg/mL respectively. The experimental results showed a limit of detection (LOD) of 1.15 ng/mL and 0.96 pg/mL for AFP and estrogen, respectively, with an excellent linear range (R2 = 0.98 and 0.99). In addition, the designed sensor was able to detect these two types of biomarkers in human serum successfully. The proposed sensor exhibited excellent reproducibility, repeatability, and good stability (relative standard deviation, RSD = 0.96%, 1.12%, 2.92%, respectively). The electrochemical biosensor proposed herein is easy to prepare and can be successfully used for low-cost, rapid detection of AFP and E2. This approach provides a promising platform for clinical detection and is advantageous to healthcare applications. 
    more » « less
  3. Abstract Staphylococcus aureus(S. aureus), a common foodborne pathogen, poses significant public health challenges due to its association with various infectious diseases. A key player in its pathogenicity, which is the IsdA protein, is an essential virulence factor inS. aureusinfections. In this work, we present an integrated in‐silico and experimental approach using MD simulations and surface plasmon resonance (SPR)‐based aptasensing measurements to investigateS. aureusbiorecognition via IsdA surface protein binding. SPR, a powerful real‐time and label‐free technique, was utilized to characterize interaction dynamics between the aptamer and IsdA protein, and MD simulations was used to characterize the stable and dynamic binding regions. By characterizing and optimizing pivotal parameters such as aptamer concentration and buffer conditions, we determined the aptamer's binding performance. Under optimal conditions of pH 7.4 and 150 mM NaCl concentration, the kinetic parameters were determined;ka = 3.789 × 104/Ms,kd = 1.798 × 103/s, andKD = 4.745 × 10−8 M. The simulations revealed regions of interest in the IsdA‐aptamer complex. Region I, which includes interactions between amino acid residues H106 and R107 and nucleotide residues 9G, 10U, 11G and 12U of the aptamer, had the strongest interaction, based on ΔG and B‐factor values, and hence contributed the most to the stability of the interaction. Region II, which covers residue 37A reflects the dynamic nature of the interaction due to frequent contacts. The approach presents a rigorous characterization of aptamer‐IsdA binding behavior, supporting the potential application of the IsdA‐binding aptamer system forS. aureusbiosensing. 
    more » « less
  4. Abstract Sensitive detection of pathogens is crucial for early disease diagnosis and quarantine, which is of tremendous need in controlling severe and fatal illness epidemics such as of Ebola virus (EBOV) disease. Serology assays can detect EBOV‐specific antigens and antibodies cost‐effectively without sophisticated equipment; however, they are less sensitive than reverse transcriptase polymerase chain reaction (RT‐PCR) tests. Herein, a 3D plasmonic nanoantenna assay sensor is developed as an on‐chip immunoassay platform for ultrasensitive detection of Ebola virus (EBOV) antigens. The EBOV sensor exhibits substantial fluorescence intensity enhancement in immunoassays compared to flat gold substrate. The nanoantenna‐based biosensor successfully detects EBOV soluble glycoprotein (sGP) in human plasma down to 220 fg mL−1, a significant 240 000‐fold sensitivity improvement compared to the 53 ng mL−1EBOV antigen detection limit of the existing rapid EBOV immunoassay. In a mock clinical trial, the sensor detects sGP‐spiked human plasma samples at two times the limit of detection with 95.8% sensitivity. The results combined highlight the nanosensor's extraordinary capability of detecting EBOV antigen at ultralow concentration compared to existing immunoassay methods. It is a promising next‐generation bioassay platform for early‐stage disease diagnosis and pathogen detection for both public health and national security applications. 
    more » « less
  5. null (Ed.)
    Aptamers are oligonucleotides or peptides that are selected from a pool of random sequences that exhibit high affinity toward a specific biomolecular species of interest. Therefore, they are ideal for use as recognition elements and ligands for binding to the target. In recent years, aptamers have gained a great deal of attention in the field of biosensing as the next-generation target receptors that could potentially replace the functions of antibodies. Consequently, it is increasingly becoming popular to integrate aptamers into a variety of sensing platforms to enhance specificity and selectivity in analyte detection. Simultaneously, as the fields of lab-on-a-chip (LOC) technology, point-of-care (POC) diagnostics, and personal medicine become topics of great interest, integration of such aptamer-based sensors with LOC devices are showing promising results as evidenced by the recent growth of literature in this area. The focus of this review article is to highlight the recent progress in aptamer-based biosensor development with emphasis on the integration between aptamers and the various forms of LOC devices including microfluidic chips and paper-based microfluidics. As aptamers are extremely versatile in terms of their utilization in different detection principles, a broad range of techniques are covered including electrochemical, optical, colorimetric, and gravimetric sensing as well as surface acoustics waves and transistor-based detection. 
    more » « less