Abstract Shortly after 0600 UTC (midnight local time) 9 June 2020, a convective line produced severe winds across parts of northeast Colorado that caused extensive damage, especially in the town of Akron. High-resolution observations showed gusts exceeding 50 m s−1, accompanied by extremely large pressure fluctuations, including a 5-hPa pressure surge in 19 s immediately following the strongest winds and a 15-hPa pressure drop in the following 3 min. Numerical simulations of this event (using the WRF Model) and with horizontally homogeneous initial conditions (using Cloud Model 1) reveal that the severe winds in this event were associated with gravity wave dynamics. In a very stable postfrontal environment, elevated convection initiated and led to a long-lived gravity wave. Strong low-level vertical wind shear supported the amplification and eventual breaking of this wave, resulting in at least two sequential strong downbursts. This wave-breaking mechanism is different from the usual downburst mechanism associated with negative buoyancy resulting from latent cooling. The model output reproduces key features of the high-resolution observations, including similar convective structures, large temperature and pressure fluctuations, and intense near-surface wind speeds. The findings of this study reveal a series of previously unexplored mesoscale and storm-scale processes that can result in destructive winds. Significance StatementDownbursts of intense wind can produce significant damage, as was the case on 9 June 2020 in Akron, Colorado. Past research on downbursts has shown that they occur when raindrops, graupel, and hail in thunderstorms evaporate and melt, cooling the air and causing it to sink rapidly. In this research, we used numerical models of the atmosphere, along with high-resolution observations, to show that the Akron downburst was different. Unlike typical lines of thunderstorms, those responsible for the Akron macroburst produced a wave in the atmosphere, which broke, resulting in rapidly sinking air and severe surface winds.
more »
« less
High-Resolution Observations of a Destructive Macroburst
Abstract Shortly after 0600 UTC (midnight MDT) on 9 June 2020, a rapidly intensifying and elongating convective system produced a macroburst and extensive damage in the town of Akron on Colorado’s eastern Plains. Instantaneous winds were measured as high as 51.12 m s −1 at 2.3 m AGL from an eddy covariance (EC) tower, and a 50.45 m s −1 wind gust from an adjacent 10-m tower became the highest official thunderstorm wind gust ever measured in Colorado. Synoptic-scale storm motion was southerly, but surface winds were northerly in a post-frontal airmass, creating strong vertical wind shear. Extremely high-resolution temporal and spatial observations allow for a unique look at pressure and temperature tendencies accompanying the macroburst and reveal intriguing wave structures in the outflow. At 10-Hz frequency, the EC tower recorded a 5-hPa pressure surge in 19 seconds immediately following the strongest winds, and a 15-hPa pressure drop in the following three minutes. Surface temperature also rose 1.5°C in less than one minute, concurrent with the maximum wind gusts, and then fell sharply by 3.5°C in the following minute. Shifting wind direction observations and an NWS damage survey are suggestive of both radial outflow and a gust front passage, and model proximity soundings reveal a well-mixed surface layer topped by a strong inversion and large low-level vertical wind shear. Despite the greatest risk of severe winds forecast to be northeast of Colorado, convection-allowing model forecasts from 6-18 h in advance did show similar structures to what occurred, warranting further simulations to investigate the unique mesoscale and misoscale features associated with the macroburst.
more »
« less
- Award ID(s):
- 1636663
- PAR ID:
- 10317336
- Date Published:
- Journal Name:
- Monthly Weather Review
- ISSN:
- 0027-0644
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Shortly after 0600 UTC (midnight local time) 9 June 2020, a convective line produced severe winds across parts of northeast Colorado that caused extensive damage, especially in the town of Akron. High-resolution observations showed gusts exceeding 50 m s−1, accompanied by extremely large pressure fluctuations, including a 5-hPa pressure surge in 19 s immediately following the strongest winds and a 15-hPa pressure drop in the following 3 min. Numerical simulations of this event (using the WRF Model) and with horizontally homogeneous initial conditions (using Cloud Model 1) reveal that the severe winds in this event were associated with gravity wave dynamics. In a very stable postfrontal environment, elevated convection initiated and led to a long-lived gravity wave. Strong low-level vertical wind shear supported the amplification and eventual breaking of this wave, resulting in at least two sequential strong downbursts. This wave-breaking mechanism is different from the usual downburst mechanism associated with negative buoyancy resulting from latent cooling. The model output reproduces key features of the high-resolution observations, including similar convective structures, large temperature and pressure fluctuations, and intense near-surface wind speeds. The findings of this study reveal a series of previously unexplored mesoscale and storm-scale processes that can result in destructive winds. Significance Statement Downbursts of intense wind can produce significant damage, as was the case on 9 June 2020 in Akron, Colorado. Past research on downbursts has shown that they occur when raindrops, graupel, and hail in thunderstorms evaporate and melt, cooling the air and causing it to sink rapidly. In this research, we used numerical models of the atmosphere, along with high-resolution observations, to show that the Akron downburst was different. Unlike typical lines of thunderstorms, those responsible for the Akron macroburst produced a wave in the atmosphere, which broke, resulting in rapidly sinking air and severe surface winds.more » « less
-
Abstract This study investigates whether the thermodynamics of supercell rear-flank outflow can be inferred from the propagation speed and vertical structure of the rear-flank gust front. To quantify the relationship between outflow thermodynamic deficit and gust front structure, CM1 is applied as a two-dimensional cold pool model to assess the vertical slope of cold pools of varying strength in different configurations of ambient shear. The model was run with both free-slip and semislip lower boundary conditions and the results were compared to observations of severe thunderstorm outflow captured by the Texas Tech University Ka-band mobile radars. Simulated cold pools in the free-slip model achieve the propagation speeds predicted by cold pool theory, while cold pool speeds in the semislip model propagate slower. Density current theory is applied to the observed cold pools and predicts the cold pool speed to within about 2 m s−1. Both the free-slip and semislip model results reveal that, in the same sheared flow, the edge of a strong cold pool is less inclined than that of a weaker cold pool. Also, a cold pool in weak ambient shear has a steeper slope than the same cold pool in stronger ambient shear. Nonlinear regressions performed on data from both models capture the proper dependence of slope on buoyancy and shear, but the free-slip model does not predict observed slopes within acceptable error, and the semislip model overpredicts the cold pool slope for all observed cases, but with uncertainty due to shear estimation.more » « less
-
We analyzed meteorological conditions that occurred during the December 2021 Boulder, Colorado, downslope windstorm. This event is of particular interest due to the ignition and spread of the Marshall Fire, which quickly became the most destructive wildfire in Colorado history. Observations indicated a rapid onset of fast winds with gusts as high as 51 m/s that generally remained confined to the east-facing slopes and foothills of the Rockies, similar to previous Boulder windstorms. After about 12 h, the windstorm shifted into a second, less intense phase. Midtropospheric winds above northwestern Colorado weakened prior to the onset of strong surface winds and the event strength started waning as stronger winds moved back into the area. Forecasts from NOAA high-resolution operational models initialized more than a few hours prior to windstorm onset did not simulate the start time, development rate and/or maximum strength of the windstorm correctly, and day-ahead runs even failed to develop strong downslope windstorms at all. Idealized modeling confirmed that predictability was limited by errors on the synoptic scale affecting the midtropospheric wind conditions representing the Boulder windstorm’s inflow environment. Gust forecasts for this event were critically evaluated.more » « less
-
{"Abstract":["As described in the methods section of “Direct Observation of Wave-coherent Pressure Work in the Atmospheric Boundary Layer”: Measurements were made from an open-lattice steel tower deployed in roughly 13 m water depth in Buzzards Bay, MA. Buzzards Bay is a 48 km by 12 km basin open on the SW side to Rhode Island Sound. The average depth is 11 m, with a tide range of 1 to 1.5 m, depending on the neap/spring cycles. Winds in Buzzards Bay are frequently aligned on the long-axis (from the NE or SW), and are commonly strong, particularly in the fall and winter. The tower was deployed near the center of the bay at 41.577638 N, 70.745555 W for a spring deployment lasting from April 12, 2022 to June 13th, 2022. Atmospheric measurements included three primary instrument booms that housed paired sonic anemometers (RM Young 81000RE) and high-resolution pressure sensors (Paros Scientific). The pressure sensor intakes were terminated with static pressure heads, which reduce the dynamic pressure contribution to the measured (static) pressure. The tower booms were aligned at 280 degrees such that the NE and SW winds would be unobstructed by the tower's main body. A fourth sonic anemometer (Gill R3) was extended above the tower such that it was open to all wind directions and clear of wake by the tower structure. A single point lidar (Riegl LD90-3i) was mounted to the highest boom, such that the lidar measured the water surface elevation underneath the anemometer and pressure sensors to within a few centimeters horizontally. All instruments were time synchronized with a custom "miniNode" flux logger, that aggregated the data streams from each instrument. Additional atmospheric and wave measurements on the tower included short-wave and long-wave radiometers (Kipp & Zonen), two RH/T sensors (Vaisala), and a standard lower-resolution barometer (Setra)."]}more » « less