Abstract Tissue-engineered living machines is an emerging discipline that employs complex interactions between living cells and engineered scaffolds to self-assemble biohybrid systems for diverse scientific research and technological applications. Here, we report an adaptive, autonomous biohybrid pumping machine with flow loop feedback powered by engineered living muscles. The tissue is made from skeletal muscle cells (C2C12) and collagen I/Matrigel matrix, which self-assembles into a ring that compresses a soft hydrogel tube connected at both ends to a rigid fluidic platform. The muscle ring contracts in a repetitive fashion autonomously squeezing the tube, resulting in an impedance pump. The resulting flow is circulated back to the muscle ring forming a feedback loop, which allows the pump to respond to the cues received from the flow it generates and adaptively manage its pumping performances based on the feedback. The developed biohybrid pumping system may have broad utility and impact in health, medicine and bioengineering.more » « less
-
Pumps are critical life-sustaining components for all animals. At the earliest stages of life, the tubular embryonic heart works as a valveless pump capable of generating unidirectional blood flow. Inspired by this elementary pump, we developed an example of a biohybrid valveless pump-bot powered by engineered skeletal muscle. Our pump-bot consists of a soft hydrogel tube connected at both ends to a stiffer polydimethylsiloxane (PDMS) scaffold, creating an impedance mismatch. A contractile muscle ring wraps around the hydrogel tube at an off-center location, squeezing the tube with or without buckling it locally. Cyclic muscle contractions, spontaneous or electrically stimulated, further squeeze the tube, resulting in elastic waves that propagate along the soft tube and get reflected back at the soft/stiff tube boundaries. Asymmetric placement of muscle ring results in a time delay between the wave arrivals, thus establishing a net unidirectional fluid flow irrespective of whether the tube is buckled or not. Flow rates of up to 22.5 μL/min are achieved by the present pump-bot, which are at least three orders of magnitude higher than those from cardiomyocyte-powered valve pumps of similar size. Owning to its simple geometry, robustness, ease of fabrication, and high pumping performance, our pump-bot is particularly well-suited for a wide range of biomedical applications in microfluidics, drug delivery, biomedical devices, cardiovascular pumping system, and more.
-
The intriguing opportunities enabled by the use of living components in biological machines have spurred the development of a variety of muscle‐powered biohybrid robots in recent years. Among them, several generations of tissue‐engineered biohybrid walkers have been established as reliable platforms to study untethered locomotion. However, despite these advances, such technology is not mature yet, and major challenges remain. Herein, steps are taken to address two of them: the lack of systematic design approaches, common to biohybrid robotics in general, and in the case of biohybrid walkers specifically, the lack of maneuverability. A dual‐ring biobot is presented which is computationally designed and selected to exhibit robust forward motion and rotational steering. This dual‐ring biobot consists of two independent muscle actuators and a four‐legged scaffold asymmetric in the fore/aft direction. The integration of multiple muscles within its body architecture, combined with differential electrical stimulation, allows the robot to maneuver. The dual‐ring robot design is then fabricated and experimentally tested, confirming computational predictions and turning abilities. Overall, a design approach based on modeling, simulation, and fabrication exemplified in this versatile robot represents a route to efficiently engineer complex biological machines with adaptive functionalities.
-
Leveraging living muscle as an efficient and adaptive actuator for soft robots has been of increasing interest over the past decade, with a focus on proof‐of‐concept demonstrations of function. Reproducible design and scalable manufacturing of biohybrid machines requires methods to increase the stroke output of strain‐limited muscle actuators and enable accurate and precise quality control and performance monitoring. Compliant mechanical elements, termed flexures, are designed to enhance muscle contractile stroke to ≈5× previously reported values and decode contraction dynamics with high spatiotemporal resolution. Combining rigid and flexible elements within a linear elastic flexure enables us to outperform the sensitivity of gold standard elastomeric beam‐based measurements of muscle contraction at both low‐ and high‐frequency stimulations. Flexures are leveraged to make quantitative comparisons of force, work, and power outputs in muscle actuators, driving us to discover a new observation of frequency‐dependent fatigue in muscle, and also develop a novel method for tuning muscle contractile dynamics in a frequency‐independent manner. By enhancing the contractile stroke of muscle actuators and precisely tuning contractile dynamics and endurance with unprecedented precision, this study sets the stage for leveraging flexures to improve robust, reproducible, and predictive design and manufacturing of next‐generation biohybrid robots.
-
Tissue-on-chip systems represent promising platforms for monitoring and controlling tissue functions in vitro for various purposes in biomedical research. The two-dimensional (2D) layouts of these constructs constrain the types of interactions that can be studied and limit their relevance to three-dimensional (3D) tissues. The development of 3D electronic scaffolds and microphysiological devices with geometries and functions tailored to realistic 3D tissues has the potential to create important possibilities in advanced sensing and control. This study presents classes of compliant 3D frameworks that incorporate microscale strain sensors for high-sensitivity measurements of contractile forces of engineered optogenetic muscle tissue rings, supported by quantitative simulations. Compared with traditional approaches based on optical microscopy, these 3D mechanical frameworks and sensing systems can measure not only motions but also contractile forces with high accuracy and high temporal resolution. Results of active tension force measurements of engineered muscle rings under different stimulation conditions in long-term monitoring settings for over 5 wk and in response to various chemical and drug doses demonstrate the utility of such platforms in sensing and modulation of muscle and other tissues. Possibilities for applications range from drug screening and disease modeling to biohybrid robotic engineering.