skip to main content


Title: K-edge coded aperture optimization for uniform illumination in compressive spectral X-ray tomosynthesis

Compressive spectral X-ray imaging (CSXI) introduces a pixelated spectral modulator called K-edge coded aperture (KCA) in front of the X-ray source, which enables both, lower dosage to the subject, as well as the capability of spectral tomography while using low-cost integrating X-ray detectors. CSXI systems generally use hundreds of different spectral modulators, each with a distinct pattern to uniquely modulate the illumination at every view angle. In contrast, this paper introduces the use of a single and static coded aperture placed in a tomosynthesis gantry. The compressive system thus interrogates the subject with a fixed coded illumination pattern on all view angles. The advantages of the system are many including reduced cost and the feasibility of implementation. Given the reduced set of coded measurement and the limited spectral separation ability in the resulting architecture, the nonlinear inverse reconstruction problem results in a highly ill-posed problem. An efficient alternating minimization method with three-dimensional total variation regularization is developed for image reconstruction. Furthermore, rather than simply using a random pattern, the coded aperture is optimized under a uniform sensing criterion that shapes the spatial and spectral pattern of the coded aperture so as to minimize the overall radiation exposure placed on any volumetric area of the patient. This is of particular importance in medical imaging where patients at risk are recommended to have periodical X-ray tomosynthesis screenings. The coded aperture optimization is then posed as a binary programming problem solved by a gradient-based algorithm with equilibrium constraints. Numerical experiments show that spatial and spectral coding used in the proposed system to interrogate the subject not only reduces the radiation dose but it also improves the quality of image reconstruction. Gains close to 5dB in peak signal to noise ratio are observed in simulations. Furthermore, it is shown that the optimization of the KCA can effectively improve the uniformity of X-ray radiation compared to random KCA modulation, thus reducing the radiation dose throughout all volumetric sub-areas of the subject — an objective that is not possible with the use of random KCAs.

 
more » « less
Award ID(s):
1717578
PAR ID:
10303205
Author(s) / Creator(s):
; ; ; ;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Optics Express
Volume:
29
Issue:
25
ISSN:
1094-4087; OPEXFF
Format(s):
Medium: X Size: Article No. 41048
Size(s):
Article No. 41048
Sponsoring Org:
National Science Foundation
More Like this
  1. Coded aperture X-ray computed tomography is a computational imaging technique capable of reconstructing inner structures of an object from a reduced set of X-ray projection measurements. Coded apertures are placed in front of the X-ray sources from different views and thus significantly reduce the radiation dose. This paper introduces coded aperture X-ray computed tomography for robotic X-ray systems which offer positioning flexibility. While single coded-aperture 3D tomography was recently introduced for standard trajectory CT scanning, it is shown that significant gains in imaging performance can be attained by simple modifications in the CT scanning trajectories enabled by emerging dual robotic CT systems. In particular, the subject is fixed on a plane and the CT system uniformly rotates around ther −axis which is misaligned with the coordinate axes. A single stationary coded aperture is placed on front of the robotic X-ray source above the plane and the corresponding X-ray projections are measured by a two-dimensional detector on the second arm of the robotic system. The compressive measurements with misalignment enable the reconstruction of high-resolution three-dimensional volumetric images from the low-resolution coded projections on the detector at a sub-sampling rate. An efficient algorithm is proposed to generate the rotation matrix with two basic sub-matrices and thus the forward model is formulated. The stationary coded aperture is designed based on the Pearson product-moment correlation coefficient analysis and the direct binary search algorithm is used to obtain the optimized coded aperture. Simulations using simulated datasets show significant gains in reconstruction performance compared to conventional coded aperture CT systems.

     
    more » « less
  2. Static coded aperture x-ray tomography was introduced recently where a static illumination pattern is used to interrogate an object with a low radiation dose, from which an accurate 3D reconstruction of the object can be attained computationally. Rather than continuously switching the pattern of illumination with each view angle, as traditionally done, static code computed tomography (CT) places a single pattern for all views. The advantages are many, including the feasibility of practical implementation. This paper generalizes this powerful framework to develop single-scan dual-energy coded aperture spectral tomography that enables material characterization at a significantly reduced exposure level. Two sensing strategies are explored: rapid kV switching with a single-static block/unblock coded aperture, and coded apertures with non-uniform thickness. Both systems rely on coded illumination with a plurality of x-ray spectra created by kV switching or 3D coded apertures. The structured x-ray illumination is projected through the objects of interest and measured with standard x-ray energy integrating detectors. Then, based on the tensor representation of projection data, we develop an algorithm to estimate a full set of synthesized measurements that can be used with standard reconstruction algorithms to accurately recover the object in each energy channel. Simulation and experimental results demonstrate the effectiveness of the proposed cost-effective solution to attain material characterization in low-dose dual-energy CT.

     
    more » « less
  3. Traditional compressive X-ray tomosynthesis uses sequential illumination to interrogate the object, leading to long scanning time and image distortion due to the object variation. This paper proposes a single-snapshot compressive tomosynthesis imaging approach, where the object is simultaneously illuminated by multiple X-ray emitters equipped with coded apertures. Based on rank, intensity and sparsity prior models, a nonlinear image reconstruction framework is established. The coded aperture patterns are optimized based on uniform sensing criteria. Then, a modified split Bregman algorithm is developed to reconstruct the object from the set of nonlinear compressive measurements. It is shown that the proposed method can be used to reduce the inspection time and achieve robust reconstruction with respect to shape variation or motion of objects.

     
    more » « less
  4. Abstract: Coded aperture X-ray computed tomography (CT) has the potential to revolutionize X-ray tomography systems in medical imaging and air and rail transit security - both areas of global importance. It allows either a reduced set of measurements in X-ray CT without degrada- tion in image reconstruction, or measure multiplexed X-rays to simplify the sensing geometry. Measurement reduction is of particular interest in medical imaging to reduce radiation, and airport security often imposes practical constraints leading to limited angle geometries. Coded aperture compressive X-ray CT places a coded aperture pattern in front of the X-ray source in order to obtain patterned projections onto a detector. Compressive sensing (CS) reconstruction algorithms are then used to recover the image. To date, the coded illumination patterns used in conventional CT systems have been random. This paper addresses the code optimization prob- lem for general tomography imaging based on the point spread function (PSF) of the system, which is used as a measure of the sensing matrix quality which connects to the restricted isom- etry property (RIP) and coherence of the sensing matrix. The methods presented are general, simple to use, and can be easily extended to other imaging systems. Simulations are presented where the peak signal to noise ratios (PSNR) of the reconstructed images using optimized coded apertures exhibit significant gain over those attained by random coded apertures. Additionally, results using real X-ray tomography projections are presented. 
    more » « less
  5. Abstract: Coded aperture X-ray computed tomography (CT) has the potential to revolutionize X-ray tomography systems in medical imaging and air and rail transit security - both areas of global importance. It allows either a reduced set of measurements in X-ray CT without degrada- tion in image reconstruction, or measure multiplexed X-rays to simplify the sensing geometry. Measurement reduction is of particular interest in medical imaging to reduce radiation, and airport security often imposes practical constraints leading to limited angle geometries. Coded aperture compressive X-ray CT places a coded aperture pattern in front of the X-ray source in order to obtain patterned projections onto a detector. Compressive sensing (CS) reconstruction algorithms are then used to recover the image. To date, the coded illumination patterns used in conventional CT systems have been random. This paper addresses the code optimization prob- lem for general tomography imaging based on the point spread function (PSF) of the system, which is used as a measure of the sensing matrix quality which connects to the restricted isom- etry property (RIP) and coherence of the sensing matrix. The methods presented are general, simple to use, and can be easily extended to other imaging systems. Simulations are presented where the peak signal to noise ratios (PSNR) of the reconstructed images using optimized coded apertures exhibit significant gain over those attained by random coded apertures. Additionally, results using real X-ray tomography projections are presented. 
    more » « less